Air cooled chiller portfolio

Transkript

Air cooled chiller portfolio
Aplikované
systémy
Ceník
2014
→ Table of contents
Type
Refrigerant
Compressor
Capacity
Page
Air cooled chiller Inverter
R-410A
Swing
EWAQ-A
Material
5-13 kW
3
Air cooled heat pump Inverter
R-410A
Swing
EWYQ-A
5-13 kW
4
Air cooled chiller Inverter
R-410A
Scroll
EWAQ-BAW
17-75 kW
5
Air cooled heat pump Inverter
R-410A
Scroll
EWYQ-BAW
17-75 kW
5
Air cooled chiller
R-407C
Scroll
EUWA-KBZW
11-55 kW
6
Air cooled heat pump
R-407C
Scroll
EUWY-KBZW
12-54 kW
7
Air cooled chiller
R-410A
Scroll
EWAQ-DAYN
80-252 kW
8
Air cooled heat pump
R-410A
Scroll
EWYQ-DAYN
88-283 kW
9
Water cooled chiller
R-407C
Scroll
EWWP-KBW1N
13-65 kW
10
Water cooled chiller
R-407C
Scroll
EWWP-KAW1M
86-194 kW
11
Condenserless chiller
R-407C
Scroll
EWLP-KBW1N
12-62 kW
12
Condensing unit heat pump Inverter
R-410A
Scroll
ERQ
11-28 kW
Hydronic Kit
EKBT / EHMC
13
14
Rooftop heat pump
R-410A
Scroll
UATYQ-CY1
27-73 kW
14
Rooftop heat pump
R-407C
Scroll
UATYP-AY1
79-110 kW
14
FWE-C
2,1 - 10 kW
15
Fan coil
Low ESP duct
Medium ESP duct
FWB-B
2,6 - 11 kW
16
Medium ESP duct / BLDC
FWP-A
2,6 – 6,5 kW
17
High ESP flexi duct
FWD-A
3,9 - 18 kW
18
Cassette 600x600
FWF-C
2,5 - 4,5 kW
19
Cassette 600x600
FWF-B
1,7 - 4 kW
19
Cassette 900x900
FWC-B
5 - 7,2 kW
19
Wall mounted
FWT-C
2,3 - 5,3 kW
20
Floor standing
FWV-D
1,5 - 8 kW
22
Flexi type
FWL-D
1,5 - 8 kW
23
Flexi concealed
FWM-D
1,5 - 8 kW
24
Floor standing / BLDC
FWZ-A
2,6 - 10 kW
26
Flexi type / BLDC
FWR-A
2,6 - 10 kW
27
Flexi concealed / BLDC
FWS-A
2,6 - 10 kW
28
Overview: Air cooled chiller portfolio
30
Overview: Portfolio Water cooled and Condenserless units
32
Large Chillers options and accessories summary
32
Air Cooler
34
Air Handling Unit
34
Dry Cooler & Condenser
34
Cooling Tower
34
Compressor Service
Screw/Recip
34
Measuring conditions
34
Commercial terms and conditions
35
▪ NOTES
The pricelist is valid from 1. April 2014. All prior pricelists are not valid anymore. All prices are list prices in Euro and excl. VAT.
The Daikin Commercial Terms and Conditions apply (see last page or http://www.daikin-ce.com).
We reserve the right for printing errors and model changes.
2
→ EWAQ-A
▪ EWAQ-A
AIR COOLED CHILLER INVERTER
High ESEER thanks to inverter technology, integrated hydronics.
Unit size (1 phase)
Price
Cooling capacity
EER
ESEER
Sound power level
EWAQ005ADVP
EWAQ006ADVP
EWAQ007ADVP
dB(A)
77.996,–
5,2
2,75
3,75
62
85.392,–
6
2,55
3,83
62
94.734,–
7,1
2,41
3,87
63
CZK
11.660,–
11.660,–
11.660,–
EWAQ009ACV3P
EWAQ010ACV3P
EWAQ011ACV3P
dB(A)
108.087,–
8,6
3,05
4,31
64
114.438,–
9,6
2,93
4,3
64
122.907,–
11,1
2,85
4,33
64
CZK
CZK
CZK
12.904,–
on request
3.588,–
12.904,–
on request
3.588,–
12.904,–
on request
3.588,–
EWAQ009ACW1P
EWAQ011ACW1P
EWAQ013ACW1P
dB(A)
112.745,–
9,1
2,99
4,43
64
123.979,–
11,1
2,85
4,44
64
131.405,–
13,3
2,57
4,36
66
CZK
CZK
CZK
12.904,–
on request
3.588,–
12.904,–
on request
3.588,–
12.904,–
on request
3.588,–
CZK
kW
Options
OP10
evaporator heater tape
Unit size (1 phase)
Price
Cooling capacity
EER
ESEER
Sound power level
CZK
kW
Options
OP10
SOPHP
EKRP1HBA
evaporator heater tape
high ESP pump (up to 90 kPa)
digital I/0 PCB
Unit size (3 phase)
Price
Cooling capacity
EER
ESEER
Sound power level
CZK
kW
Options
OP10
SOPHP
EKRP1HBA
evaporator heater tape
high ESP pump (up to 90 kPa)
digital I/0 PCB
3
→ EWYQ-A
▪ EWYQ-A
AIR COOLED HEAT PUMP INVERTER
Wide operation range - ambient temperature in heating down to -15°C.
Unit size (1 phase)
Price
Cooling capacity
EER
Heating capacity
COP
Sound power level
EWYQ005ADVP
EWYQ006ADVP
EWYQ007ADVP
dB(A)
90.077,–
5,2
2,75
5,65
2,87
62
97.275,–
6
2,55
6,35
2,83
62
103.910,–
7,1
2,41
7,75
2,74
63
CZK
11.660,–
11.660,–
11.660,–
EWYQ009ACV3P
EWYQ010ACV3P
EWYQ011ACV3P
dB(A)
124.403,–
8,6
3,05
4,31
9,9
3,3
64
130.953,–
9,6
2,93
4,3
11,4
3,29
64
138.801,–
11,1
2,85
4,33
12,9
3,27
64
CZK
CZK
CZK
12.904,–
on request
3.588,–
12.904,–
on request
3.588,–
12.904,–
on request
3.588,–
EWYQ009ACW1P
EWYQ011ACW1P
EWYQ013ACW1P
dB(A)
129.258,–
9,1
2,99
4,43
10,9
3,28
64
140.296,–
11,1
2,85
4,44
12,4
3,27
64
148.342,–
13,3
2,57
4,36
13,9
3,25
66
CZK
CZK
CZK
12.904,–
on request
3.588,–
12.904,–
on request
3.588,–
12.904,–
on request
3.588,–
CZK
kW
kW
Options
OP10
evaporator heater tape
Unit size (1 phase)
Price
Cooling capacity
EER
ESEER
Heating capacity
COP
Sound power level
CZK
kW
kW
Options
OP10
SOPHP
EKRP1HBA
evaporator heater tape
high ESP pump (up to 90 kPa)
digital I/0 PCB
Unit size (3 phase)
Price
Cooling capacity
EER
ESEER
Heating capacity
COP
Sound power level
CZK
kW
kW
Options
OP10
SOPHP
EKRP1HBA
evaporator heater tape
high ESP pump (up to 90 kPa)
digital I/0 PCB
4
→ EWAQ-BAW, EWYQ-BAW
▪ EWAQ-BAW
AIR COOLED CHILLER INVERTER
High efficiency with leader-of-class ESEER.
No buffer tank required for standard applications.
Unit size
EWAQ016BAW EWAQ021BAW EWAQ025BAW EWAQ032BAW EWAQ040BAW EWAQ050BAW EWAQ064BAW
Price
Cooling capacity (nominal) EWAQ - BAWN / BAWP
ESEER EWAQ - BAWN / BAWP
Sound power level
CZK
kW
dB(A)
187.494,–
17,4 / 16,6
4,33 / 4,21
78
220.797,–
21,7 / 20,7
4,08 / 4,18
78
249.008,–
25,8 / 24,7
3,85 / 4,04
78
287.287,–
32,3 / 30,9
3,39 / 3,62
80
380.080,–
43,4 / 41,5
4,19 / 4,24
81
423.394,–
51,8 / 49,7
3,96 / 4,12
81
488.902,–
64,5 / 62,3
3,64 / 3,78
83
CZK
CZK
CZK
CZK
15.133,–
16.810,–
24.653,–
11.198,–
15.133,–
16.810,–
24.653,–
11.198,–
15.133,–
16.810,–
24.653,–
11.198,–
15.133,–
20.500,–
24.653,–
11.198,–
17.716,–
20.500,–
30.064,–
13.656,–
17.716,–
20.500,–
30.064,–
13.656,–
17.716,–
20.500,–
30.064,–
13.656,–
Options
OP10
OPSP
OPHP
OPZL
Evaporator electric heater
One centrifugal pump (low lift)
One centrifugal pump (high lift)
Low leaving water operation down to -10 °C
Kit
Demand PCB Remote:
On/Off, Cool/heat, thermo On/Off
EKRUAHT
Additional remote user interface
BHGP26A1 Digital pressure gauges
External adaptor for:
DTA104A62
Demand and Low noise control
RTD-W
Modbus interface
EKRP1AHT
CZK
3.993,–
3.993,–
3.993,–
3.993,–
7.986,–
7.986,–
7.986,–
CZK
CZK
5.932,–
14.583,–
5.932,–
14.583,–
5.932,–
14.583,–
5.932,–
14.583,–
5.932,–
29.166,–
5.932,–
29.166,–
5.932,–
29.166,–
CZK
12.210,–
12.210,–
12.210,–
12.210,–
24.420,–
24.420,–
24.420,–
CZK
10.272,–
10.272,–
10.272,–
10.272,–
10.272,–
10.272,–
10.272,–
▪ EWYQ-BAW
AIR COOLED HEAT PUMP INVERTER
Wide operation range - ambient temperature in heating down to -15°C.
Unit size
EWYQ016BAW EWYQ021BAW EWYQ025BAW EWYQ032BAW EWYQ040BAW EWYQ050BAW EWYQ064BAW
Price
Cooling capacity (nominal) EWYQ - BAWN / BAWP
ESEER EWYQ - BAWN / BAWP
Heating capacity (nominal) EWYQ - BAWN / BAWP
COP EWYQ - BAWN / BAWP
Sound power level
CZK
kW
dB(A)
215.618,–
17,4 / 16,6
4,33 / 4,21
16,2 / 17,0
2,93 / 2,97
78
253.955,–
21,7 / 20,7
4,08 / 4,18
20,3 / 21,3
2,86 / 2,86
78
286.391,–
25,8 / 24,7
3,85 / 4,04
24,6 / 25,7
2,76 / 2,75
80
330.429,–
32,3 / 30,9
3,39 / 3,62
30,7 / 32,1
2,90 / 2,89
80
437.051,–
43,4 / 41,5
4,19 / 4,24
41,6 / 42,5
2,90 / 2,89
81
486.905,–
51,8 / 49,7
3,96 / 4,12
49,0 / 51,1
2,78 / 2,76
83
562.279,–
64,5 / 62,3
3,64 / 3,78
61,5 / 63,7
2,97 / 2,94
83
CZK
CZK
CZK
CZK
15.133,–
16.810,–
24.653,–
11.198,–
15.133,–
16.810,–
24.653,–
11.198,–
15.133,–
16.810,–
24.653,–
11.198,–
15.133,–
20.500,–
24.653,–
11.198,–
17.716,–
20.500,–
30.064,–
13.656,–
17.716,–
20.500,–
30.064,–
13.656,–
17.716,–
20.500,–
30.064,–
13.656,–
CZK
3.993,–
3.993,–
3.993,–
3.993,–
7.986,–
7.986,–
7.986,–
CZK
CZK
5.932,–
14.583,–
5.932,–
14.583,–
5.932,–
14.583,–
5.932,–
14.583,–
5.932,–
29.166,–
5.932,–
29.166,–
5.932,–
29.166,–
CZK
12.210,–
12.210,–
12.210,–
12.210,–
24.420,–
24.420,–
24.420,–
CZK
10.272,–
10.272,–
10.272,–
10.272,–
10.272,–
10.272,–
10.272,–
kW
Options
OP10
OPSP
OPHP
OPZL
Evaporator electric heater
One centrifugal pump (low lift)
One centrifugal pump (high lift)
Low leaving water operation down to -10 °C
Kit
Demand PCB Remote:
On/Off, Cool/heat, thermo On/Off
EKRUAHT
Additional remote user interface
BHGP26A1 Digital pressure gauges
External adaptor for:
DTA104A62
Demand and Low noise control
Modbus interface
RTD-W
EKRP1AHT
5
→ EUWA-KBZW
▪ EUWA-KBZW
AIR COOLED CHILLER
Unit size
Price version N *
Price version P *
Price version B *
Cooling capacity version N / P / B
EER version N / P / B
Sound power level
EUWA*5KBZW
EUWA*8KBZW
EUWA*10KBZW
EUWA*12KBZW
dB(A)
94.355,–
120.626,–
146.956,–
11,2 / 11,7 / 11,7
2,46 / 2,55 / 2,55
67
135.442,–
161.685,–
187.985,–
17,7 / 18,2 / 18,2
2,38 / 2,46 / 2,46
76
155.434,–
181.678,–
208.009,–
22,3 / 22,9 / 22,9
2,51 / 2,58 / 2,58
78
187.437,–
213.708,–
240.009,–
26,6 / 26,8 / 26,8
2,24 / 2,29 / 2,29
78
7.059,–
7.059,–
695,–
7.059,–
7.059,–
1.649,–
7.059,–
7.059,–
1.649,–
7.059,–
7.059,–
1.649,–
CZK
CZK
CZK
kW
Options
OPZH
OPZL
OPHF
glycol application to -5°C LWE
glycol application to -10°C LWE
fan motor size up (50 Pa ESP)
CZK
CZK
CZK
Version *
OP10
OPHP
evaporator heater tape
pump size up
CZK
CZK
soft starter kit
gauges kit 5/8Hp units
gauges kit 10/12Hp units
BMS address card
remote user interface
remote buffertank (200 l)
CZK
CZK
CZK
CZK
CZK
CZK
N
P
B
N
P
B
N
P
B
N
P
B
4.716,– 9.491,– 11.660,– 4.716,– 9.491,– 11.660,– 4.716,– 9.491,– 11.660,– 4.716,– 9.491,– 11.660,–
–
2.893,– 2.893,–
–
2.893,– 2.893,–
–
2.893,– 2.893,–
–
2.893,– 2.893,–
Kit
EKSS
EKGAU5/8KA
EKGAU10/12KA
EKAC10C
EKRUMCA
EKBT
12.239,–
6.598,–
–
4.290,–
6.286,–
42.881,–
Unit size
Price version N *
Price version P *
Price version B *
Cooling capacity version N / P / B
EER version N / P / B
Sound power level
CZK
CZK
CZK
kW
dB(A)
12.239,–
6.598,–
–
4.290,–
6.286,–
42.881,–
12.239,–
–
6.598,–
4.290,–
6.286,–
42.881,–
12.239,–
–
6.598,–
4.290,–
6.286,–
42.881,–
EUWA*16KBZW
EUWA*20KBZW
EUWA*24KBZW
231.849,–
266.889,–
293.161,–
34,4 / 35,4 / 35,4
2,31 / 2,34 / 2,34
79
292.901,–
327.940,–
354.213,–
46,4 / 47,5 / 47,5
2,56 / 2,61 / 2,61
81
332.021,–
367.031,–
393.331,–
55,0 / 56,1 / 56,1
2,28 / 2,32 / 2,32
81
7.059,–
7.059,–
3.211,–
P
9.491,–
11.025,–
7.059,–
7.059,–
3.211,–
P
9.491,–
11.025,–
7.059,–
7.059,–
3.211,–
P
9.491,–
11.025,–
Options
OPZH
OPZL
OPHF
Version *
OP10
OPHP
glycol application to -5°C LWE
glycol application to -10°C LWE
fan motor size up (50 Pa ESP)
CZK
CZK
CZK
evaporator heater tape
pump size up
CZK
CZK
gauges kit 16Hp units
gauges kit 20/24Hp units
BMS address card
remote user interface
remote buffertank (200 l)
CZK
CZK
CZK
CZK
CZK
N
4.716,–
–
B
11.660,–
11.025,–
N
4.716,–
–
B
11.660,–
11.025,–
N
4.716,–
–
Kit
EKGAU16KA
EKGAU20/24KA
EKAC10C
EKRUMCA
EKBT
10.735,–
–
4.290,–
6.286,–
42.881,–
–
10.735,–
4.290,–
6.286,–
42.881,–
Note: EKAC10C is needed for direct BMS connection via Modbus
EKAC10C is needed to install EKRUMCA
Remarks
* N = Normal unit with mainswitch, flowswitch, without hydraulic module.
P = N-version with hydraulic module with pump & expansion vessel.
B = N-version with hydraulic module with buffertank, pump & expansion vessel.
6
–
10.735,–
4.290,–
6.286,–
42.881,–
B
11.660,–
11.025,–
→ EUWY-KBZW
▪ EUWY-KBZW
AIR COOLED HEAT PUMP
Unit size
Price version N *
Price version P *
Price version B *
Cooling capacity version N / P / B
EER version N / P / B
Heating capacity version N / P / B
COP version N / P / B
Sound power level
CZK
CZK
CZK
kW
kW
dB(A)
EUWY*5KBZW
EUWY*8KBZW
EUWY*10KBZW
EUWY*12KBZW
108.532,–
134.804,–
161.077,–
9,05 / 9,42 / 9,42
2,37 / 2,41 / 2,41
12,0 / 11,4 / 11,4
2,60 / 2,52 / 2,52
67
155.724,–
181.996,–
208.326,–
17,0 / 17,5 / 17,5
2,26 / 2,34 / 2,34
18,6 / 17,9 / 17,9
2,61 / 2,60 / 2,60
76
178.727,–
205.028,–
231.328,–
20,8 / 21,5 / 21,5
2,4 / 2,47 / 2,47
24,2 / 23,3 / 23,3
2,65 / 2,59 / 2,59
78
215.589,–
241.860,–
268.163,–
24,8 / 25,4 / 25,4
2,16 / 2,21 / 2,21
27,2 / 26,0 / 26,0
2,50 / 2,50 / 2,50
78
Options
OPZH
OPZL
OPHF
Version *
OP10
OPHP
glycol application to -5°C LWE
glycol application to -10°C LWE
fan motor size up (50 Pa ESP)
CZK
CZK
CZK
evaporator heater tape
pump size up
CZK
CZK
soft starter kit
gauges kit 5/8Hp units
gauges kit 10/12Hp units
BMS address card
