2011 DC Electropumps Bull

Transkript

2011 DC Electropumps Bull
Ø 15
90±0.2
2011
DC Electropumps Bull
6,45
Rotation
3,5
5,7
www.hydronit.com
E-mail: [email protected]
Fax +39 0362 1841214
B010.10.01.00
Electro pumps Bull 80 series
MODEL CODE
EPB80
-
0,5 24DC /S150
-
K1,1 V**
Electro Pump
Bull 80 series
Gear pump
displacement (cc/rev)
(see tables E010.30.01):
Dc electric motor power (kW) and type
(see tables E010.20.01):
0,15 12DC (/T/S): 0,15kW 12VDC (/thermal switch/start switch)
0,15 24DC (/T/S): 0,15kW 24VDC (/thermal switch/start switch)
0,5 12DC (/T/S): 0,5kW 12VDC (/thermal switch/start switch)
0,5 24DC (/T/S): 0,5kW 24VDC (/thermal switch/start switch)
0,8 12DC (/T/S): 0,8kW 12VDC (/thermal switch/start switch)
0,8 12DC (/T/S): 0,8kW 24VDC (/thermal switch/start switch)
Optional Starting Switch:
(see tables E010.20.01):
/S150: 150 A starting switch (for Ø 80 motors)
Optional Relief Valve
(see tables E010.30.02):
V40
10÷40 bar
V110
20÷110 bar
V250
30÷250 bar
V350
70÷350 bar
K0,1
0,19
K0,2
0,26
K0,4
0,38
K0,6
0,63
K0,9
0,87
K1,2
1,2
K1,6
1,68
K2,1
2,19
K2,7
2,7
K3,2
3,26
B010.10.01.00
www.hydronit.com
E-mail: [email protected]
Fax +39 0362 1841214
B010.10.02.00
Electro pumps Bull 112 series
Option:
foot mounting
MODEL CODE
EPB114
-
2,2 24DC /S150
-
K1,1 V**
+
Electro Pump
Bull 114 series
E60543006
Option:
foot mounting
Gear pump
displacement (cc/rev)
(see tables E010.30.01):
Dc electric motor power (kW) and type
(see tables E010.20.02):
1,6 12DC (/T/S): 1,6kW 12VDC (/thermal switch/start switch)
2,1 12DC (/T/S): 2,1kW 12VDC (/thermal switch/start switch)
2,2 24DC (/T/S): 2,2kW 24VDC (/thermal switch/start switch)
Optional Starting Switch:
(see tables E010.20.02):
/S150: 150 A starting switch (for Ø 114 motors)
Optional Relief Valve
(see tables E010.30.02):
V40
10÷40 bar
V110
20÷110 bar
V250
30÷250 bar
V350
70÷350 bar
K0,9
0,87
K1,2
1,2
K1,6
1,68
K2,1
2,19
K2,7
2,7
K3,2
3,26
K3,7
3,8
K4,2
4,3
K5,0
4,9
K6,0
6,02
K7,9
6,02
B010.10.02.00
www.hydronit.com
E-mail: [email protected]
Fax +39 0362 1841214
B010.10.03.00
Electro pumps Bull 125 series
Option:
foot mounting
MODEL CODE
EPB125
-
2,4 12DC /S200
-
K3,7 V**
+
Electro Pump
Bull 125 series
E60543006
Option:
foot mounting
Gear pump
displacement (cc/rev)
(see tables E010.30.01):
Dc electric motor power (kW) and type
(see tables E010.20.03):
2,4 12DC (/T/S): 2,4kW 12VDC (/thermal switch/start switch)
3,0 24DC (/T/S): 3,0kW 24VDC (/thermal switch/start switch)
Optional Starting Switch:
(see tables E010.20.03):
/S200: 200 A starting switch (for Ø 125 motors)
Optional Relief Valve
(see tables E010.30.02):
V40
10÷40 bar
V110
20÷110 bar
V250
30÷250 bar
V350
70÷350 bar
K0,9
0,87
K1,2
1,2
K1,6
1,68
K2,1
2,19
K2,7
2,7
K3,2
3,26
K3,7
3,8
K4,2
4,3
K5,0
4,9
K6,0
6,02
K7,9
6,02
B010.10.03.00
www.hydronit.com
E-mail: [email protected]
Fax +39 0362 1841214
B010.10.04.00
Electro pumps Bull 151 series
MODEL CODE
EPB151
-
4,0HD 24DC /S200
-
K6,0 V**
+
Electro Pump
Bull 151 series
E60543006
Option:
foot mounting
Gear pump
displacement (cc/rev)
