wind load testing according to en 16002:2010
Transkript
wind load testing according to en 16002:2010
1 Wind load testing according to en 16002:2010 www.constructech.se [email protected] Complete service WIND LOAD TESTING ACCORDING TO EN 16002:2010 Determination of the resistance to wind load of mechanically fastened flexible sheets for roof waterproofing NEW LARGER WIND LOAD TESTER! CONSTRUCTECH – AN INDEPENDENT PARTNER IN WIND LOAD TESTING We offer our costumers testing and development in a secure environment with access to suitable testing equipment and a complete workshop. Our full size wind load chamber is equipped with the most modern control system in the industry. We perform wind uplift testing according to ETAG-006/EN-16002:2010 and FM-4470 or according to customer demands. Client Constructech Sweden AB SINTEF Building and Infrastructu re Oslo Forskningsveien 3b, 0373 Oslo P.O.Box 124 Blindern, 0314 Oslo Telephone: 22 96 55 55 Telefax: 22 69 94 38 Client's address Malmbyvägen 4 S-645 94 Strängnäs Sverige Trondheim Høgskoleringen 7b 7465 Trondheim Telephone: 73 59 33 90 Telefax: 73 59 33 80 Client’s contact-person Fredrik Rundgren E-mail: [email protected] Internet: www.sintef.no/byggforsk Enterprise No: NO 948 007 029 MVA Project/archive no. 3D0686.01 Date 25.05.2009 Project leader Sign. Knut Noreng Rev. date No. of pages Appendixes 5 Responsible manager Lisbeth Alnes Sign. Noralf Bakken Inspection report Inspection carried out according to Contact-person(s) in the company Fredrik Rundgren Author(s) Knut Noreng Noralf Bakken Accredited as inspection body Initial inspection carried out at Constructech Sweden AB - May 2009 Internal quality manual EOTA ETAG 006, chapter 5.1.4.1 (Levels for quality assurance according to ISO 9001) Approved by notified body Classification Restricted SQuality assurance INSP 019 Date of inspection 07.05.2009 Inspector(s) Knut Noreng Noralf Bakken Phone no. (+46) 152-331930 Fax no. Constructech has signed an inspection and control agreement with Sintef, notified body in Norway, resulting in continuous control of the quality management system and test equipment. Intron Certificatie B.V, notified body Netherlands, has performed an audit and accepts wind load tests according to EN-16002:2010 performed by Constructech. (+46) 152-331939 E-mail [email protected] Brief summary Inspection of the quality system and the windload tester at Constructech Sweden AB have been carried out successfully, and our overall impression of the and is planned to be continuously improved. company is good. The internal quality system is well documented No deviations were found during the inspection. Two observations which can be improved are mentioned in the report. In addition, there are some routines which are not mentioned in the quality the employees and complaints from manual so far, such as training of customers. However, Constructech Sweden AB is a relatively new established company with few employees. Complaints from customers and training of employees been any issue. have therefore up till now not Activity code Keywords Wind load tester Internal quality Filename 3D0686.01 Rapport Constructech Sweden AB.doc Excerpts or summary quotes from this report are only permitted with the explicit approval of SINTEF. If a translation of the report is required, SINTEF reserved the rights to approve the translation. All costs will be charged to the client. Sintef is notified body in Norway within testing and approvals. Customer service Windload testing and project management We have a full range of hot air seam welders both automatic and handheld, for our customers to use. Our test engineer assists during the installation or execute the complete installation of the test roof if this is preferred by the customer. Calculations according Eurocode EN 1991-1-4 The result from the wind load test according to EN 16002:2010 is the base for the design load of a roof system. Our latest software Roof Calculator assists the customer to perform wind load calculations on flat and pitched roofs throughout Europe according to EN 1991-1-4 with the NA for each country in consideration. www.roofcalculator.eu We assist our customers within test and approval projects for optimal performance of the roof system. 3 Wind load testing according to en 16002:2010 www.constructech.se [email protected] One of the industry´s most modern control system visualizing the test FIXING PATTERNS FOR DIFFERENT MEMBRANE WIDTHS CONSTRUCTECH NEW WINDLOAD TESTER Dimensions of wind load tester 4,90 x2.65m Substrate Steel 0,75mm, S-350 Distance between steel ribs 320mm Insulation 100mm Mineral wool Type Cover width (mm) Fasteners in one row Number of rows Factor Ca Factor Cd Membrane 1,0m 880 8 6 1,0 1,0 Membrane 1,05m 930 8 5 1,0 1,0 Membrane 1,32m 1200 8 4 1,0 1,0 Membrane 1,50m 1380 8 4 1,0 1,0 Membrane 1,60m 1480 8 4 1,0 1,0 Membrane 2,0m 1880 8 3 0,95 0,90 Membrane 2,10m 1980 8 3 0,94 0,90 Test model drawings for each membrane width; page 4-10 4 Wind load testing according to en 16002:2010 www.constructech.se [email protected] FIXING PATTERN 1,0 M WIDE MEMBRANE Dimensions of wind load tester 4,90 x2.65m Substrate Steel 0,75mm, S-350 Distance between steel ribs 320mm Insulation 100mm Mineral wool Wind load testing according to en 16002:2010 www.constructech.se [email protected] FIXING PATTERN 1,05 M WIDE MEMBRANE Dimensions of wind load tester 4,90 x2.65m Substrate Steel 0,75mm, S-350 Distance between steel ribs 320mm Insulation 100mm Mineral wool 5 6 Wind load testing according to en 16002:2010 www.constructech.se [email protected] FIXING PATTERN 1,32 M WIDE MEMBRANE Dimensions of wind load tester 4,90 x2.65m Substrate Steel 0,75mm, S-350 Distance between steel ribs 320mm Insulation 100mm Mineral wool Wind load testing according to en 16002:2010 www.constructech.se [email protected] FIXING PATTERN 1,5 M WIDE MEMBRANE Dimensions of wind load tester 4,90 x2.65m Substrate Steel 0,75mm, S-350 Distance between steel ribs 320mm Insulation 100mm Mineral wool 7 8 Wind load testing according to en 16002:2010 www.constructech.se [email protected] FIXING PATTERN 1,6 M WIDE MEMBRANE Dimensions of wind load tester 4,90 x2.65m Substrate Steel 0,75mm, S-350 Distance between steel ribs 320mm Insulation 100mm Mineral wool Wind load testing according to en 16002:2010 www.constructech.se [email protected] FIXING PATTERN 2,0 M WIDE MEMBRANE Dimensions of wind load tester 4,90 x2.65m Substrate Steel 0,75mm, S-350 Distance between steel ribs 320mm Insulation 100mm Mineral wool 9 10 Wind load testing according to en 16002:2010 www.constructech.se [email protected] FIXING PATTERN 2,1 M WIDE MEMBRANE Dimensions of wind load tester 4,90 x2.65m Substrate Steel 0,75mm, S-350 Distance between steel ribs 320mm Insulation 100mm Mineral wool 12 Wind load testing according to en 16002:2010 www.constructech.se [email protected] Constructech is a Swedish company providing project management, material testing and development for the construction industry. Customer/technical support Phone: +46 152 33 19 30 E-mail: [email protected] www.constructech.se Constructech Sweden AB, Malmbyvägen 4, SE-645 47 Strängnäs, Sweden. Phone: +46 152 33 19 30. E-mail: [email protected] www.constructech.se