remote user interface
remote buffertank (200 l)
CZK
CZK
CZK
CZK
CZK
CZK
7.059,–
7.059,–
7.059,–
7.059,–
7.059,–
7.059,–
7.059,–
7.059,–
695,–
1.649,–
1.649,–
1.649,–
N
P
B
N
P
B
N
P
B
N
P
B
4.716,– 9.491,– 11.660,– 4.716,– 9.491,– 11.660,– 4.716,– 9.491,– 11.660,– 4.716,– 9.491,– 11.660,–
–
2.893,– 2.893,–
–
2.893,– 2.893,–
–
2.893,– 2.893,–
–
2.893,– 2.893,–
Kit
EKSS
EKGAU5/8KA
EKGAU10/12KA
EKAC10C
EKRUMCA
EKBT
12.239,–
6.598,–
–
4.290,–
6.286,–
42.881,–
Unit size
Price version N *
Price version P *
Price version B *
Cooling capacity version N / P / B
EER version N / P / B
Heating capacity version N / P / B
COP version N / P / B
Sound power level
CZK
CZK
CZK
kW
kW
dB(A)
12.239,–
6.598,–
–
4.290,–
6.286,–
42.881,–
12.239,–
–
6.598,–
4.290,–
6.286,–
42.881,–
12.239,–
–
6.598,–
4.290,–
6.286,–
42.881,–
EUWY*16KBZW
EUWY*20KBZW
EUWY*24KBZW
266.600,–
301.639,–
327.940,–
34,1 / 35,0 / 35,0
2,29 / 2,3 / 2,3
37,1 / 35,7 / 35,7
2,61 / 2,55 / 2,55
79
336.824,–
371.863,–
398.164,–
39,8 / 40,9 / 40,9
2,43 / 2,46 / 2,46
46,2 / 44,5 / 44,5
2,64 / 2,6 / 2,6
81
381.845,–
416.885,–
443.127,–
49,8 / 50,9 / 50,9
2,18 / 2,22 / 2,22
54,2 / 52,5 / 52,5
2,51 / 2,49 / 2,49
81
7.059,–
7.059,–
3.211,–
P
9.491,–
11.025,–
7.059,–
7.059,–
3.211,–
P
9.491,–
11.025,–
7.059,–
7.059,–
3.211,–
P
9.491,–
11.025,–
Options
OPZH
OPZL
OPHF
Version *
OP10
OPHP
glycol application to -5°C LWE
glycol application to -10°C LWE
fan motor size up (50 Pa ESP)
CZK
CZK
CZK
evaporator heater tape
pump size up
CZK
CZK
gauges kit 16Hp units
gauges kit 20/24Hp units
BMS address card
remote user interface
remote buffertank (200 l)
CZK
CZK
CZK
CZK
CZK
N
4.716,–
–
B
11.660,–
11.025,–
N
4.716,–
–
B
11.660,–
11.025,–
N
4.716,–
–
Kit
EKGAU16KA
EKGAU20/24KA
EKAC10C
EKRUMCA
EKBT
10.735,–
–
4.290,–
6.286,–
42.881,–
–
10.735,–
4.290,–
6.286,–
42.881,–
Note: EKAC10C is needed for direct BMS connection via Modbus
EKAC10C is needed to install EKRUMCA
Remarks
* N = Normal unit with mainswitch, flowswitch, without hydraulic module.
P = N-version with hydraulic module with pump & expansion vessel.
B = N-version with hydraulic module with buffertank, pump & expansion vessel.
7
–
10.735,–
4.290,–
6.286,–
42.881,–
B
11.660,–
11.025,–
→ EWAQ-DAYN
▪ EWAQ-DAYN
AIR COOLED CHILLER
Unit size
EWAQ080DAYN
EWAQ100DAYN
EWAQ130DAYN
EWAQ150DAYN
dB(A)
490.889,–
79,4 / 81,0
2,94 / 2,93
3,88 / 3,82
86
611.578,–
104 / 106
2,82 / 2,85
3,79 / 3,83
86
763.768,–
130 / 133
2,74 / 2,77
4,03 / 3,97
88
824.274,–
151 / 154
2,64 / 2,66
3,95 / 3,96
89
single pump contactor
twin pump contactor
single pump
twin pump
high ESP - single pump
buffer tank
inverter fans (for low ambient -15°C)
glycol 0°C / -10°C
dual pressure relief valve
evaporator heater tape
service valves
A-meter / V-meter
low noise (=OPIF + compressor housing)
condenser protection grills
CZK
CZK
CZK
CZK
CZK
CZK
CZK
CZK
CZK
CZK
CZK
CZK
CZK
CZK
8.190,–
17.909,–
66.701,–
100.051,–
100.051,–
48.558,–
33.967,–
6.987,–
23.457,–
11.538,–
23.574,–
16.411,–
50.935,–
6.370,–
8.190,–
17.909,–
66.701,–
100.051,–
100.051,–
48.558,–
33.967,–
6.987,–
23.457,–
11.538,–
23.574,–
16.411,–
50.935,–
6.370,–
8.190,–
17.909,–
66.701,–
100.051,–
100.051,–
48.558,–
33.967,–
6.987,–
33.321,–
11.538,–
23.574,–
16.411,–
50.935,–
10.010,–
8.190,–
17.909,–
66.701,–
100.051,–
100.051,–
48.558,–
33.967,–
6.987,–
33.321,–
11.538,–
23.574,–
16.411,–
50.935,–
10.010,–
adress card
remote user interface
counter pipes
CZK
CZK
CZK
8.734,–
12.738,–
1.822,–
8.734,–
12.738,–
1.822,–
8.734,–
12.738,–
1.822,–
8.734,–
12.738,–
1.822,–
EWAQ180DAYN
EWAQ210DAYN
EWAQ240DAYN
EWAQ260DAYN
dB(A)
974.557,–
181 / 184
2,76 / 2,77
4,04 / 4,02
90
1.046.394,–
208 / 211
2,74 / 2,75
4,00 / 4,02
90
1.181.264,–
234 / 238
2,77 / 2,82
3,89 / 4,00
91
1.296.581,–
252 / 256
2,63 / 2,67
3,73 / 3,84
91
single pump contactor
twin pump contactor
single pump
twin pump
high ESP - single pump
buffer tank
inverter fans (for low ambient -15°C)
glycol 0°C / -10°C
dual pressure relief valve
evaporator heater tape
service valves
A-meter / V-meter
low noise (=OPIF + compressor housing)
condenser protection grills
CZK
CZK
CZK
CZK
CZK
CZK
CZK
CZK
CZK
CZK
CZK
CZK
CZK
CZK
8.190,–
17.909,–
90.951,–
136.454,–
136.454,–
48.558,–
50.935,–
6.987,–
33.321,–
11.538,–
23.574,–
16.411,–
76.447,–
10.010,–
8.190,–
17.909,–
90.951,–
136.454,–
136.454,–
48.558,–
50.935,–
6.987,–
33.321,–
11.538,–
23.574,–
16.411,–
76.447,–
10.010,–
8.190,–
17.909,–
97.027,–
145.555,–
145.555,–
48.558,–
82.495,–
6.987,–
33.321,–
11.538,–
23.574,–
16.411,–
123.742,–
12.419,–
8.190,–
17.909,–
97.027,–
145.555,–
145.555,–
48.558,–
82.495,–
6.987,–
33.321,–
11.538,–
23.574,–
16.411,–
123.742,–
12.419,–
adress card
remote user interface
counter pipes
counter pipes
CZK
CZK
CZK
CZK
8.734,–
12.738,–
1.822,–
–
8.734,–
12.738,–
1.822,–
–
8.734,–
12.738,–
–
2.257,–
8.734,–
12.738,–
–
2.257,–
Price
Cooling capacity version N / P or B
EER version N / P or B
ESEER version N / P or B
Sound power level
CZK
kW
Options
OPSC
OPTC
OPSP
OPTP
OPHP
OPBT
OPIF
OPZL
OP03
OP10
OP12
OP57
OPLN
OPCG
Kit
EKACPG
EKRUPG
EKGN 210
Unit size
Price
Cooling capacity version N / P or B
EER version N / P or B
ESEER version N / P or B
Sound power level
CZK
kW
Options
OPSC
OPTC
OPSP
OPTP
OPHP
OPBT
OPIF
OPZL
OP03
OP10
OP12
OP57
OPLN
OPCG
Kit
EKACPG
EKRUPG
EKGN 210
EKGN 260
Note: EKACPG needs to be installed together with EKLONPG and EKBNPG
8
→ EWYQ-DAYN
▪ EWYQ-DAYN
AIR COOLED HEAT PUMP
Unit size
EWYQ080DAYN
EWYQ100DAYN
EWYQ130DAYN
EWYQ150DAYN
dB(A)
575.645,–
76,6 / 78,1
2,86 / 2,84
3,84 / 3,76
88,2 / 86,5
2,89 / 2,79
86
684.973,–
100 / 101
2,72 / 2,72
3,68 / 3,68
115 / 113
2,97 / 2,89
86
922.887,–
135 / 138
2,79 / 2,82
4,03 / 3,99
150 / 148
2,97 / 2,90
88
975.496,–
144 / 147
2,55 / 2,57
3,84 / 3,84
166 / 163
2,79 / 2,71
89
single pump contactor
twin pump contactor
single pump
twin pump
high ESP - single pump
buffer tank
inverter fans (for low ambient -15°C)
glycol 0°C / -10°C
dual pressure relief valve
evaporator heater tape
service valves
A-meter / V-meter
low noise (=OPIF + compressor housing)
condenser protection grills
CZK
CZK
CZK
CZK
CZK
CZK
CZK
CZK
CZK
CZK
CZK
CZK
CZK
CZK
8.190,–
17.909,–
66.701,–
100.051,–
100.051,–
48.558,–
33.967,–
6.987,–
23.457,–
11.538,–
23.574,–
16.411,–
50.935,–
6.370,–
8.190,–
17.909,–
66.701,–
100.051,–
100.051,–
48.558,–
33.967,–
6.987,–
23.457,–
11.538,–
23.574,–
16.411,–
50.935,–
6.370,–
8.190,–
17.909,–
66.701,–
100.051,–
100.051,–
48.558,–
33.967,–
6.987,–
33.321,–
11.538,–
23.574,–
16.411,–
50.935,–
10.010,–
8.190,–
17.909,–
66.701,–
100.051,–
100.051,–
48.558,–
33.967,–
6.987,–
33.321,–
11.538,–
23.574,–
16.411,–
50.935,–
10.010,–
adress card
remote user interface
counter pipes
CZK
CZK
CZK
8.734,–
12.738,–
1.822,–
8.734,–
12.738,–
1.822,–
8.734,–
12.738,–
1.822,–
8.734,–
12.738,–
1.822,–
EWYQ180DAYN
EWYQ210DAYN
EWYQ230DAYN
EWYQ250DAYN
dB(A)
1.108.133,–
182 / 185
2,81 / 2,82
4,06 / 4,02
200 / 197
2,89 / 2,82
90
1.239.860,–
210 / 213
2,75 / 2,76
3,94 / 3,96
227 / 223
2,89 / 2,82
90
1.314.510,–
229 / 233
2,74 / 2,78
3,93 / 4,04
260 / 256
3,03 / 2,98
91
1.430.362,–
251 / 254
2,64 / 2,67
3,76 / 3,87
283 / 279
2,87 / 2,83
91
single pump contactor
twin pump contactor
single pump
twin pump
high ESP - single pump
buffer tank
inverter fans (for low ambient -15°C)
glycol 0°C / -10°C
dual pressure relief valve
evaporator heater tape
service valves
A-meter / V-meter
low noise (=OPIF + compressor housing)
condenser protection grills
CZK
CZK
CZK
CZK
CZK
CZK
CZK
CZK
CZK
CZK
CZK
CZK
CZK
CZK
8.190,–
17.909,–
90.951,–
136.454,–
136.454,–
48.558,–
50.935,–
6.987,–
33.321,–
11.538,–
23.574,–
16.411,–
76.447,–
10.010,–
8.190,–
17.909,–
90.951,–
136.454,–
136.454,–
48.558,–
50.935,–
6.987,–
33.321,–
11.538,–
23.574,–
16.411,–
76.447,–
10.010,–
8.190,–
17.909,–
97.027,–
145.555,–
145.555,–
48.558,–
82.495,–
6.987,–
33.321,–
11.538,–
23.574,–
16.411,–
123.742,–
12.419,–
8.190,–
17.909,–
97.027,–
145.555,–
145.555,–
48.558,–
82.495,–
6.987,–
33.321,–
11.538,–
23.574,–
16.411,–
123.742,–
12.419,–
adress card
remote user interface
counter pipes
counter pipes
CZK
CZK
CZK
CZK
8.734,–
12.738,–
1.822,–
–
8.734,–
12.738,–
1.822,–
–
8.734,–
12.738,–
–
2.257,–
8.734,–
12.738,–
–
2.257,–
Price
Cooling capacity version N / P or B
EER version N / P or B
ESEER version N / P or B
Heating capacity version N / P or B
COP version N / P or B
Sound power level
CZK
kW
kW
Options
OPSC
OPTC
OPSP
OPTP
OPHP
OPBT
OPIF
OPZL
OP03
OP10
OP12
OP57
OPLN
OPCG
Kit
EKACPG
EKRUPG
EKGN 210
Unit size
Price
Cooling capacity version N / P or B
EER version N / P or B
ESEER version N / P or B
Heating capacity version N / P or B
COP version N / P or B
Sound power level
CZK
kW
kW
Options
OPSC
OPTC
OPSP
OPTP
OPHP
OPBT
OPIF
OPZL
OP03
OP10
OP12
OP57
OPLN
OPCG
Kit
EKACPG
EKRUPG
EKGN 210
EKGN 260
Note: EKACPG needs to be installed together with EKLONPG and EKBNPG
OPIF needs for heating down to -15°C ambient temperature, without OPIF down to -10°C ambient temperature.
9
→ EWWP-KBW1N
▪ EWWP-KBW1N
WATER COOLED CHILLER
Unit size
EWWP014KBW1N
EWWP022KBW1N
EWWP028KBW1N
EWWP035KBW1N
135.817,–
21,4
3,49
27,5
64
155.869,–
27,8
3,54
35,6
64
188.014,–
kW
dB(A)
94.673,–
12,9
3,44
16,7
64
glycol application to -5 °C LWE
glycol application to -10 °C LWE
CZK
CZK
7.059,–
7.059,–
7.059,–
7.059,–
7.059,–
7.059,–
7.059,–
7.059,–
low noise kit 5 HP
low noise kit 8/10/12 HP
BMS address card
remote user interface
hydraulic module
hydraulic module – pump size up
hydraulic module
hydraulic module – pump size up
CZK
CZK
CZK
CZK
CZK
CZK
CZK
CZK
6.134,–
–
4.290,–
6.286,–
67.099,–
68.921,–
–
–
–
6.134,–
4.290,–
6.286,–
67.099,–
68.921,–
–
–
–
6.134,–
4.290,–
6.286,–
67.099,–
68.921,–
71.351,–
73.233,–
–
6.134,–
4.290,–
6.286,–
–
–
71.351,–
73.233,–
Price
Cooling capacity
EER
Heat rejection capacity
Sound power level
CZK
kW
32,3
3,54
41,5
71
Options
OPZH
OPZL
Kit
EKLS1
EKLS2
EKAC10C
EKRUMCA
EHMC10A10
EHMC10A80
EHMC15A10
EHMC15A80
Unit size
Price
Cooling capacity
EER
Heat rejection capacity
Sound power level
EWWP045KBW1N
EWWP055KBW1N
EWWP065KBW1N
kW
dB(A)
232.486,–
42,8
3,51
55,0
67
293.711,–
55,7
3,48
71,7
67
332.976,–
64,7
3,55
83
74
CZK
kW
Options
OPZH
OPZL
glycol application to -5 °C LWE
glycol application to -10 °C LWE
CZK
CZK
7.059,–
7.059,–
7.059,–
7.059,–
7.059,–
7.059,–
Kit
EKLS2
EKAC10C
EKRUMCA
EHMC15A10
EHMC15A80
EHMC30A10
EHMC30A80
low noise kit 8/10/12 HP (2 pcs.)
BMS address card
remote user interface
hydraulic module
hydraulic module – pump size up
hydraulic module
hydraulic module – pump size up
CZK
CZK
CZK
CZK
CZK
CZK
CZK
12.268,–
4.290,–
6.286,–
71.351,–
73.233,–
75.980,–
78.412,–
12.268,–
4.290,–
6.286,–
–
–
75.980,–
78.412,–
12.268,–
4.290,–
6.286,–
–
–
75.980,–
78.412,–
Note: EKAC10C is needed for direct BMS connection via Modbus
EKAC10C is needed to install EKRUMCA
10
→ EWWP-KAW1M
▪ EWWP-KAW1M
WATER COOLED CHILLER
Capacity index
090
100
110
120
CZK
kW
dB(A)
EWWP045KAW1M
EWWP045KAW1M
ECB2MUW
420.508,–
85,7
71
EWWP045KAW1M
EWWP055KAW1M
ECB2MUW
472.614,–
98,6
71
EWWP055KAW1M
EWWP055KAW1M
ECB2MUW
524.720,–
112
71
EWWP055KAW1M
EWWP065KAW1M
ECB2MUW
583.435,–
121
75
CZK
CZK
14.118,–
14.118,–
14.118,–
14.118,–
14.118,–
14.118,–
14.118,–
14.118,–
Basic model
Control box
Price
Cooling capacity
Sound power level
Options
OPZH
OPZL
glycol application to -5°C LWE
glycol application to -10°C LWE
Capacity index
Basic model
Control box
Price
Cooling capacity
Sound power level
130
145
155
165
EWWP065KAW1M
EWWP065KAW1M
EWWP045KAW1M
EWWP055KAW1M
EWWP055KAW1M
ECB3MUW
696.541,–
154
73
EWWP055KAW1M
EWWP055KAW1M
EWWP055KAW1M
ECB3MUW
748.647,–
167
73
21.177,–
21.177,–
21.177,–
21.177,–
CZK
kW
dB(A)
ECB2MUW
642.123,–
130
77
EWWP045KAW1M
EWWP045KAW1M
EWWP055KAW1M
ECB3MUW
644.408,–
141
73
CZK
CZK
14.118,–
14.118,–
21.177,–
21.177,–
175
185
195
CZK
kW
dB(A)
EWWP055KAW1M
EWWP055KAW1M
EWWP065KAW1M
ECB3MUW
807.335,–
176
76
EWWP055KAW1M
EWWP065KAW1M
EWWP065KAW1M
ECB3MUW
866.050,–
185
78
EWWP065KAW1M
EWWP065KAW1M
EWWP065KAW1M