(see tables E010.30.01):
Dc electric motor power (kW) and type
(see tables E010.20.04):
2,5HD 12DC (/T/S): 2,5kW 12VDC (/thermal switch/start switch)
3,0HD 24DC (/T/S): 3,0kW 24VDC (/thermal switch/start switch)
4,0HD 24DC (/T/S): 3,0kW 24VDC (/thermal switch/start switch)
Optional Starting Switch:
(see tables E010.20.03):
/S200: 200 A starting switch (for Ø 151 motors)
Optional Relief Valve
(see tables E010.30.02):
V40
10÷40 bar
V110
20÷110 bar
V250
30÷250 bar
V350
70÷350 bar
K0,9
0,87
K1,2
1,2
K1,6
1,68
K2,1
2,19
K2,7
2,7
K3,2
3,26
K3,7
3,8
K4,2
4,3
K5,0
4,9
K6,0
6,02
K7,9
6,02
B010.10.04.00
www.hydronit.com
E-mail: [email protected]
Fax +39 0362 1841214
B010.20.01.00
EPB80 DC motors
Starting switch option
158
25,5
2,5
Protection degree: IP54
Insulation class: F
M6
6,5
Ø 16
Thermal protection option
Ø 63,45
Ø 80
Ø7
10,5
89,5
Rotation
Weight: 2,6 kg
Permanent magnets
Code
Description
Nominal
PPC
Spare part code
duty cycle
assembly code
500W 12V DC motor
0,5 12DC
M46C1S005
500W 24V DC motor
0,5 24DC
M46C2S005
800W 12V DC motor
0,8 12DC
M46C1S008
800W 24V DC motor
0,8 24DC
M46C2S008
150W 12V DC motor with thermal protection
0,15 12DC/T
M46C1ST01
150W 24V DC motor with thermal protection
0,15 24DC/T
M46C2ST01
500W 12V DC motor with thermal protection
0,5 12DC/T
M46C1ST05
500W 24V DC motor with thermal protection
0,5 24DC/T
M46C2ST05
800W 12V DC motor with thermal protection
0,8 12DC/T
M46C1ST08
800W 24V DC motor with thermal protection
0,8 24DC/T
M46C2ST08
S2: 6min
S3: 10% ED
S2: 6min
S3: 10% ED
S2: 3min
S3: 10% ED
S2: 4min
S3: 10% ED
S2: 10min
S3: 15% ED
S2: 10min
S3: 15% ED
S2: 6min
S3: 10% ED
S2: 6min
S3: 10% ED
S2: 3min
S3: 10% ED
S2: 4min
S3: 10% ED
Nominal Nominal
speed current
2800 rpm
90 A
2800 rpm
50 A
4000 rpm
130 A
4000 rpm
80 A
1400 rpm
30 A
1400 rpm
15 A
2800 rpm
90 A
2800 rpm
50 A
4000 rpm
130 A
4000 rpm
80 A
Options
Description
12 or 24V DC 150 Amp start switch + mounting kit
Remote wired control with two buttons
and 3m cable (see U040.40.03)
PPC
assembly code
S150 12DC 80
S150 24DC 80
Spare part code
P0201
M47SC0001 + M47SK0801 (12V DC)
M47SC0002 + M47SK0801(24V DC)
P0201 (single acting)
P0202
P0202 (double acting)
Notes: the starting switch mounting kit is provided when specifying the /S150 in EPB assembly code.
When ordering spare starting switches, it must be ordered separately (code: M47SK0801).
Coupling
Description
Coupling for Ø 80 DC motors and gr.1 pump
PPC
assembly code
Spare part code
Note: the coupling is already
included when specifying the
motor in EPB assembly code.
E36200007
Flange
Description
Flange for Ø 80 DC motors and gr.1 pump
PPC
assembly code
Spare part code
E10101010
Note: the flange is already
included when specifying
the motor in EPB assembly
code.
B010.20.01.00
www.hydronit.com
E-mail: [email protected]
Fax +39 0362 1841214
B010.20.02.00
EPB114 DC motors
Starting switch option
M8
Ø 114
Ø 42
Ø 98,4
12
Thermal protection option
Ø 15
90±0.2
Rotation
6,45
Compound wound
Protection degree: IP54
Insulation class: F
Weight: 7,05 kg
176
3,5
5,7
Code