ECB3MUW
924.738,–
194
79
CZK
CZK
21.177,–
21.177,–
21.177,–
21.177,–
21.177,–
21.177,–
Options
OPZH
OPZL
glycol application to -5°C LWE
glycol application to -10°C LWE
Capacity index
Basic model
Control box
Price
Cooling capacity
Sound power level
Options
OPZH
OPZL
glycol application to -5°C LWE
glycol application to -10°C LWE
11
→ EWLP-KBW1N
▪ EWLP-KBW1N
CONDENSERLESS CHILLER
Unit size
EWLP012KBW1N
EWLP020KBW1N
EWLP026KBW1N
EWLP030KBW1N
dB(A)
85.210,–
12,1
2,88
64
122.246,–
20
3,03
64
140.272,–
26,8
3,15
64
169.207,–
31,2
3,09
71
glycol application to -5°C LWE
glycol application to -10°C LWE
CZK
CZK
7.059,–
7.059,–
7.059,–
7.059,–
7.059,–
7.059,–
7.059,–
7.059,–
low noise kit 5 HP
low noise kit 8/10/12 HP
BMS address card
remote user interface
hydraulic module
hydraulic module – pump size up
hydraulic module
hydraulic module – pump size up
CZK
CZK
CZK
CZK
CZK
CZK
CZK
CZK
6.134,–
–
4.290,–
6.286,–
67.099,–
68.921,–
–
–
–
6.134,–
4.290,–
6.286,–
67.099,–
68.921,–
–
–
–
6.134,–
4.290,–
6.286,–
67.099,–
68.921,–
71.351,–
73.233,–
–
6.134,–
4.290,–
6.286,–
–
–
71.351,–
73.233,–
Price
Cooling capacity
EER
Sound power level
CZK
kW
Options
OPZH
OPZL
Kit
EKLS1
EKLS2
EKAC10C
EKRUMCA
EHMC10A10
EHMC10A80
EHMC15A10
EHMC15A80
Unit size
EWLP040KBW1N
EWLP055KBW1N
EWLP065KBW1N
dB(A)
209.222,–
40
2,99
67
264.343,–
53,7
3,02
67
299.672,–
62,4
3,07
74
glycol application to -5°C LWE
glycol application to -10°C LWE
CZK
CZK
7.059,–
7.059,–
7.059,–
7.059,–
7.059,–
7.059,–
low noise kit 8/10/12 HP (2 pcs.)
BMS address card
remote user interface
hydraulic module
hydraulic module – pump size up
hydraulic module
hydraulic module – pump size up
CZK
CZK
CZK
CZK
CZK
CZK
CZK
12.268,–
4.290,–
6.286,–
71.351,–
73.233,–
75.980,–
78.412,–
12.268,–
4.290,–
6.286,–
–
–
75.980,–
78.412,–
12.268,–
4.290,–
6.286,–
–
–
75.980,–
78.412,–
Price
Cooling capacity
EER
Sound power level
CZK
kW
Options
OPZH
OPZL
Kit
EKLS2
EKAC10C
EKRUMCA
EHMC15A10
EHMC15A80
EHMC30A10
EHMC30A80
Note: EKAC10C is needed for direct BMS connection via Modbus
EKAC10C is needed to install EKRUMCA
12
→ ERQ
▪ ERQ Inverter heat pump condensing units
ERQ-A
High efficiency inverter heat pump outdoor units for connection to DX heat exchangers in Air
Handling Units (AHU) or to CYQ Air Curtains
Type for 1~ 230V power supply
Capacity index
Nominal cooling capacity
Nominal heating capacity
Price
ERQ100AV1
ERQ125AV1
ERQ140AV1
100
11,2
12,5
95.665,–
125
14,0
16,0
119.544,–
140
15,5
18,0
133.924,–
ERQ125AW1
ERQ200AW1
ERQ250AW1
125
14,0
16,0
104.167,–
200
22,4
25,0
166.124,–
250
28,0
31,5
193.711,–
kW
kW
CZK
Type for 3N~ 400V power supply
Capacity index
Nominal cooling capacity
Nominal heating capacity
Price
kW
kW
CZK
Notes:
- When using for connection to CYQ Air Curtains, select an ERQ outdoor unit with an equal or higher capacity index than the capacity index of the Air Curtain
- Specified capacity values are for evaporation temperature = 6 °C (cooling) / condensing temperature = 46 °C (heating), evaporator superheat = 5K,condenser sub-cool = 3K,
on-coil temperature = 27 °CDB / 19 °CWB (cooling) / = 20 °CDB (heating)
Control box
Control type
Control options
Price
CZK
EKEQDCB
EKEQFCB
Daikin control
• Room temperature control [via Remote Controller
(accessory) or via External room temperature sensor
(accessory)]
• Return air temperature control (via a supplied thermistor)
19.588,–
Free (External) control
• 0~10V direct capacity control
(5V = maintain capacity, >5V colder air wanted, <5V
warmer air wanted)
• Fixed evaporation / condensation temperature control
19.838,–
Notes:
- A control box is a necessary component of the system for AHU applications; it is not necessary for connection to CYQ Air Curtains
- A wired remote controller (Standard or Basic) is required for the EKEQDCB control box; for the EKEQFCB box, it is optional (required for commissioning and servicing only)
- Switching between cooling/heating operation with the EKEQFCB box must be done from the external control system, or via the optional KRC19-26 Cool/Heat selector
Allowed heat exchanger capacity [kW]
Expansion valve kit
Minimum
6,3
7,9
10,0
12,4
15,5
17,7
24,7
EKEXV63
EKEXV80
EKEXV100
EKEXV125
EKEXV140
EKEXV200
EKEXV250
Maximum
7,8
9,9
12,3
15,4
17,6
24,6
30,8
Combinable units
ERQ100y
y
y
y
ERQ125y
y
y
y
y
ERQ140y
y
y
y
ERQ200-
ERQ250-
y
y
y
y
y
y
y
y
y
Price CZK
4.601,–
4.889,–
5.064,–
5.353,–
5.526,–
6.018,–
6.394,–
Notes:
- An expansion valve kit is a necessary component of the system for AHU applications; it is not necessary for connection to CYQ Air Curtains,
- The expansion valve kit needs to be selected based on the nominal design of the AHU heat exchanger,
- The AHU heat exchanger needs to be designed for 40bar pressures, with an internal (refrigerant) volume between 0,3 and 8,3 l (not counting headers and distributors)
- Specified capacity values are for evaporation temperature = 6 °C (cooling) / condensing temperature = 46 °C (heating), evaporator superheat = 5K,condenser sub-cool = 3K,
on-coil temperature = 27 °CDB / 19 °CWB (cooling) / = 20 °CDB (heating)
Unit-specific Accessories
BRC1D52
BRC1E52B
KRP4A51
RTD-20
KRCS01-1
KRC19-26
KJB111A
Basic wired remote controller with weekly timer
Standard wired remote controller with full-text interface and back-light
Adaptor for external monitoring/control
Adaptor for external monitoring/control with 0-10VDC linear capacity control
External room temperature sensor
Mechanical cool/heat selector
Fixing box for cool/heat selector
EKEQDCB
EKEQFCB
Price CZK
y
y
y
y
y
y
y
y
y
3.096,–
4.071,–
4.977,–
11.758,–
2.371,–
1.620,–
752,–
y
y
Notes:
- A wired remote controller (Standard or Basic) is required for the EKEQDCB control box; for the EKEQFCB box, it is optional (required for commissioning and servicing only)
- Switching between cooling/heating operation with the EKEQFCB box must be done from the external control system, or via the optional KRC19-26 Cool/Heat selector
13
→ HYDRONIC KIT, ROOFTOP
▪ HYDRONIC KIT
Buffer tanks
EKBT
EKBT500N
EKBTC10N
EKBT500C
EKBTC10C
200 l buffer tank with casing
500 l buffer tank
1000 l buffer tank
500 l buffer tank with casing
1000 l buffer tank with casing
CZK
CZK
CZK
CZK
CZK
42.881,–
53.905,–
74.738,–
117.126,–
156.158,–
CZK
CZK
CZK
CZK
CZK
CZK
67.099,–
68.921,–
71.351,–
73.233,–
75.980,–
78.412,–
Hydraulic modules
EHMC10A10
EHMC10A80
EHMC15A10
EHMC15A80
EHMC30A10
EHMC30A80
hydraulic module
hydraulic module – high ESP
hydraulic module
hydraulic module – high ESP
hydraulic module
hydraulic module – high ESP
▪ UATYQ-CY1
ROOFTOP HEAT PUMP
Convertible return and supply air: fan can be mounted in two directions
Unit size
Price
Cooling capacity
EER
Heating capacity
COP
Sound power level
UATYQ250CY1
UATYQ350CY1
UATYQ450CY1
UATYQ550CY1
UATYQ600CY1
UATYQ700CY1
dB(A)
175.852,–
27,34
3,36
24,91
3,40
82
255.232,–
35,58
3,30
34,79
3,21
83
330.031,–
44,72
3,43
41,79
3,25
83
392.687,–
55,69
3,33
53,93
3,47
87
407.246,–
66,82
3,4
61,69
3,32
90
408.731,–
72,6
3,36
69,61
3,25
90
CZK
CZK
CZK
CZK
CZK
CZK
CZK
CZK
CZK
26.881,–
29.657,–
16.926,–
41.285,–
–
–
–
–
–
26.881,–
29.657,–
16.926,–
–
43.381,–
–
–
–
–
26.881,–
29.657,–
16.926,–
–
–
45.551,–
–
–
–
26.881,–
29.657,–
16.926,–
–
–
–
47.793,–
–
–
26.881,–
29.657,–
16.926,–
–
–
–
–
50.178,–
–
26.881,–
29.657,–
16.926,–
–
–
–
–
–
52.709,–
CZK
kW
kW
Options
DEC101A51
DEC102A51
DTA103A51
ECONO250AY1
ECONO350AY1
ECONO450AY1
ECONO550AY1
ECONO600AY1
ECONO700AY1
▪ UATYP-AY1
ROOFTOP HEAT PUMP
Belt driven fan enables air volume and static pressure to be adjusted as required.
Unit size
Price
Cooling capacity
EER
Heating capacity
COP
Sound pressure level at 1m
CZK
kW
kW
dB(A)
UATYP850AY1B
UATYPC10AY1
UATYPC12AY1
482.354,–
78,60
2,18
87,80
2,73
74
599.135,–
101,10
2,34
102,30
2,45
80
686.874,–
109,60
2,27
126,30
2,7
80
14
→ FWE-C, Low ESP duct fan coil
▪ FWE-C
FAN COIL, ACCESSORIES
4-speed fan motor, available static pressure up to 50Pa
Low ESP duct unit FWE-C
FWE**CT-, 2 pipe unit,
standard, without valves
"FWE**CTV, 2 pipe unit,
with 3-ways 230V on/off valve, factory mounted
FWE**CTT, 2 pipe unit,
with 2-ways 230V on/off valve, factory mounted
Cooling capacity (Total at Super High Speed)
Heating capacity (2-pipe at Super High Speed)
FWE**CF-, 4 pipe unit,
standard, without valves
FWE**CFV, 4 pipe unit,
with 3-ways 230V on/off valves, factory mounted
FWE**CFT, 4 pipe unit,
with 2-ways 230V on/off valves, factory mounted
Cooling capacity (Total at Super High Speed)
Heating capacity (4-pipe at Super High Speed) (1)
02
03
04
06
07
08
10
CZK
6.245,–
7.081,–
7.661,–
9.979,–
10.750,–
12.618,–
15.192,–
CZK
10.698,–
11.530,–
12.170,–
14.477,–
15.245,–
17.038,–
19.601,–
CZK
8.775,–
9.608,–
10.184,–
12.554,–
13.259,–
15.117,–
17.679,–
kW
kW
2,17
2,79
3,22
4,28
4,34
5,61
6,06
7,66
6,83
9,26
7,84
10,50
9,96
13,00
CZK
7.274,–
8.240,–
8.948,–
11.523,–
12.296,–
14.421,–
16.995,–
CZK
15.181,–
16.142,–
16.847,–
19.409,–
20.177,–
22.291,–
24.854,–
CZK
12.298,–
13.259,–
13.964,–
16.526,–
17.295,–
19.409,–
21.971,–
kW
kW
2,10
2,30
3,16
3,53
3,98
4,56
6,05
6,17
6,76
7,60
7,79
8,52
9,91
10,40
02
03
04
06
07
08
10
07
08
10
Accessories for FWE-C
2 pipes 3-ways on/off 230V valve kit
EK2MV3B10C5
2.539,–
EK2MV2B10C5
2.132,–
EK4MV3B10C5
4.816,–
EK4MV2B10C5
4.179,–
CZK
2 pipes 2-ways on/off 230V valve kit
CZK
4 pipes 3-ways on/off 230V valve kit
CZK
4 pipes 2-ways on/off 230V valve kit
CZK
Controller for FWE-C
02
Controller electronic
Standard version, (see note 2)
CZK
Controller electronic
Advanced version
CZK
Controller electronic
Advanced Plus version
CZK
Wall mounting kit (spacing collar)
for FWEC*A
CZK
Temperature sensor kit
for FWEC*A
CZK
Relative humidity sensor kit
for FWEC2A and FWEC3A
CZK
03
04
06
FWEC1A
2.546,–
FWEC2A
3.993,–
FWEC3A
5.439,–
FWFCKA
435,–
FWTSKA
231,–
FWHSKA
607,–
EPIMSB6
3.473,–
Master / Slave interface
CZK
Notes:
(1) Rating conditions: air 20°C DB, entering water 50°C, leaving water 40°C
(2) FWEC1A can operate with 3 speeds of fan only, if it also manages 2 valves on 4-pipes unit
15
→ FWB-B, Medium ESP duct fan coil
▪ FWB-B
FAN COIL, ACCESSORIES
Low sound power levels and electrical absorption thanks to plastic impeller and improved electric motor.
Medium ESP duct unit FWB-B
FWB**BTN, 2 pipe unit,
standard, without valves
FWB**BTV, 2 pipe unit,
with 3-ways 230V on/off valve, factory mounted
FWB**BTNE, 2 pipe unit, without valves and
electric heater, factory mounted
FWB**BTVE, 2 pipe unit, with 3-ways 230V on/off
valve and electric heater, factory mounted
Cooling capacity (Total at High Speed)
Heating capacity (2-pipe at High Speed)
Heating capacity (4-pipe at High Speed)
02
03
04
05
06
07
08
09
10
CZK
12.280,–
13.127,–
13.917,–
16.796,–
17.389,–
19.055,–
22.978,–
24.305,–
25.857,–
CZK
16.288,–
17.079,–
17.869,–
20.749,–
21.340,–
22.978,–
27.185,–
28.426,–
30.064,–
CZK
19.816,–
20.692,–
21.482,–
25.209,–
25.800,–
27.382,–
31.898,–
33.226,–
34.806,–
CZK
23.768,–
24.615,–
25.406,–
29.160,–
29.753,–
31.306,–
36.104,–
37.347,–
39.012,–
kW
kW
kW
2,61
5,47
3,14
3,14
6,01
3,14
3,49
6,47
3,14
5,08
10,31
5,99
5,45
11,39
5,99
6,47
12,28
5,99
7,57
15,05
12,80
8,67
16,85
12,80
10,34
18,78
12,80
03
04
05
06
07
08
09
10
Accessories for FWB-B
Additional single row
heat exchanger
02
EAH04A6
4.774,–
CZK
EAH07A6
5.353,–
3-way valve add. h/e
E2MV307A6
5.093,–
E2MV207A6
2.632,–
CZK
2-way valve add. h/e
CZK
Fan stop thermostat
YFSTA6
492,–
CZK
Controller for FWB-B
02
Controller electronic
Standard version
CZK
Controller electronic
Advanced version
CZK
Controller electronic
Advanced Plus version
CZK
Wall mounting kit (spacing collar)
for FWEC*A
CZK
Temperature sensor kit
for FWEC*A
CZK
Relative humidity sensor kit
for FWEC2A and FWEC3A
CZK
EAH10A6
7.059,–
E2MV310A6
5.093,–
E2MV210A6
2.778,–
03
04
05
06
FWEC1A
2.546,–
FWEC2A
3.993,–
FWEC3A
5.439,–
FWFCKA
435,–
FWTSKA
231,–
FWHSKA
607,–
EPIMSB6
3.473,–
Master / Slave interface
CZK
16
07
08
09
10
→ FWP - A, Medium ESP duct fan coil
with DC fan motor
▪ FWP-A
FAN COIL, ACCESSORIES
Low sound level and up to 50% energy saving thanks to the BLDC motor technology
Medium ESP duct unit with DC fan motor FWP-A
FWP**ATN, 2 pipe unit,
standard, without valves
FWP**ATV, 2 pipe unit,
with 3-ways 230V on/off valve, factory mounted
FWP**ATNE, 2 pipe unit, without valves and
electric heater, factory mounted
FWP**ATVE, 2 pipe unit, with 3-ways 230V on/off
valve and electric heater, factory mounted
Cooling capacity (Total at High Speed)
Heating capacity (2-pipe at High Speed)
Heating capacity (4-pipe at High Speed)
02
03
04
05
06
07
CZK
17.103,–
17.807,–
18.512,–
21.715,–
21.971,–
23.444,–
CZK
20.882,–
21.651,–
22.355,–
25.558,–
25.814,–
27.288,–
CZK
24.405,–
25.174,–
25.878,–
29.850,–
30.106,–
31.579,–
CZK
28.248,–
29.017,–
29.658,–
33.693,–
33.949,–
35.423,–
kW
kW
kW
2,61
5,47
3,14
3,14
6,01
3,14
3,49
6,47
3,14
5,08
10,31
5,99
5,45
11,39
5,99
6,47
12,28
5,99
03
04
05
06
07
Accessories for FWP-A
Additional single row
heat exchanger
02
EAH04A6
4.774,–
CZK
EAH07A6
5.353,–
3-way valve add. h/e
E2MV307A6
5.093,–
E2MV207A6
2.632,–
CZK
2-way valve add. h/e
CZK
Controller for FWP-A
02
Controller electronic
Advanced Plus version
CZK
Wall mounting kit (spacing collar)
for FWEC*A
CZK
Temperature sensor kit
for FWEC*A
CZK
Relative humidity sensor kit
for FWEC2A and FWEC3A
CZK
03
04
05
FWEC3A
5.439,–
FWFCKA
435,–
FWTSKA
231,–
FWHSKA
607,–
17
06
07
→ FWD - A, High ESP flexi type fan coil
▪ FWD - A
FAN COIL, ACCESSORIES
Straight duct connector is mounted to discharge side
2-pipe unit FWD**AT
Price
Cooling capacity (Total at High Speed)
Heating capacity (2-pipe at High Speed)
04
06
08
10
12
16
18
CZK
kW
kW
14.764,–
3,90
4,05
19.506,–
6,20
7,71
22.781,–
7,80
9,43
25.350,–
8,82
10,79
31.503,–
11,90
14,45
40.452,–
16,40
19,81
44.461,–
18,30
21,92
04
06
08
10
12
16
18
CZK
kW
kW
17.332,–
3,90
4,49
22.639,–
6,20
6,62
26.450,–
7,80
9,21
29.358,–
8,82
9,21
36.952,–
11,90
15,86
46.803,–
16,40
21,15
51.348,–
18,30
21,15
04
06
08
10
12
16
18
EDEH04A6
7.565,–
EDEH04A6
7.565,–
ED2MV04A6
5.364,–
ED4MV04A6
10.275,–
EDEHS06A6
14.227,–
EDEHB06A6
14.227,–
4-pipe unit FWD**AF
Price
Cooling capacity (Total at High Speed)
Heating capacity (4-pipe at High Speed)
Accessories for FWD
Electric heater
low capacity
CZK
Electric heater
high capacity
CZK
2-pipe 3-way valve
CZK
4-pipe 3-way valve
CZK
Vertical drainpan
CZK
Horizontal drainpan
CZK
Fan stop thermostat
CZK
Fresh air intake
CZK
Controller for FWD
EDMFA04A6
25.774,–
04
EDEHS10A6
14.227,–
EDEHB10A6
14.227,–
ED2MV10A6
5.646,–
ED4MV10A6
10.925,–
EDDPV10A6
311,–
EDDPH10A6
452,–
YFSTA6
492,–
EDMFA06A6
EDMFA10A6
26.337,–
26.846,–
06
Controller electronic
Standard version
08
10
EDEHS12A6
14.538,–
EDEHB12A6
14.538,–
ED2MV12A6
5.138,–
2 x ED2MV12A6
11.697,–
EDMFA12A6
28.454,–
12
FWEC1A
CZK
2.546,–
FWEC2A
CZK
3.993,–
FWEC3A
CZK
5.439,–
Controller electronic
Advanced version
Controller electronic
Advanced Plus version
Wall mounting kit (spacing collar)
for FWEC*A
CZK
Temperature sensor kit
for FWEC*A
CZK
Relative humidity sensor kit
for FWEC2A and FWEC3A
CZK
EDEHS18A6
16.344,–
EDEHB18A6
16.344,–
ED2MV18A6
5.928,–
2 x ED2MV18A6
12.228,–
EDDPV18A6
481,–
EDDPH18A6
621,–
EDMFA18A6
28.849,–
16
FWEC1A
EPIB6 requested
2.546,–
FWEC2A
EPIB6 requested
3.993,–
FWEC3A
EPIB6 requested
5.439,–
FWFCKA
435,–
FWTSKA
231,–
FWHSKA
607,–
EPIMSB6
3.473,–
Master / Slave interface
CZK
Power interface
–
–
CZK
Note:
For FWD size 12, 16 or 18 EPIB6 needs to be used for each FWD unit to connect to FWEC*A controllers.
If FWD size 12, 16 or 18 are used in Master/Slave application by using EPIMSB6 still EPIB6 needs to be used for each FWD to connect to EPIMSB6.
18
EPIB6
4.137,–
18
→ FWF-C, FWF-B, FWC-B, Cassette fan coils
▪ FWF-C
FAN COIL
Infrared remote control as standard with decoration panel kit.
FWF-C cassette unit
FWF**CT, 2 pipe unit,
incl. condensate pump, without valves
Cooling capacity (Total at High Speed)
Heating capacity (2-pipe at High Speed)
02
03
04
CZK
13.466,–
15.159,–
15.357,–
kW
kW
2,49
3,52
4,10
4,69
4,54
5,28
Note: Decoration panel is mandatory, it is included with other accessories in table on page 20.
▪ FWF-B
FAN COIL
Possibility to shut 1 or 2 flaps for easy installations in corners.
FWF-B cassette unit
FWF**BT, 2 pipe unit,
incl. condensate pump, without valves
Cooling capacity (Total at Super High Speed)
Heating capacity (2-pipe at Super High Speed)
FWF**BF, 4 pipe unit,
incl. condensate pump, without valves
Cooling capacity (Total at Super High Speed)
Heating capacity (4-pipe at Super High Speed)
02
03
04
05
CZK
18.663,–
20.427,–
21.961,–
23.148,–
kW
kW
2,00
2,90
3,20
4,00
4,20
5,40
5,20
6,70
CZK
20.775,–
22.569,–
23.697,–
24.884,–
kW
kW
2,00
3,80
2,70
3,80
3,50
4,90
4,50
6,10
06
07
08
09
CZK
26.986,–
27.806,–
29.132,–
30.205,–
kW
kW
5,80
8,00
6,80
8,90
7,70
10,60
8,70
12,10
CZK
28.878,–
29.782,–
30.685,–
31.729,–
kW
kW
5,80
7,50
6,60
8,40
7,60
9,70
8,70
11,00
Note: Decoration panel is mandatory, it is included with other accessories in table on page 21.
▪ FWC-B
FAN COIL
360° air discharge ensures uniform air flow and temperature distribution.
FWC-B cassette unit
FWC**BT, 2 pipe unit,
incl. condensate pump, without valves
Cooling capacity (Total at High Speed)
Heating capacity (2-pipe at High Speed)
FWC**BF, 4 pipe unit,
incl. condensate pump, without valves
Cooling capacity (Total at High Speed)
Heating capacity (4-pipe at High Speed)
Note: Decoration panel is mandatory, it is included with other accessories in table on page 21.
19
→ FWT-C, Wall mounted fan coil
→ Accessories for FWT-C, FWF-C
▪ FWT-C
FAN COIL
Flexibility via interchangeable water connection side.
FWT-C wall mounted unit
FWT**CT, 2 pipe unit,
without valves
Cooling capacity (Total at High Speed)
Heating capacity (2-pipe at High Speed)
02
03
04
05
06
CZK
8.469,–
9.457,–
9.598,–
13.071,–
13.324,–
kW
kW
2,34
3,02
2,78
3,75
3,22
4,10
4,54
6,01
5,28
6,74
▪ FWT-C + FWF-C
ACCESSORIES
Type
Decoration panel 2-pipe
Incl. wireless controller
CZK
FWF-CT
FWT-CT
DCP600TC
4.654,–
–
Standard wired remote control
MERCA
3.669,–
SRC-COA
1.863,–
SRC-HPA
1.863,–
WRC-HPC
734,–
CZK
Simplified wired remote control
CZK
Simplified wired remote control
CZK
Wireless control
CZK
2-pipe 3-way valve
CZK
MCKCW2T3VN
3.388,–
20
–
→ Accessories for FWC-B, FWF-B
▪ FWC-B, FWF-B
ACCESSORIES
Options
Decoration Panel Round Flow Standard
CZK
Decoration Panel 4-way blow
CZK
Sealing member of air discharge outlet
CZK
Long-life filter
CZK
Panel spacer
CZK
Fresh air intake kit
CZK
FWC-B
FWF-B
BYCQ140C
7.350,–
-
CE.KDDQ55C140
15.335,–
BYFQ60B
4.832,–
KDBH44BA60
3.963,–
KAFQ441BA60
on request
KDBQ44B60
13.542,–
KDDQ44XA60
4.543,–
BRC7F532F (11)
4.948,–
BRC7F533F (11)
3.502,–
BRC7E530 (11)
4.971,–
BRC7E531 (11)
8.189,–
KDBHQ55C140
3.010,–
KAFP551K160
2.865,–
-
Control Systems
Remote control Infrared H/P
CZK
Remote control Infrared C/O
CZK
Remote Control Wired
BRC315D (1)
3.153,–
DCS302C51 (2)
48.176,–
KJB311A
2.228,–
DCS301B51 (5)
20.283,–
KJB212A
2.141,–
DST301B51 (5)(8)
25.346,–
KRP2A52 (4)(8)
9.837,–
KRP4A53 (4)(8)
4.977,–
CZK
Central remote control
CZK
Electrical box with earth terminal (3 blocks)
CZK
Unified on/off control
CZK
Electrical box with earth terminal (2 blocks)
CZK
Shedule timer
CZK
Wiring adapter for electrical appendices 1
CZK
Wiring adapter for electrical appendices 2
CZK
Installation box for adapter PCB
CZK
Remote Sensor
CZK
KRP1H98 (9)
1.447,–
KRCS01-4
2.372,–
Intelligent touch controller
DCS601C51 (3)(7)
53.495,–
KJB411A
3.848,–
EKFCMBCB (4)(8)
2.893,–
EKMV2C09B (4)(6)(10)
2.401,–
EKMV3C09B (4)(6)(10)
2.721,–
EKRP1C11
2.230,–
CZK
Electrical installation box
CZK
Optional PCB for MOD-bus connection
CZK
2-way valve - On/Off
CZK
3-way valve - On/Off
CZK
Valve control PCB
CZK
Remote “On/Off ” and “forced off ” kit
CZK
KRP1BA101 (9)
1.919,–
KRCS01-1
2.371,–
EKRORO (12)
724,–
-
Notes:
1. Optional, electrical installation box with earth terminal KJB212A is required, if
controller wires need to be installed in the wall.
2. Requires electrical installation box with earth terminal KJB311A.
3. Requires electrical installation box KJB411A.
4. Requires installation box KRP1H98 for FWC-B and KRP1BA101 for FWF-B.
5. Requires electrical installation box with earth terminal KJB212A, if built in the wall.
6. Requires valve control PCB EKRP1C11.
7. I-touch:
• Not allowed to use the i-touch for an installation with both fan coils and VRV units.
• Can not be used in combination with fan coil units, that use MOD bus
communication.
• No Airnet or telephone connection possible.
8. Only 1 of these 4 options can be installed on 1 indoor unit.
9. FWC -B: Max. 1 KRP1H98 box can be mounted on the unit.
Max. 2 PCB’s can be mounted in 1 KRP1H98 box.
FWF-B: Max. 2 KRP1BA101 boxes can be mounted on the unit.
Max. 1 PCB can be mounted in 1 KRP1BA101 box.
10. FWC-B - 2-pipe unit: 1 x valve kit + 1 x installation box for PCB KRP1H98 + 1 x valve
control PCB EKRP1C11
FWC-B - 4-pipe unit: 2 x valve kit + 1 x installation box for PCB KRP1H98 + 1 x valve
control PCB EKRP1C11
FWF-B - 2-pipe unit: 1 x valve kit + 1 x installation box for PCB KRP1BA101 + 1 x valve
control PCB EKRP1C11.
FWF-B - 4-pipe unit: 2 x valve kit + 1 x installation box for PCB KRP1BA101 + 1 x valve
control PCB EKRP1C11.
11. It is possible to change the operation mode, but this will not have an impact on the
water temperature.
(No feed back to water source)
It is not possible to select the “auto air flow” setting.
Dry operation can be selected with this remote control, but this function is not
available on the FWC-B / FWF-B model.
12. This option is needed to create T1 T2 wire.
All options are supplied as kit.
21
→ FWV - D, Floor standing fan coil
▪ FWV - D
FAN COIL
Low Wall unit FWV
FWV**DTN, 2 pipe unit,
standard, without valve
FWV**DTV, 2 pipe unit,
with 3-way on/off 230V valve, factory mounted
FWV**DTD, 2 pipe unit, with simplified 3-way on/off
230V valve, factory mounted
Cooling capacity (Total)
Heating capacity (2-pipe at High Speed)
FWV**DFN, 4 pipe unit,
standard, without valves
FWV**DFV, 4 pipe unit, with 3-way on/off 230V valves,
factory mounted
FWV**DFD, 4 pipe unit, with simplified 3-way on/off
230V valves, factory mounted
Cooling capacity (Total)
Heating capacity (4-pipe at High Speed)
CZK
CZK
CZK
kW
kW
CZK
CZK
CZK
kW
kW
Factory mounted options
3-way on/off 24V valve
3-way proportional on/off valves
2-way on/off 230V valve
2-way on/off 24V valves
2-way proportional on/off valve
4-rows coil (for 2 pipe unit only)
6-speeds fan motor
Electric heater (for 2 pipe unit only)
CZK
CZK
CZK
CZK
CZK
CZK
CZK
CZK
Factory mounted options
FWEC1A
FWEC2A
FWEC3A
Standard version
Advanced version
Advanced Plus version
01
15
02
25
03
35
04
06
08
10
8.215,–
8.328,–
9.062,–
9.416,–
9.993,–
10.633,–
11.489,–
12.421,–
16.485,–
18.716,–
13.973,–
13.964,–
14.848,–
14.989,–
15.752,–
16.270,–
17.389,–
18.321,–
22.838,–
25.067,–
10.889,–
11.210,–
11.658,–
12.298,–
12.554,–
13.452,–
14.221,–
15.117,–
19.152,–
21.266,–
1,54
2,14
1,74
2,20
1,96
2,57
2,42
3,20
2,93
3,81
3,51
4,78
4,33
5,10
4,77
5,95
6,71
7,83
8,02
10,03
9.513,–
9.737,–
10.445,–
10.889,–
11.546,–
12.107,–
13.381,–
14.453,–
18.913,–
21.087,–
19.902,–
19.793,–
20.805,–
20.947,–
21.934,–
22.227,–
23.768,–
24.813,–
29.809,–
32.040,–
14.989,–
15.437,–
15.886,–
16.591,–
16.975,–
17.872,–
19.024,–
20.049,–
24.598,–
26.775,–
1,46
1,90
1,69
2,02
1,79
2,01
2,38
2,92
2,87
3,08
3,46
4,80
4,26
5,05
4,67
5,30
6,64
7,91
7,88
8,35
01
15
02
25
03
35
04
06
08
10
-
on r.
08
10
on request
on request
on request
on request
on request
on request
on request
on request
-
01
15
02
CZK
CZK
CZK
25
03
35
on request
on request
on request
Notes:
Accessories as kits are included on page 25.
Additional single row h/e (4-row coil) can not be used in combination with electric heater.
Independent power supply is necessary for 24 V valve. FWEC1/2/3A are not suitable to control 24 V valve.
Controller FWEC3A is necessary for proportional valve.