PPC
assembly code Spare part code
Description
1600W 12V DC motor
1,6 12DC
M46C1S016
2200W 24V DC motor
2,2 24DC
M46C2S022
1600W 12V DC motor with thermal protection
1,6 12DC/T
M46C1ST16
2100W 12V DC motor with thermal protection
2,1 12DC/T
M46C1ST21
2200W 24V DC motor with thermal protection
2,2 24DC/T
M46C2ST22
Nominal
duty cycle
S2: 2min
S3: 7,5% ED
S2: 1,2min
S3: 4,5% ED
S2: 2min
S3: 7,5% ED
S2: 1,2min
S3: 7,5% ED
S2: 1,2min
S3: 4,5% ED
Nominal Nominal
speed current
2600 rpm 230 A
2600 rpm 140 A
2600 rpm 230 A
2300 rpm 330 A
2600 rpm 140 A
Options
Description
Starting switch 150A 12 or 24V DC + mounting kit
DC motors plastic cover
PPC
assembly code
S150 12DC 112
S150 24DC 112
M47SC0001 + M47SK1121 (12V DC)
M47SC0002 + M47SK1121(24V DC)
F16000001
F16000001
Spare part code
Notes: the starting switch mounting kit is provided when specifying the /S150 in EPB assembly code.
When ordering spare starting switches, it must be ordered separately (code: M47SK1121).
Coupling
PPC
assembly code
Description
Coupling for Ø114 - Ø125 DC motors and gr.1 pump
Note: the coupling is
Spare part code already included when
E36200003
specifying the motor in
EPB assembly code.
Flange
PPC
assembly code
Description
Flange for Ø114 - Ø125 DC motors and gr.1 pump
DC motors plastic cover
Note: the flange is already
Spare part code included when specifying
E10103010
the motor in EPB assembly
code.
Weight: 0,27 kg
203
127
180
Ø148
B010.20.02.00
www.hydronit.com
E-mail: [email protected]
Fax +39 0362 1841214
B010.20.03.00
EPB125 DC motors
4XM6
Ø 125
Ø 42
Ø 102
9
Ø 15
90°
Ø110
6,45
237
3,5
Compound wound
Protection degree: IP20
Insulation class: F
Weight: 11kg
5,7
Rotation
Code
Description
PPC
assembly code
2400W 12V DC motor with thermal protection & fan
2,4 12DC/T
3000W 24 V DC motor with thermal protection & fan
3 24DC/T
Nominal
Nominal Nominal
duty cycle
speed current
S2: 4min
M46C1ST24 S3: 7,5% ED 3400 rpm 290 A
S2: 4min
3500 rpm 170 A
M46C2ST30
S3: 7,5% ED
Spare part
code
Options
Description
Starting switch 200A 12 or 24V DC
PPC
assembly code
S200 12DC
S200 24DC
Spare part code
M47ZC0001 (12V DC)
M47ZC0002 (24V DC)
Coupling
Description
Coupling for Ø 112 and Ø125 DC motors
PPC
assembly code
Spare part code
E36200003
Note: the coupling is already included when specifying the motor in EPB assembly code.
Flange
Description
Flange for Ø 112 and Ø125 DC motors
PPC
assembly code
Spare part code
E10103010
Note: the flange is already included when specifying the motor in EPB assembly code.
B010.20.03.00
www.hydronit.com
E-mail: [email protected]
Fax +39 0362 1841214
B010.20.04.00
EPB151 DC motors with fan cooling
45°
N°
27
4M
51
Series wound
Protection degree: IP20
Insulation class: F
8
8
95
Ø162
Ø151
Ø151
Ø24 j6
45°
115
316
Rotation
Weight: 21,5 kg
Front attachment: B14-90
Code
Description
PPC
code
Spare part
code
Nominal Nominal Nominal Mounting
duty cycle speed current
kit
2500W 12V DC motor + thermal protection & fan 2,5HD 12DC/T MB14C1ST25 S2: 16min 1700 rpm
290 A
XB1490