Cooling capacity is related to High Speed, standard unit.
22
04
06
→ FWL - D, Flexi type fan coil
▪ FWL - D
FAN COIL
Flexible unit FWL
FWL**DTN, 2 pipe unit,
standard, without valve
FWL**DTV, 2 pipe unit, with 3-way on/off 230V valve,
factory mounted
FWL**DTD, 2 pipe unit, with simplified 3-way on/off
230V valve, factory mounted
Cooling capacity (Total)
Heating capacity (2-pipe at High Speed)
FWL**DFN, 4 pipe unit,
standard, without valves
FWL**DFV, 4 pipe unit, with 3-way on/off 230V valves,
factory mounted
FWL**DFD, 4 pipe unit, with simplified 3-way on/off
230V valves, factory mounted
Cooling capacity (Total)
Heating (4-pipe at High Speed)
01
15
02
25
03
35
04
06
08
10
CZK
8.611,–
8.840,–
9.654,–
9.800,–
10.699,–
11.210,–
12.138,–
13.071,–
17.587,–
19.902,–
CZK
14.256,–
14.284,–
15.244,–
15.245,–
16.344,–
16.782,–
17.982,–
18.913,–
23.910,–
26.196,–
CZK
11.210,–
11.658,–
12.170,–
12.619,–
13.259,–
14.028,–
14.796,–
15.693,–
20.177,–
22.419,–
kW
kW
1,54
2,14
1,74
2,20
1,96
2,57
2,42
3,20
2,93
3,81
3,51
4,78
4,33
5,10
4,77
5,95
6,71
7,83
8,02
10,03
CZK
10.106,–
10.249,–
10.897,–
11.402,–
12.138,–
13.068,–
14.170,–
15.103,–
20.099,–
22.244,–
CZK
20.297,–
20.114,–
21.087,–
21.266,–
22.329,–
22.931,–
24.362,–
25.265,–
30.797,–
32.971,–
CZK
15.437,–
15.886,–
16.206,–
17.038,–
17.487,–
18.705,–
19.665,–
20.561,–
25.686,–
27.800,–
kW
kW
1,46
1,90
1,69
2,02
1,79
2,01
2,38
2,92
2,87
3,08
3,46
4,80
4,26
5,05
4,67
5,30
6,64
7,91
7,88
8,35
01
15
02
25
03
35
04
06
08
10
-
on r.
08
10
Factory mounted options
3-way on/off 24V valve
3-way proportional on/off valves
2-way on/off 230V valve
2-way on/off 24V valves
2-way proportional on/off valve
4-rows coil (for 2 pipe unit only)
6-speeds fan motor
Electric heater (for 2 pipe unit only)
CZK
CZK
CZK
CZK
CZK
CZK
CZK
CZK
Factory mounted options
FWEC1A
FWEC2A
FWEC3A
Standard version
Advanced version
Advanced Plus version
on request
on request
on request
on request
on request
on request
on request
on request
-
01
15
02
CZK
CZK
CZK
25
03
35
on request
on request
on request
Notes:
Accessories as kits are included on page 25.
Additional single row h/e (4-row coil) can not be used in combination with electric heater.
Independent power supply is necessary for 24 V valve. FWEC1/2/3A are not suitable to control 24 V valve.
Controller FWEC3A is necessary for proportional valve.
Cooling capacity is related to High Speed, standard unit.
23
04
06
→ FWM - D, Flexi concealed fan coil
▪ FWM - D
FAN COIL
Flexible concealed unit FWM
FWM**DTN, 2 pipe unit,
standard, without valve
FWM**DTV, 2 pipe unit, with 3-way on/off 230V valve,
factory mounted
FWM**DTD, 2 pipe unit, with simplified 3-way on/off
230V valve, factory mounted
Cooling capacity (Total)
Heating capacity (2-pipe at High Speed)
"FWM**DFN, 4 pipe unit,
standard, without valves
FWM**DFV, 4 pipe unit, with 3-way on/off 230V
valves, factory mounted
FWM**DFD, 4 pipe unit, with simplified 3-way on/off
230V valves, factory mounted
Cooling capacity (Total)
Heating capacity (4-pipe at High Speed)
CZK
CZK
CZK
kW
kW
CZK
CZK
CZK
kW
kW
Factory mounted options
3-way on/off 24V valve
3-way proportional on/off valves
2-way on/off 230V valve
2-way on/off 24V valves
2-way proportional on/off valve
4-rows coil (for 2 pipe unit only)
6-speeds fan motor
Electric heater (for 2 pipe unit only)
CZK
CZK
CZK
CZK
CZK
CZK
CZK
CZK
01
15
02
25
03
35
04
06
08
10
6.965,–
7.511,–
7.684,–
8.346,–
8.490,–
9.210,–
9.584,–
10.448,–
13.786,–
15.656,–
12.720,–
13.239,–
13.469,–
14.101,–
14.247,–
15.109,–
15.455,–
16.405,–
20.203,–
22.017,–
10.178,–
10.724,–
10.898,–
11.559,–
11.703,–
12.422,–
13.065,–
13.928,–
17.401,–
19.337,–
1,54
2,14
1,74
2,20
1,96
2,57
2,42
3,20
2,93
3,81
3,51
4,78
4,33
5,10
4,77
5,95
6,71
7,83
8,02
10,03
8.375,–
8.777,–
8.980,–
9.497,–
10.102,–
11.022,–
11.569,–
12.375,–
16.203,–
18.131,–
18.736,–
18.994,–
19.339,–
20.002,–
20.490,–
21.153,–
21.959,–
22.765,–
27.110,–
29.039,–
14.667,–
15.070,–
15.272,–
15.789,–
16.394,–
17.315,–
18.264,–
19.002,–
23.165,–
25.159,–
1,46
1,90
1,69
2,02
1,79
2,01
2,38
2,92
2,87
3,08
3,46
4,80
4,26
5,05
4,67
5,30
6,64
7,91
7,88
8,35
01
15
02
25
03
35
04
06
08
10
-
on r.
on request
on request
on request
on request
on request
on request
on request
on request
-
Notes:
Accessories as kits are included on page 25.
Additional single row h/e (4-row coil) can not be used in combination with electric heater.
Independent power supply is necessary for 24 V valve. FWEC1/2/3A are not suitable to control 24 V valve.
Controller FWEC3A is necessary for proportional valve.
Cooling capacity is related to High Speed, standard unit.
24
→ Accessories for FWV - FWL - FWM
▪ FWV – FWL – FWM
ACCESSORIES
Accessories as a kit for FWV/FWL/FWM
1
Additional heat exchanger
CZK
Electric heater
CZK
15
2-pipe 3-ways 230V on/off valve kit
CZK
4-pipe 3-ways 230V on/off valve kit
CZK
2-ways 230V on/off valve kit cooling h/e
CZK
2-ways 230V on/off valve kit additional h/e
CZK
2-pipe simplified 3-ways 230V on/off valve kit
CZK
4-pipe simplified 3-ways 230V on/off valve kit
CZK
2-pipe 3-ways 24V on/off valve kit
CZK
4-pipe 3-ways 24V on/off valve kit
CZK
2-pipe 3-ways proportional valve kit
CZK
4-pipe 3-ways proportional valve kit
CZK
2-ways 24V on/off valve kit cooling h/e
CZK
2-ways 24V on/off valve kit additional h/e
CZK
2-ways proportional valve kit cooling h/e
CZK
2-ways proportional valve kit additional h/e
CZK
Fan stop thermostat
CZK
Air intake & discharge grille
CZK
EAIDF02A6
4.629,–
Supporting feet
CZK
Supporting feet & grille
CZK
Fresh air intake
CZK
Rear panel
CZK
Plenum box with circular connections
(only for FWM-D)
CZK
Vertical auxiliary drainpan
CZK
Horizontal auxiliary drainpan
CZK
2
ESRH02A6
1.591,–
EEH01A6
EEH02A6
7.175,–
7.175,–
ESFVG02A6
810,–
EFA02A6
2.026,–
ERPV02A6
867,–
EPCC02A6
2.521,–
3
35
ESRH03A6
1.910,–
EEH03A6
7.696,–
E2MV03A6
5.006,–
E4MV03A6
9.372,–
E2MV2B07A6
2.632,–
E2MV2B07A6
2.632,–
E2MVD03A6
3.338,–
E4MVD03A6
6.131,–
E2M2V03A6
5.722,–
E4M2V03A6
10.218,–
E2MPV03A6
8.991,–
E4MPV03A6
16.553,–
E2M2V207A6
2.453,–
E2M2V207A6
2.453,–
E2MPV207A6
6.266,–
E2MPV207A6
6.266,–
YFSTA6
492,–
EAIDF03A6
5.699,–
ESFV06A6
492,–
ESFVG03A6
984,–
EFA03A6
2.055,–
ERPV03A6
1.187,–
EPCC03A6
2.793,–
EDPVB6
138,–
EDPHB6
138,–
Controller as a kit for FWV/FWL/FWM
ECFWMB6 Controller electromechanical, Built in
FWEC1A Wired remote controller, Standard version
FWEC2A Wired remote controller,
Advanced version
FWEC3A Wired remote controller,
Advanced Plus version
FWECKA On board mounting kit, for FWEC*A,
remote airprobe incl.
FWFCKA Wall mounting kit (spacing collar), for FWEC*A
FWTSKA Temperature sensor kit , for FWEC*A
FWHSKA Relative humidity sensor kit ,
for FWEC2A and FWEC3A
EPIMSB6 Master / Slave interface
25
all sizes
CZK
CZK
CZK
1.012,–
2.546,–
3.993,–
CZK
5.439,–
CZK
435,–
CZK
CZK
CZK
435,–
231,–
607,–
CZK
3.473,–
25
4
6
ESRH06A6
2.112,–
EEH06A6
8.015,–
E2MV06A6
5.353,–
E4MV06A6
9.767,–
E2MVD06A6
3.406,–
E4MVD06A6
6.266,–
E2M2V06A6
5.722,–
E4M2V06A6
10.218,–
E2MPV06A6
8.856,–
E4MPV06A6
16.621,–
8
10
ESRH10A6
2.807,–
EEH10A6
8.333,–
E2MV10A6
5.788,–
E4MV10A6
10.219,–
E2MV2B10A6
2.778,–
E2MVD10A6
3.406,–
E4MVD10A6
6.335,–
E2M2V10A6
6.063,–
E4M2V10A6
10.763,–
E2MPV10A6
9.128,–
E4MPV10A6
16.825,–
E2M2V210A6
2.453,–
E2MPV210A6
6.266,–
EAIDF06A6
7.118,–
ESFVG06A6
1.128,–
EFA06A6
2.286,–
ERPV06A6
1.331,–
EPCC06A6
3.474,–
EAIDF10A6
8.420,–
ESFV10A6
607,–
ESFVG10A6
1.562,–
EFA10A6
2.604,–
ERPV10A6
1.707,–
EPCC10A6
4.837,–
→ FWZ - A, Floor standing fan coil with DC fan motor
▪ FWZ - A
FAN COIL
Low sound level and up to 70% energy saving thanks to the BLDC motor technology
Low Wall unit with DC fan motor FWZ
FWZ**ATN, 2 pipe unit,
standard, without valve
FWZ**ATV, 2 pipe unit,
with 3-way on/off 230V valve, factory mounted
FWZ**ATD, 2 pipe unit, with simplified 3-way on/off
230V valve, factory mounted
Cooling capacity (Total)
Heating capacity (2-pipe at High Speed)
FWZ**AFN, 4 pipe unit,
standard, without valves
FWZ**AFV, 4 pipe unit, with 3-way on/off 230V valves,
factory mounted
FWZ**AFD, 4 pipe unit, with simplified 3-way on/off
230V valves, factory mounted
Cooling capacity (Total)
Heating capacity (4-pipe at High Speed)
CZK
CZK
CZK
kW
kW
CZK
CZK
CZK
kW
kW
Factory mounted options
3-way on/off 24V valve
2-way on/off 230V valve
2-way on/off 24V valves
4-rows coil (for 2 pipe unit only)
Electric heater (for 2 pipe unit only)
Advanced Plus version
03
06
08
13.259,–
14.028,–
16.206,–
20.242,–
18.704,–
19.473,–
21.843,–
26.327,–
16.078,–
16.847,–
19.153,–
23.380,–
2,64
3,47
4,96
6,40
6,32
7,51
10,08
11,18
14.412,–
15.309,–
18.192,–
22.291,–
24.277,–
25.174,–
28.056,–
32.732,–
20.049,–
20.946,–
24.085,–
28.505,–
2,43
2,46
4,96
4,19
6,32
6,45
10,08
10,06
02
03
06
08
06
08
CZK
CZK
CZK
CZK
CZK
Factory mounted options
FWEC3A
02
on request
on request
on request
on request
on request
02
03
CZK
on request
Notes:
Accessories as kits are included on page 29.
Additional single row h/e (4-row coil) can not be used in combination with electric heater.
Independent power supply is necessary for 24 V valve. FWEC3A are not suitable to control 24 V valve.
Controller FWEC3A is necessary to control DC fan motor.
Cooling capacity is related to High Speed, standard unit.
26
→ FWR - A, Flexi type fan coil with DC fan motor
▪ FWR - A
FAN COIL
Low sound level and up to 70% energy saving thanks to the BLDC motor technology
FLEXI type unit with DC fan motor FWR
FWR**ATN, 2 pipe unit,
standard, without valve
FWR**ATV, 2 pipe unit,
with 3-way on/off 230V valve, factory mounted
FWR**ATD, 2 pipe unit, with simplified 3-way on/off
230V valve, factory mounted
Cooling capacity (Total)
Heating capacity (2-pipe at High Speed)
FWR**AFN, 4 pipe unit,
standard, without valves
FWR**AFV, 4 pipe unit, with 3-way on/off 230V valves,
factory mounted
FWR**AFD, 4 pipe unit, with simplified 3-way on/off
230V valves, factory mounted
Cooling capacity (Total)
Heating capacity (4-pipe at High Speed)
02
03
06
08
CZK
13.836,–
14.989,–
17.295,–
22.099,–
CZK
19.281,–
20.434,–
22.932,–
28.184,–
CZK
16.654,–
17.807,–
20.242,–
25.174,–
kW
kW
2,64
3,47
4,96
6,40
6,32
7,51
10,08
11,18
CZK
15.117,–
16.334,–
19.153,–
24.341,–
CZK
24.982,–
26.199,–
29.081,–
34.782,–
CZK
20.754,–
21.971,–
25.110,–
30.554,–
kW
kW
2,43
2,46
4,96
4,19
6,32
6,45
10,08
10,06
02
03
06
08
06
08
Factory mounted options
3-way on/off 24V valve
2-way on/off 230V valve
2-way on/off 24V valves
4-rows coil (for 2 pipe unit only)
Electric heater (for 2 pipe unit only)
CZK
CZK
CZK
CZK
CZK
Factory mounted options
FWEC3A
Advanced Plus version
on request
on request
on request
on request
on request
02
03
CZK
on request
Notes:
Accessories as kits are included on page 29.
Additional single row h/e (4-row coil) can not be used in combination with electric heater.
Independent power supply is necessary for 24 V valve. FWEC1/2/3A are not suitable to control 24 V valve.
Controller FWEC3A is necessary to control DC fan motor.
Cooling capacity is related to High Speed, standard unit.
27
→ FWS - A, Flexi type fan coil with DC fan motor
▪ FWS - A
FAN COIL
Low sound level and up to 70% energy saving thanks to the BLDC motor technology
FLEXI type unit with DC fan motor FWS
FWS**ATN 2 pipe unit,
standard, without valve
FWS**ATV, 2 pipe unit,
with 3-way on/off 230V valve, factory mounted
FWS**ATD, 2 pipe unit, with simplified 3-way on/off
230V valve, factory mounted
Cooling capacity (Total)
Heating capacity (2-pipe at High Speed)
FWS**AFN 4 pipe unit,
standard, without valves
FWS**AFV 4 pipe unit, with 3-way on/off 230V valves,
factory mounted
FWS**AFD, 4 pipe unit, with simplified 3-way on/off
230V valves, factory mounted
Cooling capacity (Total)
Heating capacity (4-pipe at High Speed)
CZK
CZK
CZK
kW
kW
CZK
CZK
CZK
kW
kW
Factory mounted options
3-way on/off 24V valve
2-way on/off 230V valve
2-way on/off 24V valves
4-rows coil (for 2 pipe unit only)
Electric heater (for 2 pipe unit only)
Advanced Plus version
03
06
08