3000W 24V DC motor + thermal protection & fan 3HD 24DC/T MB14C2ST30 S2: 16min 1700 rpm
170 A
XB1490
4000W 24V DC motor + thermal protection & fan 4HD 24DC/T MB14C2ST40 S2: 10min 2000 rpm
240 A
XB1490
Options
Description
Starting switch 200A 12 or 24V DC
PPC
assembly code
S200 12DC
S200 24DC
Spare part code
M47ZC0001 (12 V DC)
M47ZC0002 (24 V DC)
Coupling
Description
Two pieces coupling for Ø 151 DC motors
PPC
assembly code
Spare part code
E36100000 + E36100003
Note: the coupling is already included when specifying the motor in EPB assembly code.
Flange
Description
Flange for Ø 151 DC motors
PPC
assembly code
Spare part code
E10105010
Note: the flange is already included when specifying the motor in EPB assembly code.
Other B14 DC motors for heavy duty or special applications
They are available with Ø125, Ø151 or Ø191 in multiple executions, engineered to perform heavy duty cycles and tailor
made to suit each specific application, with or without fan cooling or thermal protection. They are mounted on the central
manifold with B14 standard mounting kits (see tables U040.40.11 and following).
To properly choose these motors, following minimum information must be provided to our technical office: 1) motor power
and voltage, 2) application type, 3) duty factors: S2 [min] continuous running time and S3 [%] percentage of running time
on total cycle time, 4) required motor speed, 5) quantity to be supplied.
B010.20.04.00
www.hydronit.com
E-mail: [email protected]
Fax +39 0362 1841214
B010.20.05.00
DC motors choice and electric connection schemes
DC motors choice
Once required pressure and flow and available voltage (12 or 24V DC) are known, you can select the motor checking on
each provided diagram if a pump displacement is available at the intersection of pressure and flow values. On the
relevant “I” curve you obtain the absorbed current. When the intersection point is not exactly on a pump curve, choose the
closer pump.
On the right hand diagram, from the current value, you can easily obtain the maximum allowed S2 (min) and S3 (%) values.
S2 gives the allowable motor continuous running time in minutes, S3 gives the allowable running time in % of the
total cycle.
If obtained S2 and S3 values are not enough for required duty cycle, choose a bigger motor and repeat the calculation on
the new motor curves.
240
12
,7)
I(3
11
,2
200
6)
9
,
I(2
)
,1
I(2
8
I(1
,6)
3,2
I(1
,1)
I(1
)
9
,
I(0
160
140
2,6
120
2,
100
1
80
4
1,6
3
1,3
60
1,1
0,9
40
2
0
25
50
75
100
125
150
175
200
P (bar)
Electric connection schemes
I (A)
5
S2
180
,3)
7
6
220
S3
)
3,7
10
1600 W 12V
I(3
Q (l/min)
Example:
For our application we have following data:
flow = 3 l/min, max pressure = 100 bar, not clearly defined duty cycle.
-We check on 1,6 Kw 12V DC motor diagram and see there is a pump available.
-We choose from curves 1,3 pump: a 1,3 cm3/rev pump. On the corresponding “I” curve we read 125 A absorbed current.
In these conditions on the S2 / S3 diagram we read that the DC motor can work for maximum 7 min (S2), that
is 17% (S3) of the total cycle, i.e. after 7 min working, the motor should cool down for at least 34 min.
-The total cycle time is calculated adding the working time and the idle time (17% working time plus 83% idle time),
in this case 41 min. If this duty cycle is not adequate for our application, we must choose a higher power DC motor and
check the relevant diagram again.
S2(min) 2
S3(%) 4
4
8
6
12
8
16
10
20
+
-
+
+
White
-
Thermal switch
+
-
+
-
12
24
MSV
Red
Starting switch
Red
+
Starting switch
-
Black
White
Remote control P0201
M
Single effect cylinder
Black
+
-
+
+
Directional
valve
Brown
+
-
Grey (up)
M
Thermal switch
Yellow/
Green
Black (down)
Starting switch
Remote control P0202
Double effect cylinder
M
B010.20.05.00
www.hydronit.com
E-mail: [email protected]
Fax +39 0362 1841214
B010.20.06.00
DC motors diagrams
EB46C2S005 500 W 24V
I (A)
100
0,
9)
1,
1)
,3)
4)
I(
0,
4
0,6
50
2
50
4)
0,
I(
,2)
9
0,
60
)
,6
0
I(
1,1
70
0,2
I(
60
I(
I(
0,6
80
)
2.5
I (1
5
)
I (0
,9)
I (1
,1)
90
0,9
3
70
1,3
1,1
3.5
I (A)
6
I(
EB46C1S005 500 W 12V
4
40
I (0
3
S3
S3
S2
S2
2
30
0,4
0,2
0,6
0.5
10
0
300
0
50
0
100
150
200
250
20
0,4
20
Q (l/min)
1
Q (l/min)
30
40
1.5
S2(min)
S3(%)
P (bar)
1
0,2
10
0
3
8
6
16
9
24
12
32
15
40
18
48
0
0
50
100
150
200
250
300
S2(min)
S3(%)
3
8
6
16
9
24
12
32
15
40
18
48
P (bar)
Test made with battery 135Ah 50% charged at 15°C and mineral oil ISO VG46 at 40°C
12
,3)
,1)
I(
0,
6)
I(
0,
9)
I (1,6
140
1)
9)
0,
I
I(
1,
1,3
I(
6)
,
(0
8
120
,4)
60
4)
0,
I(
1,3
50
,2)
I (0
I (0
1,
,2)
3
100
I (0
6
1
1,
6
70
)
I (1
,6)
10
1,6
1,6
8
I (1
,1)
I (2
160
I(
2,1
10
80
)
180
12
I (A)
EB46C2S008 800 W 24V
I (A)
I (1
EB46C1S008 800 W 12V
40
1,
1
80
30
60
4
S2
0,9
0,2
20
0
0
0
50
100
20
40
0,4
150
200
Q (l/min)
Q (l/min)
0,6
2
S2(min)
300
250
S3(%)
P (bar)
2
4
4
8
6
12
S3
4
S3
0,9
8
16
10
20
0,6
2
0,4
0
12
24
0
50
100
150
200
S2
10
0,2
0
300
250
S2(min)
S3(%)
P (bar)
2
4
4
8
6
12
8
16
10
20
12
24
Test made with battery 135Ah 50% charged at 15°C and mineral oil ISO VG46 at 40°C
300
)
2,
1
I(
I(
1
I(
)
1
1,
I(
9)
I(
3
I ( ,7)
3,
2)
2)
12
S3
250
,
I (0
4,
)
I(
3,2
2, )
6)
3,7
I(
2
3, ,6
2
I(
)
,3
6
2,
)
6
1,
I (A)
160
14
4,2 3,7 ,2
3
7
3,
9
EB46C2S022 2200 W 24V
I (A)
I(
EB46C1S016 1600 W 12V
12
140
6)
2,
I(
10
)
1,6
I(
S3
120
,3)
I (1
I
1)
(1,
100
S2
1
2,
2,1
200
)
,1
2
I(
8
150
6
80
6
60
S2
100
1,6
1,6
4
3
40
Q (l/min)
1,3
1,3
Q (l/min)
50
1,1
0,9
0
0
50
100
150
P (bar)
200
250
0
300
S2(min) 2
S3(%) 4
4
8
6
12
8
16
10
20
12
24
1,1
2
20
0,9
0
0
50
100
150
200
250
0
300
P (bar)
S2(min) 2,5
S3(%) 4
5
8
7,5
12
10
16
12,5
20
15
24
Test made with battery 135Ah 50% charged at 15°C and mineral oil ISO VG46 at 40°C
B010.20.06.00
www.hydronit.com
E-mail: [email protected]
Fax +39 0362 1841214
B010.20.07.00
DC motors diagrams
EB46C1ST24 2400 W 12V
I (A)
1)
2,
I(
I(
I(
I(
6
2,
1,
I(
I(
,9
I (0
I(
1,
I(
I(
2,
1
I(
I (A)
300
)
,3
1)
1,
I(
9)
0,
I(
12
S3
300
)
)
1
1,
3)
6)
3,2
3,7
)
3,2
)
2,
6)
2
I(
3,
3,2
)
6)
7
9
)
6
1,
1)
14
2,
3,
360
I(
EB46C1ST21 2100 W 12V
12
250
1
2,
10
240
200
8
2,6
180
6
150
1,6
1,6
S2
120
0
300
0
100
150