11.850,–
12.683,–
14.541,–
18.128,–
17.359,–
18.128,–
20.177,–
24.213,–
14.669,–
15.501,–
17.551,–
21.266,–
2,64
3,47
4,96
6,40
6,32
7,51
10,08
11,18
13.067,–
14.220,–
16.334,–
20.370,–
22.996,–
24.085,–
26.199,–
30.811,–
18.704,–
19.857,–
22.227,–
26.519,–
2,43
2,46
4,96
4,19
6,32
6,45
10,08
10,06
02
03
06
08
06
08
CZK
CZK
CZK
CZK
CZK
Factory mounted options
FWEC3A
02
on request
on request
on request
on request
on request
02
03
CZK
on request
Notes:
Accessories as kits are included on page 29.
Additional single row h/e (4-row coil) can not be used in combination with electric heater.
Independent power supply is necessary for 24 V valve. FWEC3A are not suitable to control 24 V valve.
Controller FWEC3A is necessary to control DC fan motor.
Cooling capacity is related to High Speed, standard unit.
28
→ Accessories for FWZ - FWR - FWS
▪ FWZ - FWR - FWS
ACCESSORIES
Accessories as a kit for FWZ/FWR/FWS
Additional heat exchanger
CZK
Electric heater
CZK
02
03
06
08
ESRH02A6
1.591,–
EEH02A6
7.175,–
ESRH03A6
1.910,–
EEH03A6
7.696,–
ESRH06A6
2.112,–
EEH06A6
8.015,–
E2MV06A6
5.353,–
E4MV06A6
9.767,–
ESRH10A6
2.807,–
EEH10A6
8.333,–
E2MV10A6
5.788,–
E4MV10A6
10.219,–
E2MV2B10A6
2.778,–
E2MVD06A6
3.406,–
E4MVD06A6
6.266,–
E2M2V06A6
5.722,–
E4M2V06A6
10.218,–
E2MVD10A6
3.406,–
E4MVD10A6
6.335,–
E2M2V10A6
6.063,–
E4M2V10A6
10.763,–
E2M2V210A6
2.453,–
EAIDF06A6
7.118,–
EAIDF10A6
8.420,–
ESFV10A6
607,–
ESFVG10A6
1.562,–
EFA10A6
2.604,–
ERPV10A6
1.707,–
EPCC10A6
4.837,–
2-pipe 3-ways 230V on/off valve kit
E2MV03A6
5.006,–
E4MV03A6
9.372,–
CZK
4-pipe 3-ways 230V on/off valve kit
CZK
2-ways 230V on/off valve kit cooling h/e
E2MV2B07A6
2.632,–
CZK
2-ways 230V on/off valve kit additional h/e
E2MV2B07A6
2.632,–
CZK
2-pipe simplified 3-ways 230V on/off valve kit
E2MVD03A6
3.338,–
E4MVD03A6
6.131,–
E2M2V03A6
5.722,–
E4M2V03A6
10.218,–
CZK
4-pipe simplified 3-ways 230V on/off valve kit
CZK
2-pipe 3-ways 24V on/off valve kit
CZK
4-pipe 3-ways 24V on/off valve kit
CZK
2-ways 24V on/off valve kit cooling h/e
E2M2V207A6
2.453,–
CZK
2-ways 24V on/off valve kit additional h/e
E2M2V207A6
2.453,–
CZK
Air intake & discharge grille
CZK
EAIDF02A6
4.629,–
EAIDF03A6
5.699,–
ESFV06A6
492,–
ESFVG03A6
984,–
EFA03A6
2.055,–
ERPV03A6
1.187,–
EPCC03A6
2.793,–
Supporting feet
CZK
Supporting feet & grille
CZK
Fresh air intake
CZK
Rear panel
CZK
Plenum box with circular connections
(only for FWS-A)
CZK
ESFVG02A6
810,–
EFA02A6
2.026,–
ERPV02A6
867,–
EPCC02A6
2.521,–
Vertical auxiliary drainpan
EDPVB6
138,–
EDPHB6
138,–
CZK
Horizontal auxiliary drainpan
CZK
Controller as a kit for FWZ / FWR / FWS
FWEC3A
FWECKA
FW FCKA
FWTSKA
FWHSKA
Wired remote controller,
Advanced Plus version
On board mounting kit, for FWEC*A,
remote airprobe incl.
Wall mounting kit (spacing collar), for
FWEC*A
Temperature sensor kit,
for FWEC*A
Relative humidity sensor kit ,
for FWEC2A and FWEC3A
ESFVG06A6
1.128,–
EFA06A6
2.286,–
ERPV06A6
1.331,–
EPCC06A6
3.474,–
all sizes
CZK
5.439,–
CZK
435,–
CZK
435,–
CZK
231,–
CZK
607,–
29
→ Overview: Air cooled chiller portfolio
Extra low
Reduced
Low
Standard
Sound version
High ambient
Premium
High
Standard
Efficiency version
Screw
Scroll
Swing
Free cooling
Inverter
Refrigerant
Compressor
INVERTER
Cooling only
0
EWAQ~ADVP
R-410A
3
EWAQ~ACV3/ACW1
R-410A
3
EUWA*~KBZW1
R-407C
EWAQ~BA*
R-410A
EWAQ~DAYN
3
3
3
3
3
3
3
3
3
3
3
R-410A
3
3
3
EWAQ~E-
R-410A
3
EWAQ~F-
R-410A
3
EWAQ~GZ NEW
R-410A
EWAD~E-
R-134a
3
3
EWAD~D-
R-134a
3
3
3
EWAD~BZ
R-134a
3
3
3
R-134a
3
3
3
EWAD~TZ NEW
*
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
R-134a
3
3
3
3
Heat pump
0
EWYQ~ADVP
R-410A
3
3
3
EWYQ~ACV3/ACW1
R-410A
3
3
3
3
EUWY*~KBZW1
R-407C
3
3
3
EWYQ~BA*
R-410A
3
3
3
EWYQ~DAYN
R-410A
3
3
3
EWYQ~F NEW
R-410A
3
3
3
EWYQ~GZ NEW
R-410A
3
3
3
3
EWYD~BZ
R-134a
3
3
3
3
3
3
3
3
3
3
3
3
3
3
Condensing unit
ERAD~E-
3
3
3
3
3
3
3
R-134a
R-134a
3
3
EWAD~CZ
EWAD~CF
3
3
R-134a
*
3
3
EWAD~C-
EWAD~DZ COMING
SOON
3
0
R-134a
* : preliminary
30
Capacity classes (kW)
17,5
200
500
1.000
2.000
5,2~
7,1
8,6~17,0
11,2~56,1
16,6~64,5
79,4~256
172~334
165~672
80~350
98~411
177~620
328~513
200~700
617~2.008
631~1.795
540~1.785
602~1.555
17,5
200
500
1.000
2.000
500
1.000
2.000
5,2~7,1
5,65~7,75
8,5~17,0
9,9~14,8
9,05~50,9
11,4~54,2
16,6~64,5
16,2~63,7
76,6~254
86,5~283
158~624
173~674
80~350
80~350
247~580
271~618
17.5
200
116~488
31
→ Overview: Portfolio Water cooled and Condenserless units
Sound version
Standard
High
Standard
Efficiency version
Centrifugal
Screw
Scroll
Inverter
Refrigerant
Compressor
INVERTER
Water cooled chillers (Cooling only & Heating only)
3
3
3
3
3
R-134a
3
3
3
3
EWWD~I-
R-134a
3
3
3
3
EWWD~H-
R-134a
3
3
3
R-410A
3
3
3
EWWP~KBW1N
R-407C
EWWD~J-
R-134a
EWWD~G-
3
Water cooled chillers (Cooling only)
EWWQ~B-
3
Condenserless chillers
3
3
3
3
3
R-134a
3
3
3
R-134a
3
3
3
EWLP~KBW1N
R-407C
EWLD~J-
R-134a
EWLD~GEWLD~I-
3
Water cooled centrifugal chillers
EWWD~FZ
R-134a
3
3
3
3
DWME
R-134a
3
3
3
3
DWSC
DWDC
R-134a
optional
3
3
3
6.000 RT
NEW
CENTRIFUGAL
R-134a
3
3
3
▪ Large Chillers options and accessories summary
Depending on the type and size of chiller a wide range of options and accessories is available. E.g.
Brine (glycol) application
Flow switch for evaporator
Dual set point possibility
Star delta compressor starter
(kit for field installation)
Set point reset and demand limit possibility
Thermal relays for compressors
Victaulic connections
General fault contact
Thermal relays for fans
Rubber type ant vibration mounts
Single pump
Under/over voltage controller
Evaporator heater
Twin pump
Phase monitor device
Main switch
Total heat recovery
Condenser coils with special
Suction and discharge stop valves
Partial heat recovery
anti corrosion treatment
on compressors
Low ambient application
32
Capacity classes (kW)
0
17,5
200
500
1.000
2.000 21.800
1.000
2.000 21.800
1.000
2.000 21.800
1.000
2.000 21.800
12,9~194
16,7~249
120~568
142~681
165~602
221~785
332~1.503
424~1.951
368~1.212
454~1.488
0
17,5
200
500
379~2.156
0
17,5
200
500
12,1~62,4
109~528
160~524
315~1.433
0
17,5
200
500
316~1.054
1.400~
1.900
300~4.500
600~9.000
[ 2 x 10.900 ] 21.800
Daikin Europe N.V. participates in the Eurovent Certification
programme for Air conditioners (AC), Liquid Chilling Packages (LCP),
Air handling units (AHU) and Fan coil units (FCU), Check ongoing
validity of certificate online: www.eurovent-certification.com or
using: www.certiflash.com
Air cooled: Eurovent certified up to 600kW
Water cooled: Eurovent certified up to 1500kW
Nominal cooling capacities are based on Eurovent conditions:
Evaporator: 12°C/7°C — Ambient: 35°C
Nominal heating capacities are based on Eurovent conditions:
Ambient: 7°CDB/6°CWB — Condenser: 40°C/45°C
Power factor 0.9 correction device
High ESP fans
Plant Watch PRO monitoring system
A/V meter
Cu/Ni heat exchanger
Remote user interface
Coil guards
Dual pressure relieves safety valves
Soft starter
Different address card
Low noise version
Different bus communication gateways (LonTalk,
Refrigerant Gauges
Bacnet, Modbus,…)
For the exact availability of the chiller which fits best
Coil guards
Chiller Sequencing Panel
your application please get in contact with your
Cu/Cu condenser coils
Different Modems (fixed and GSM)
Daikin sales responsible.
33
→ Total solution products
▪ AIR COOLER
▪ COOLING TOWER
On request we can offer you the most suitable air cooler for
your application based on a brine/water solution.
On request we can offer you the most
suitable cooling tower for your application.
For correct selection we need following info:
1-162 KW
▪
70-9.200 KW
• Heat rejection capacity (kW) or chiller type
and working conditions
• Liquid inlet and outlet temperature
• Liquid type
• Maximum/Minimum ambient temperature
• Maximum sound level
• Space restrictions
AIR HANDLING UNIT
3
500-140.000 M /H
On request we can offer you the most suitable air handling
unit for your application.
• Air handling units for filtering, heating, cooling, humidifying,
and air drying
• Air handling units with heat recovery
• Air handling units for outdoor installation
• Air handling units in hygienic execution for hospital and
clean room
• Air handling units with indirect gas fired heating
• Air handling units for swimming pool applications
• Air handling units with higher air volumes manufactured on
request
• Air handling units with thermal uncoupled frame
▪ COMPRESSOR
INSPECTION/REPAIR/OVERHAUL
To extend the lifetime of your compressor,
Daikin offers a compressor overhaul service
as preventive maintenance.
In case of broken compressor, Daikin can
offer an inspection to determine whether
the compressor is repairable or not. Based
on the findings the broken parts will be
replaced and the compressor will be
restored into operational condition.
▪ DRY COOLER & CONDENSER
3-2.400 KW
On request we can offer you the most suitable dry cooler and
condenser for your application.
For correct selection we need following info:
Inspection
Inspection fee/compressor*
on request
• Heat rejection capacity (kW) or chiller type and working
conditions
• Liquid inlet and outlet temperature (dry cooler)
• Liquid type (dry cooler)
• Condensing temperature (condenser)
• Refrigerant type and number of circuits (condenser)
• Maximum/Minimum ambient temperature
• Maximum sound level
• Space restrictions
Repair
Repair cost/compressor*
After inspection, on quotation base
Overhaul
Overhaul cost/compressor*
on request
Remarks
The above is only valid for DAIKIN semi-hermetic compressors
* Excluding transport cost and other site related costs
→ Measuring conditions
Mentioned Capacities, Efficiency Ratios, Sound power levels, Dimensions, Weights are indicative and valid under the following conditions:
Chillers
Air cooled units
Condenserless units
Water cooled units
Cooling
Heating
Heat recovery
Cooling
Cooling
Heating
7 °C / 12 °C water
40 °C / 45 °C water
7 °C / 12 °C water
7 °C / 12 °C water
7 °C / 12 °C evaporator water
7 °C / 12 °C evaporator water
35 °C ambient temp
7 °C ambient temp
35 °C ambient temp
40°C / 45°C heat recovery
45 °C condensing temp / 5 K subcooling
30 °C / 35 °C condenser water
40 °C / 45 °C condenser water
Cooling:
Heating:
indoor temperature: 27 °C db / 19 °C wb
indoor temperature: 20 °C db
outdoor temperature: 35 °C
outdoor temperature: 7 °C db / 6 °C wb
Cooling:
Heating:
General:
evaporation temperature: 6 °C
condensing temperature: 46 °C
evaporator superheat: 5K
condenser sub-cool: 3K
7,5 m equivalent refrigerant piping
0 m level difference
outdoor temperature: 35 °C
outdoor temperature: 7 °C
Cooling:
Room temperature DB/WB: 27 °C/19 °C
Entering/Leaving water temperature: 7 °C/12 °C
Room temperature: 20 °C
Entering water temperature: 50 °C (2-pipe,water flow rate same as for the cooling) / 70 °C (4-pipe, water temperature leaving 60°C)
Rooftops
Condensing units
on-coil temperature: 27 °CDB / 19 °CWB
on-coil temperature: 20 °CDB
Fan coil units
Heating:
34
→ Všeobecné obchodní podmínky
I. OBECNÁ USTANOVENÍ
1. Všechna práva a povinnosti ze smluv, v nichž má společnost DAIKIN AIRCONDITIONING CENTRAL EUROPE –
CZECH REPUBLIC spol. s r.o., se sídlem Praha 8, Pobřežní 3, PSČ 186 00, IČ: 480 39 497, zapsaná v obchodním
rejstříku vedeném Městským soudem v Praze, oddílu C, vložce 15503 (dále jen „DAIKIN“) postavení prodávajícího
(dodavatele), a druhá smluvní strana postavení kupujícího (objednatele) (dále jen „zákazník“), jejichž předmětem je
prodej (dodání) jakéhokoliv zboží (dále souhrnně jen „zboží“) DAIKINem zákazníkovi, které nejsou odchylně upraveny
příslušnou smlouvou, se řídí těmito všeobecnými obchodními podmínkami.
2. Pro dodávky a plnění DAIKIN jsou rozhodující výhradně níže uvedené všeobecné obchodní podmínky DAIKIN.
Potvrzení zákazníka s odkazem na jeho obchodní nebo nákupní podmínky jsou aplikovatelné pouze v rozsahu,
v jakém jsou shodné s těmito všeobecnými obchodními podmínkami. Odchylné doplňky a změny vyžadují ke své
právní účinnosti výslovný souhlas DAIKIN a písemnou formu.