200
Q (l/min)
Q (l/min)
60
0,9
50
1,1
0,9
1,1
0
S2
100
1,3
4
1,3
3
S3
2,1
6
250
S2(min) 2
S3(%) 4
P (bar)
50
2
0
0
4
8
6
12
8
16
10
20
12
24
0
50
100
150
P (bar)
200
250
S2(min)
3
6
S3(%)
6
12
9
18
12
24
15
30
18
36
Test made with battery 135Ah 50% charged at 15°C and mineral oil ISO VG46 at 40°C
I (A)
S3
4,
9
160
140
S2
150
Q (l/min)
Q (l/min)
S2
100
2)
4,
I(
4,
I(
40
0
100
4,2
3,7
20
50
150
4
60
1,6
200
4,9
80
5
0
I (1
6
2,6
2,1
S3
,3)
100
10
250
,6)
I (1
120
3,2
300
2,
I(
I(
3,2
,1
2,6 2
15
6)
7) 2)
3, I (3, I (2,
1)
10
8
3,7
I(
180
4,2
6,
0)
4,
I ( 2)
3,
7)
I(
3,
2)
I(
2,
6)
I(
,0)
,9)
I (6
I (4
)
,6
1
I(
6,0
6,0
20
)
,1
2
I(
I (A)
EB14C1ST25 2500 W 12V HD
12
200
9)
EB46C2ST30 3000 W 24V
25
0
250 S2(min) 2
200
P (bar)
S3(%)
4
2
50
1,6
1,3
0
4
8
6
12
8
16
10
20
12
24
0
0
50
100
150
200
250
300
P (bar)
S2(min) 5
10
15
20
25
30
S3(%)
25
30
35
40
45
20
4,9
140
S3
9)
4,
I(
0)
6,
I (7
,9)
16
I(
2)
3,
7)
I(
4,
I(
I(
I(
,9)
I (7
0
4,9
18
160
6,
6,0
14
6)
2,
I(
I (A)
300
9
7,9
16
2)
3,
I(
EB14C2ST40 4000 W 24V HD
20
7,
18
4,
9)
I (A)
180
20
6,
EB14C2ST30 3000 W 24V HD
0)
Test made with battery 135Ah 50% charged at 15°C and mineral oil ISO VG46 at 40°C
2)
4,
I(
7)
3,
I(
2)
3,
I(
250
14
200
120
S3
12
12
100
S2
150
10
10
80
8
8
Q (l/min)
3,2
2,6
40
20
2
100
150
P (bar)
200
250
300
100
3,7
S2(min) 5
S3(%) 8
10
16
15
24
20
32
25
40
30
48
3,2
4
50
2
0
0
0
50
4,2
6
4
0
S2
60
Q (l/min)
4,2
3,7
6
0
50
100
150
200
250
0
300
P (bar)
S2(min)
S3(%)
5
6
10
12
15
18
20
24
25
30
30
36
Test made with battery 135Ah 50% charged at 15°C and mineral oil ISO VG46 at 40°C
B010.20.07.00
www.hydronit.com
E-mail: [email protected]
Fax +39 0362 1841214
B010.30.01.00
Gr.0 gear pumps
50
16
n.2 Ø 5,5
5,5
9,6
Ø8
55
Ø 22
N
1/4’’BSPP
9,5
5
Alluminium adapter flange for group 0
Code: E60513025
n.2 Ø 8,5
n.2 M5
Weight: 0,08 Kg
Spare part code
PPC assembly code field
E6050 ** **
K
Size:
see spare part code
on below table
Pump type:
K = K type with front/rear ports
KL = KL type with lateral ports
Nominal displacement:
(cc/rev) see below table
0,6
Ports:
40 = front/rear ports
42 = lateral ports
Available range
Nominal
Peak
Intermittent Continuous
Max speed
N
Displacement pressure pressure
pressure
(rpm)
(mm)
(cc/rev)
(bar)
(bar)
(bar)
Bolts*
(mm)
Spare part
code
Weight
0,26
200
180
160
6000
45,5
M5x55
E60504202
0,33 Kg
180
160
6000
47,5
M5x55
E60504204
0,35 Kg
160
6000
51,5
M5x60
E60504206
0,40 Kg
0,4
200
0,6
200
180
0,9
200
180
160
5000
52,5
M5x65
E60604201
0,44 Kg
1,2
200
180
160
3900
55,5
M5x65
E60604202
0,49 Kg
1,5
200
180
160
3900
57,8
M5x70
E60604235
0,51 Kg
Other pumps executions with different pressure/speed ratings are available on request.
* A proper washer is to be forecast to adapt bolt lenght
Main features
Oil temperature
Inlet pressure
Fixing bolts
-15 ÷ +80 °C
0,7 < P < 3,0 bar (absolute pressure)
2 x M8 8.8 class steel
tightening torque: 25 Nm
Peak pressure: cycle 2 s ON
Pressure definition Intermittent pressure: cycle 20 s ON
Continuous pressure: cycle always ON
Filtration setting
25 ÷ 50 µ
B010.30.01.00