3. Tyto Všeobecné obchodní podmínky je možné si stáhnout na domovské stránce www.daikin.cz, jmenovitě na odkazu
(Všeobecné obchodní podmínky) „VOP“.
4. K iniciování procesu uzavření smlouvy na dodávku zboží mezi DAIKINem a zákazníkem může dojít jedním z následujících způsobů:
i. písemnou (dopisem, faxem nebo e-mailem) nabídkou DAIKINu na dodání zboží doručenou zákazníkovi; a/nebo
ii. písemnou (dopisem, faxem nebo e-mailem) objednávkou zboží zákazníka doručenou DAIKINu.
5. Zákazník uzavřením smlouvy s DAIKINem výslovně přijímá veškerá ustanovení těchto všeobecných obchodních
podmínek. Pro vyloučení pochybností se vylučuje uplatnění ustanovení § 1799 a 1800 zákona č. 89/2012 Sb., občanského zákoníku, ve znění pozdějších předpisů (dále jen „občanský zákoník“). Veškerá ujednání v rámci konkrétní
smlouvy odpovídají obchodním zvyklostem a zásadě poctivého obchodního styku.
7.
DAIKIN je oprávněn účtovat zákazníkovi náklady vzniklé prodlením s převzetím zboží, zejména, ale nikoliv pouze,
náklady na skladování (skladné 250,-Kč / 1 paleta zboží/1 týden), marné jízdy a dopravné dle tarifů k přepravě zboží
použitého přepravce.
VIII. VÝHRADA VLASTNICTVÍ
1. Dodané zboží zůstává vlastnictvím DAIKINu až do úplného zaplacení ceny zboží zákazníkem.
2. Zákazník je povinen písemně upozornit každou třetí osobu, která by chtěla nakládat a/nebo nakládá se zbožím (a to
jak v právním, tak i faktickém smyslu), k němuž má DAIKIN výhradu vlastnictví, že toto zboží je ve vlastnictví DAIKINu
a zabránit třetí osobě v nakládání s takovým zbožím.
3. Zákazník není rovněž oprávněn se zbožím s výhradou vlastnictví DAIKIN nakládat jiným způsobem neslučitelným
s výhradou vlastnictví DAIKIN (např.: zajišťovací převod vlastnického práva, zastavení zboží).
4. O zabavení nebo jiných omezeních zboží s výhradou vlastnictví DAIKINu je zákazník povinen DAIKIN bez zytečného
odkladu, nejpozději však do následujícího pracovního dne, písemně vyrozumět. Jakékoliv související náklady hradí
zákazník.
5. Uplatnění § 2133 občanského zákoníku se vylučuje.
IX. ZÁRUKA A ODPOVĚDNOST
A. Za vady příp. absenci garantovaných vlastností odpovídá DAIKIN s vyloučením dalších nároků, není-li v konkrétním
případě se zákazníkem písemně dohodnuto jinak, takto:
1. Záruční doba činí – není-li dále uvedeno jinak - 36 měsíců ode dne dodání zboží.
2. Záruka je poskytována a zákazník má nárok na záruční plnění pouze za předpokladu, že zboží dodané DAIKINem
zákazníkovi je instalováno a zároveň uvedeno do provozu přímo společností DAIKIN či osobou vyškolenou a písemně
pověřenou k provádění těchto činností společností DAIKIN, a to v souladu s návodem DAIKIN, a zároveň je bez
výjimky dodržován pravidelný servis a údržba zboží v souladu se servisními pokyny společnosti DAIKIN. U chladicích
jednotek se spirálovými kompresory typu EWAQ-E/EWAQ-F a se šroubovými kompresory je, není-li dohodnuto jinak,
zákazníkovi poskytována záruka v délce 12 měsíců, a to pouze v případě, když uvedení do provozu provádí společnost DAIKIN sama – v opačném případě není poskytována zákazníkovi žádná záruka. U produktů označených „J&E
Hall International for Daikin“ je zákazníkovi poskytována záruka v délce 18 měsíců. U produktů označených „Rotex“
činí zákazníkovi poskytovaná záruka obecně 24 měsíců, avšak s následující výjimkami: na produkty Rotex HPSU
je zákazníkovi poskytnuta materiálová záruka 24 měsíců od data uvedení do provozu, maximálně však 27 měsíců
od data fakturace s tím, že v případě pravidelné údržby a servisu dle pokynů DAIKINu dostupných na domovské
internetové stránce www.daikin.cz se poskytuje zákazníkovi prodloužená záruka 60 měsíců od uvedení do provozu,
maximálně však 63 měsíců od data fakturace. Pravidla záruky uvedená v předchozí větě za dvojtečkou se aplikují
rovněž na produkty označené jako Daikin Altherma, avšak u produktů označených jako Daikin Altherma Flex pouze
tehdy, pokud toto zařízení uvede do provozu DAIKIN sama. Materiálovou zárukou se pro účely těchto Všeobecných
obchodních podmínek rozumí: Dodávka originálních dílů Daikin přesně specifikovaných dle technických parametrů
zařízení a spol. DAIKIN odsouhlasených.
3. V případě vad zboží, na něž se vztahuje záruka, se DAIKIN zavazuje, že vadné zboží příp. vadné díly podle volby
DAIKIN vymění nebo opraví. Nároky na záruční plnění nad rámec těchto Všeobecných obchodních podmínek nebo
jakékoli jiné nároky ze záruky neexistují. Pracovní doba, doba strávená na cestě nebo jiné náklady se nenahrazují.
4. Záruka a/nebo odpovědnost DAIKINu jsou vyloučeny, jestliže zákazník písemně neoznámí zjevné vady zboží do 3
pracovních dnů po dodání zboží, ostatní vady bez zbytečného odkladu po zjištění.
5. Záruka a/nebo odpovědnost DAIKIN je navíc k případům uvedeným v odst. 2. a 4. vyloučena zejména v případě vad
zboží, které vznikly nevhodným nebo neodborným užíváním nebo zacházením se zbožím, nedodržováním provozních
podmínek nebo servisních směrnic, nadměrným namáháním nebo nevhodnými provozními prostředky nebo nevhodnými výměnnými látkami.
6. K provedení veškerých nutných záručních zásahů musí být DAIKINu ze strany zákazníka poskytnut potřebný čas
a součinnost. DAIKIN se zavazuje vyvinout veškeré úsilí, aby započal s odstraňováním vady zboží, za níž odpovídá,
v co nejkratším termínu. Při dalším používání vadného zboží se záruka a/nebo odpovědnost DAIKINu vztahuje pouze
na původní vadu. Náklady na odstranění vad zboží, provedené bez písemného předchozího souhlasu DAIKIN třetí
osobou, se nenahrazují. Odpovědnost za následky takových odstraňování vad je ze strany DAIKINu vyloučena.
7. Záruční doba pro náhradní díly činí 6 měsíců od dodání.
8. Při odstranění vady nezačíná běžet záruční doba pro vyměněné nebo opravené díly znovu.
9. V případě, že je zákazník v prodlení s úhradou ceny zboží, není DAIKIN povinen odstranit zákazníkem uplatněné vady
zboží, za něž DAIKIN odpovídá, a to až do okamžiku, dokud zákazník nesplní své platební závazky vůči DAIKINu.
Zákazník není oprávněn, ani při oprávněných reklamacích, z tohoto důvodu pozastavit platbu ceny zboží či jiné
splatné platby vůči DAIKINu.
10. Při dodání a montáži cizích výrobků se záruka omezuje na postoupení nároků na záruční plnění, které má DAIKIN vůči
dodavatelům cizího výrobku. Další nároky zákazníka na záruční plnění, zejména na snížení ceny, jsou vyloučeny.
11. V případě vyřešení uplatněné reklamace (ať již z titulu vad zboží při předání či z titulu vad zboží, za něž DAIKIN
odpovídá ze záruky) výměnou zboží či jeho části vyměněné zboží či jeho část přechází do vlastnictví DAIKIN, a to na
základě výlučného uvážení a rozhodnutí DAIKINu.
12. Jakékoliv reklamace či nároky z titulu vad krytých zárukou je zákazník povinen uplatnit u DAIKINu písemně.
B. Na náhradu újmy se uplatní obecné právní předpisy s tím, že právo zákazníka na náhradu újmy, resp. výše náhrady újmy
ze strany DAIKINu se omezuje maximální částkou rovnající se kupní ceně zboží, s jehož dodáním DAIKINem zákazníkovi
předmětná újma souvisí (v důsledku jehož dodání DAIKINem zákazníkovi újma vznikla). Omezení uvedené v předchozí
větě se nevztahuje na právo zákazníka na náhradu újmy způsobené DAIKINem v případech uvedených v ustanovení
§ 2898 občanského zákoníku.
II. NABÍDKA
1. Není- li v nabídce DAIKIN výslovně uvedeno jinak, nabídky DAIKIN jsou otevřené, orientační a nezávazné. Není-li
v nabídce DAIKIN výslovně uvedeno jinak, údaje o mírách, hmotnostech, technických datech, množství a dodacích
lhůtách jsou pouze orientační.
2. Ústní a telefonické dohody a ujednání musí být DAIKINem a zákazníkem písemně (dopisem, faxem nebo e-mailem)
potvrzeny.
III. OBJEDNÁVKY
1. Zákazník je povinen objednávat u DAIKINu zboží písemně (dopisem, faxem nebo e-mailem).
2. Ústní a telefonické dohody a ujednání musí být DAIKINem a zákazníkem písemně (dopisem, faxem nebo e-mailem)
potvrzeny.
IV. ZMĚNA PŘEDMĚTU PLNĚNÍ
1. Zrušení celé DAIKINem již akceptované objednávky nebo její části zákazníkem, příp. změna DAIKINem již akceptované objednávky zákazníkem jsou přípustné pouze s předchozím písemným souhlasem DAIKINu. V případě zrušení
celé DAIKINem již akceptované objednávky nebo její části zákazníkem, příp. při změně DAIKINem již akceptované
objednávky zákazníkem je DAIKIN vedle již poskytnutých plnění a vzniklých nákladů oprávněn účtovat zákazníkovi
stornopoplatek ve výši 20% sjednané kupní ceny (ceny díla) zakázky včetně DPH, nejméně však 7 000 Kč. Pro
specifické produktové skupiny zboží (např. „multiple scroll and screw chiller“) se aplikují zvláštní podmínky na zrušení
DAIKINem již akceptované objednávky nebo její části zákazníkem, příp. změnu DAIKINem již akceptované objednávky zákazníkem, které jsou dostupné na www.daikin.cz, (v sekci „VOP“).
2. Pravidla uvedená v čl. IV odst. 1 těchto Všeobecných obchodních podmínek se plně uplatní i na případy, kdy smlouva
na dodávku zboží byla mezi DAIKINem a zákazníkem uzavřena na základě nabídky DAIKINu ve smyslu čl. I odst. 4
písm. i a čl. II těchto Všeobecných obchodních podmínek.
3. V případě, že bude proti zákazníkovi zahájeno insolvenční řízení a/nebo zákazník vstoupí do likvidace, je DAIKIN
oprávněn od smlouvy odstoupit a/nebo pozastavit plnění veškerých svých závazků ze smlouvy, a to až do doby, než
zákazník řádně splní veškeré své povinnosti ze smlouvy pro něj vyplývající, a to aniž by DAIKIN byl povinen nahradit
zákazníkovi případně vzniklou újmu.
V. CENY A PLATEBNÍ PODMÍNKY
1. Kupní cena zboží (cena díla) (dále jen „cena“) se sjednává ve výši:
i. v případě, že je smlouva na dodávku zboží mezi DAIKINem a zákazníkem uzavírána na základě nabídky DAIKINu
ve smyslu čl. I odst. 4 písm. i a čl. II těchto Všeobecných obchodních podmínek, ve výši uvedené v takové nabídce
DAIKINu; ii. v případě, že je smlouva na dodávku zboží mezi DAIKINem a zákazníkem uzavírána na základě
objednávky zákazníka ve smyslu čl. I odst. 4 písm. ii a čl. III těchto Všeobecných obchodních podmínek, dle ceníků
a “Dohody o vzájemné spolupráci“ s DAIKINem platných ke dni objednání zboží zákazníkem. Ceníky DAIKIN se
zpravidla aktualizují jednou ročně. Změny cen DAIKINem však zůstávají vyhrazeny i v průběhu roku. DAIKIN je
tedy oprávněn jednostranně měnit ceníky zboží a zavazuje se seznámit kupujícího s platnými ceníky (dopisem,
emailem, faxem či publikací nového ceníku na domovské internetové stránce DAIKINu www.daikin.cz). Zákazník
cenu zboží dle nového ceníku akceptuje svou objednávkou učiněnou za platnosti a účinnosti nového ceníku, který
byl DAIKINem zákazníkovi oznámen a/nebo zpřístupněn (tj. např. tím, že zákazník objedná u DAIKINu zboží poté,
co bude nový platný ceník poslán zákazníkovi anebo publikován na domovské internetové stránce DAIKINu ve
smyslu výše uvedeného).
2. Ceny se rozumí netto bez jakýchkoli daní, poplatků nebo odvodů v uvedené měně včetně balného, není-li uvedeno
jinak, na předem ve smlouvě dohodnuté místo určení. DAIKIN nepřijímá zpět jakékoliv obaly a balicí materiál.
3. Není- li v konkrétní smlouvě výslovně sjednáno jinak, je zákazník povinen zaplatit DAIKINu cenu zboží na základě
DAIKINem vystavené faktury.
4. DAIKIN si vyhrazuje právo na částečná vyúčtování.
5. K reklamacím faktur, doručeným DAIKINu později než 2 týdny po obdržení faktury, se nepřihlíží. Není-li uvedeno
v konkrétním případě jinak, činí splatnost faktur 30 dní od data vystavení faktury, přičemž dnem platby je den připsání
příslušné fakturované platby beze srážek na účet DAIKINu. V případě prodlení zákazníka s úhradou ceny je zákazník
povinen uhradit DAIKINu smluvní pokutu ve výši 0,05% denně z dlužné částky za každý i započatý den prodlení. Tím
není dotčeno právo DAIKINu na náhradu škody v plném rozsahu. Dále je DAIKIN v případě prodlení zákazníka oprávněn požadovat po zákazníkovi náhradu veškerých nákladů spojených s vymáháním pohledávky, zejména výlohy na
upomínky a inkasní náklady a zákazník je povinen tyto na výzvu DAIKINu nejpozději do pěti (5) dnů v plné výši uhradit.