www.hydronit.com
E-mail: [email protected]
Fax +39 0362 1841214
B010.30.02.00
Gr.1 gear pumps
12
8
69
5
23
N
9,5
Ø 10
71
Ø 32
n.2 Ø 8,6
Option: relief valve
3/8’’ BSPP (KL type)
Spare part code
PPC assembly code field
E6060 ** **
K
Size:
see spare part code
on below table
Pump type:
K = K type
KL = KL type with lateral ports
Nominal displacement:
(cc/rev) see below table
1,2
Ports:
40 = front/rear ports
42 = lateral ports
Optional relief valve:
(bar) see table E010.30.03
V**
Available range
Nominal
Peak
Intermittent Continuous
Max speed
N
Displacement pressure pressure
pressure
(rpm)
(mm)
(cc/rev)
(bar)
(bar)
(bar)
Bolts*
(mm)
Spare part
code
Weight
0,8
250
220
200
5000
61
M8x75
250
220
200
5000
62
M8x75
E6060**01
E6060**02
0,77 Kg
1,2
1,6
250
220
200
5000
64
M8x75
E6060**35
0,80 Kg
2,1
250
220
200
5000
66
M8x80
0,82 Kg
2,6
250
220
200
5000
68
M8x80
E6060**04
E6060**05
3,2
250
220
200
4500
70
M8x85
E6060**06
0,87 Kg
3,7
230
200
180
4000
72
M8x85
E6060**07
0,90 Kg
4,2
230
180
3800
74
M8x90
E6060**08
0,92 Kg
170
3200
76
M8x90
E6060**09
0,95 Kg
160
3000
88
M8x100
E6060**10
1 Kg
4,9
220
200
190
6,0
220
190
0,77 Kg
0,85 Kg
Other pumps executions with different pressure/speed ratings are available on request.
* Proper washers are to be forecast to adapt bolt lenght
Main features
Oil temperature
Inlet pressure
Fixing bolts
-15 ÷ +80 °C
0,7 < P < 3,0 bar (absolute pressure)
2 x M8 8.8 class steel
tightening torque: 25 Nm
Peak pressure: cycle 2 s ON
Pressure definition Intermittent pressure: cycle 20 s ON
Continuous pressure: cycle always ON
Filtration setting
25 ÷ 50 µ
B010.30.02.00
www.hydronit.com
E-mail: [email protected]
Fax +39 0362 1841214
B010.30.03.00
Accessories
VMDC20
25,5 max
38
ø 25
2
ø 12,7
3/4 16 UNF - 2A
26,5
P
1
T
Hex. 22
Hex. 10
Hex. 3
Spare part code
Hydraulic symbol
P
VMDC
Direct acting
relief valve
20
Nominal size:
20 = 20 l/min
B
Working range:
A = 10 ÷ 40 bar
B = 20 ÷ 110 bar
C = 30 ÷ 250 bar
D = 70 ÷ 350 bar
Main features
Adjusting device:
1 = screw (std)
2 = handwheel
Series
1
01
T
Max pressure
350 bar
Max flow
20 l/min
Weight
0,15 kg
Recommended tightening torque: 40 Nm
Recommended filtration settings: 25 ÷ 50 µ
Oil temperature: -30 ÷ + 80 °C
Foot mounting support
140
124
140
E60543006
Weight: 0,4 Kg
82
45
Ø8,5 - n. 4
ø11 - n. 2
Spare part codes
124
E60543006
B010.30.03.00

Podobné dokumenty

section d

section d 1,2l cylindrical steel horizontal mounting tank + 3/8"BSPP std filler & breather plug

Více

do 28.února 2015

do 28.února 2015 Extra-široké otevření, širší o 28% až 70% než ostatní podobné kleště: jedny kleště nahradí několik (spoří hmotnost a místo v kufru s nářadím). obj.č. 018202 otevření 35 mm obj.č. 018208 otevření 56...

Více

ACO - Mostní odvodnění

ACO - Mostní odvodnění vario normal vario normal Vario normal vario normal vario

Více

JPT-100 - uživatelský manuál pro krytou větrnou

JPT-100 - uživatelský manuál pro krytou větrnou kladné napětí, černé – záporné napětí) a připevněte větrnou turbínu na sloup pomocí upevňovacích prvků. (Obr. 20)

Více