6. V případě sjednání splátek na úhradu ceny se DAIKIN a zákazník ve smyslu § 1931 občanského zákoníku dohodli,
že nesplní-li zákazník některou splátku, má DAIKIN právo na vyrovnání celé pohledávky. Toto právo může DAIKIN
uplatnit nejpozději do splatnosti nejblíže příští splátky.
7. DAIKIN je oprávněn podmínit expedici zboží platbou předem, a to v jakékoliv výši až do 100% ceny.
8. Zákazník není oprávněn bez předchozího písemného souhlasu DAIKIN zadržovat platby a/nebo jednostranně započítat jakékoliv své pohledávky za DAIKINem na cenu zboží či jakoukoliv jinou pohledávku DAIKINu za zákazníkem.
X. VRÁCENÍ ZBOŽÍ
1. Zákazník je oprávněn zboží vrátit a/nebo vyměnit pouze na základě předchozího písemného souhlasu DAIKINu,
přičemž i v případě, že se DAIKIN dle svého výlučného uvážení rozhodne vratku zboží akceptovat, akceptuje vrácení
zboží pouze v min. hodnotě 2 500 Kč bez DPH a max. hodnotě 1 250 000 Kč bez DPH za předpokladu, že toto zboží
není poškozeno, nebylo použito, je zabaleno v originálních obalech a je v takových podmínkách umožňujících jeho
další prodej. Zejména vrácení již nainstalovaného zboží (včetně chillerů) a speciálně vyrobených produktů (zboží)
včetně náhradních dílů nebude v žádném případě ze strany ze strany DAIKINu akceptováno.
2. V případě, že si zákazník přeje vznést návrh na vrácení a/nebo výměnu zboží ve smyslu čl. X odst. 1 těchto Všeobecných
obchodních podmínek, je povinen vyplnit formulář „Požadavek na vrácení zboží“, dostupný na www.daikin.cz
a doručit jej (faxem nebo mailem) do DAIKINu na jím určenou adresu nejpozději do 10 dnů od dodání zboží.
3. Zákazník je v případě, že DAIKIN souhlasil s vrácením a/nebo výměnou zboží ve smyslu čl. X odst. 1 těchto
Všeobecných obchodních podmínek, povinen doručit zboží na své nebezpečí a náklady do místa určeného
DAIKINem.
4. V každém případě vrácení a/nebo výměny zboží bude zákazníkovi dobropisováno maximálně 80% ceny bez DPH, za
níž DAIKIN toto zboží prodal zákazníkovi. Všechny standardní vratky budou předmětem poplatků za přeskladnění /
administrativních poplatků ve výši 20% z ceny dotčeného zboží bez DPH.
5. Všechny vratky zboží DAIKIN prověří. Jestliže zboží není vráceno v souladu s těmito Všeobecnými obchodními podmínkami (viz. čl. X odst. 1 - 4 těchto Všeobecných obchodních podmínek), je DAIKIN oprávněn bez dalšího odmítnout
vratku zboží a vrátit zboží zpět zákazníkovi na náklady a nebezpečí zákazníka. Alternativně k uvedenému v předchozí
větě je DAIKIN oprávněn účtovat zákazníkovi vyšší náklady na přeskladnění zboží / admininstrativní poplatky než je
20% z ceny dotčeného zboží bez DPH uvedených v čl. X odst. 4 těchto Všeobecných obchodních podmínek.
6. Jakýkoliv DAIKINem vystavený dobropis, resp. pohledávka zákazníka za DAIKINem z takto vystaveného dobropisu,
bude vždy započtena oproti pohledávkám DAIKINu za zákazníkem, které vzniknou z budoucích dodávek zboží
DAIKINem zákazníkovi, a tedy žádná jiná forma úhrady pohledávky zákazníka za DAIKINem z vystaveného dobropisu
není přípustná, nestanoví-li DAIKIN v konkrétním případě jinak.
VI. DODACÍ LHŮTA
1. Není-li výslovně uvedeno jinak, dodací lhůty uvedené v nabídce jsou pouze orientační a nezávazné, DAIKIN však
usiluje o dodržení uvedených lhůt. Prodlení s dodáním zboží oproti nabídce proto nemají za následek např. nároky na
náhradu škody, resp. újmy, ani neopravňují k odstoupení smlouvy. Totéž platí, jestliže dodací lhůty nebyly dodrženy
v důsledku vyšší moci, stávky nebo jiných událostí, které DAIKIN nemůže ovlivnit.
2. Požadavky zákazníka na smluvní pokuty či jiné penále jsou vyloučeny.
3. Dílčí dodávky DAIKINem zákazníkovi jsou přípustné. Při dílčí (částečné) dodávce nenáleží zákazníkovi náhrada
nákladů částečnou dodávkou způsobených.
4. Je-li zákazník v prodlení s jakoukoliv splatnou platbou vůči DAIKINu, je DAIKIN oprávněn zadržet a pozastavit dodávky zboží zákazníkovi až do okamžiku úhrady všech splatných závazků zákazníka vůči DAIKINu, aniž by byl povinen
nahradit zákazníkovi případně vzniklou újmu. V takovém případě není DAIKIN v prodlení s plněním svého závazku
k dodání zboží.
XI. SOUDNÍ PŘÍSLUŠNOST, ROZHODNÉ PRÁVO
1. Veškeré spory, které vzniknou mezi DAIKINem a zákazníkem budou řešeny obecným soudem s místní příslušností
dle sídla DAIKIN.
2. Veškeré smluvní vztahy jakož i veškeré spory vzniklé v souvislosti s těmito smluvními vztahy se řídí českým právem
s vyloučením jeho kolizních norem. Úmluva OSN o smlouvách o mezinárodní koupi zboží se nepoužije.
3. Práva a povinnosti DAIKINu a zákazníka, která nejsou výslovně upraveny příslušnou smlouvou či těmito Všeobecnými
obchodními podmínkami, se řídí občanským zákoníkem a ostatními právními předpisy v mezích jejich působnosti.
VII. PŘEVZETÍ DODÁVKY, PŘECHOD NEBEZPEČÍ ŠKODY NA ZBOŽÍ, PRODLENÍ S PŘEVZETÍM
1. Dodávky zboží se provádějí, není-li sjednáno něco jiného, podle dodací doložky CIP dle Incoterms 2010 na předem
dohodnuté místo určení.
2. Dodávky zboží podle dodací doložky CIP dle čl. VII odst. 1 těchto Všeobecných obchodních podmínek pokrývají
pouze minimální přepravní náklady. Zvláštní pojištění pro přepravu zboží se uzavírá pouze po zvláštní písemné
dohodě a na náklady zákazníka.
3. Zákazník je povinen zkontrolovat bez zbytečného odkladu zboží, zda nedošlo ke škodám při přepravě a zapsat
případná poškození obalu nebo zboží přímo do přepravního listu a DAIKINu tyto bez zbytečného odkladu, nejpozději
však do následujícího pracovního dne, písemně oznámit. Případné škody vzniklé při přepravě, které nebyly zjevné při
předání zboží, je zákazník povinen reklamovat u DAIKIN okamžitě, nejpozději však do 3 dnů po předání zboží zákazníkovi, v opačném případě nemá zákazník nárok na jakékoliv plnění ze strany DAIKIN. Není- li v konkrétním případě
sjednáno DAIKINem se zákazníkem písemně jinak, pak v případě, že bude doprava (přeprava) zboží realizována na
žádost zákazníka prostřednictvím dopravce zjednaného zákazníkem, podpis dodacího listu zboží přepravcem se pro
účely převzetí zboží a splnění smlouvy ze strany DAIKIN považuje za podpis zákazníka.
4. Zákazník souhlasí, že v případě, že bude zboží DAIKINem přepravováno k zákazníkovi externím přepravcem zjednaným DAIKINem (zejména, ale nikoliv pouze, GEBRÜDER WEISS spol. s r.o.), bude se potvrzení přepravního listu
tohoto přepravce ze strany zákazníka považovat za potvrzení převzetí zboží uvedeného na dodacím listu DAIKINu,
na nějž přepravní list přepravce odkazuje, ze strany zákazníka, když tento dodací list DAIKINu doručí DAIKIN zákazníkovi vždy před dodáním zboží písemně a/nebo faxem a/nebo emailem. Číslo dodacího listu DAIKINu je uvedeno na
přepravních listech přepravce GEBRÜDER WEISS spol. s r.o.
5. Dostane-li se zákazník do prodlení s převzetím zboží, je DAIKIN s výhradou ostatních práv oprávněn se zákazníkem
objednaným zbožím nakládat dle vlastního uvážení (tj. např. prodat jej třetí osobě). V takovém případě počíná doručením písemného požadavku zákazníka na dodávku původně zákazníkem objednaného zboží běžet nová dodací lhůta
v délce sjednané v původní smlouvě.
6. DAIKIN je v případě prodlení zákazníka s převzetím zboží rovněž oprávněn bez dalšího upozornění uskladnit zákazníkem objednané zboží ve svém skladu či na jiném místě na náklady zákazníka.
XII. SALVÁTORSKÁ KLAUZULE
1. V případě neplatnosti nebo neúčinnosti jednotlivých ustanovení těchto Všeobecných obchodních podmínek nebo smlouvy, uzavřené mezi DAIKINem a zákazníkem, zůstává platnost a účinnost zbývajících ustanovení nedotčena. Neplatná
či neúčinná ustanovení budou nahrazena takovými přípustnými ustanoveními, která jsou sjednané vůli stran nejblíže.
XIII. OSTATNÍ
1. Zákazník je oprávněn postoupit jakékoliv pohledávky za DAIKINem na třetí osobu pouze s předchozím písemným
souhlasem DAIKINu.
2. DAIKIN je oprávněn kdykoliv postoupit smlouvu na dodávku zboží se zákazníkem nebo všechna či pouze některá svá
práva a povinnosti z této smlouvy na jiný subjekt, s čímž zákazník uzavřením předmětné smlouvy s DAIKINem souhlasí.
3. Informace poskytnuté DAIKINem zákazníkovi v souvislosti se smlouvou a objednávkami se považují za důvěrné.
4. Zákazník se zavazuje, že neporuší obchodní tajemství DAIKINu, o kterém se dozví v souvislosti s obchodním vztahem. Zároveň se zavazuje, že zajistí dodržování obchodního tajemství DAIKINu i obchodními partnery zákazníka.
5. Veškerá práva DAIKINu plynoucí z uzavřených smluv se promlčují v promlčecí lhůtě v trvání 10 let ode dne, kdy právo
mohlo být uplatněno poprvé.
6. Zákazník na sebe ve smyslu ustanovení § 1765 odst. 2 občanského zákoníku přebírá nebezpečí změny okolností.
7. Tyto Všeobecné obchodní podmínky nabývají platnosti a účinnosti dnem 1. ledna 2014, ruší bez dalšího Všeobecné
obchodní podmínky DAIKIN ze dne 1. 4. 2013, a jejich platnost a účinnost není časově omezená.
DAIKIN AIRCONDITIONING CENTRAL EUROPE – CZECH REPUBLIC spol. s r.o.
Obchodní podmínky společnosti Daikin jsou k dispozici také na internetu na webových stránkách www.daikin.cz.
DAIKIN AIRCONDITIONING CENTRAL EUROPE - CZECH REPUBLIC SPOL. S R. O.
Pobřežní 3, 186 00 Praha 8, Česká republika
Tel.: +420 221 715 700, Fax: +420 221 715 701, Email: [email protected], Web: www.daikin.cz
35
EWAD-TZ
New
inverter and
compressor
technology
The new inverter chiller features a screw compressor with in-built inverter and variable
volume ratio.
These new technologies result in a high seasonal efficiency and a rapid payback
combined with an extensive option list and a compact design.
Daikin Europe N.V. participates in the Eurovent
Certification programme for Air conditioners (AC),
Liquid Chilling Packages (LCP), Air handling units
(AHU) and Fan coil units (FCU), Check ongoing validity
of certificate online: www.eurovent-certification.com
or using: www.certiflash.com
Daikin Products are distributed by:
DAIKIN AIRCONDITIONING CENTRAL EUROPE – CZECH REPUBLIC spol. s r.o.
budova IBC – Pobřežní 3, CZ – 186 00 Praha 8
Tel.: +420 221 715 700, Fax: +420 221 715 701
e-mail: [email protected], www.daikin.cz
DACE Applied Systems Pricelist 2014 • Copyright Daikin
We reserve the right for printing errors and model changes.
The present publication is drawn up by way of information only and does not
constitute an offer binding upon Daikin Europe N.V./Daikin Central Europe
HandelsGmbH. Daikin Europe N.V./Daikin Central Europe HandelsGmbH has
compiled the content of this leaflet to the best of its knowledge. No express
or implied warranty is given for the completeness, accuracy, reliability or fitness
for particular purpose of its content and the products and services presented
therein. Specifications are subject to change without prior notice. Daikin Europe
N.V./Daikin Central Europe HandelsGmbH explicitly rejects any liability for any
direct or indirect damage, in the broadest sense, arising from or related to the
use and/or interpretation of this leaflet. All content is copyrighted by Daikin
Europe N.V.

Podobné dokumenty

Aplikované systémy - Klimatizace Daikin

Aplikované systémy - Klimatizace Daikin interiérových podlah, nízkoemisní tmely a místní nákup materiálů.

Více

Katalog + ceník Aplikované systémy 2016

Katalog + ceník Aplikované systémy 2016 a užívat si trvale udržitelný úspěch spolu s pokračujícím růstem.

Více

Stavové rovnice v teorii regulace

Stavové rovnice v teorii regulace popsán stacionárními operátory. Jinými slovy, systém popsaný diferenciálními rovnicemi s konstantními koeficienty je stacionární a podobně systém vyjádřený rovnicemi (2.19) a (2.20) je stacionární,...

Více

Split, Sky Air - Unifin

Split, Sky Air - Unifin FTXM-M 167 FTXP-KV 168 FDXM-F 169

Více

Split/Sky Air - Klima Chlazení

Split/Sky Air - Klima Chlazení Multi-Split aplikace - komfort pro celý dům z jedné venkovní jednotky Tato jednota může být připojena k multi-splitové venkovní jednotce. Multi-splitové aplikace umožňují chladit několik místností ...

Více

Aplikované systémy - Klimatizace Daikin

Aplikované systémy - Klimatizace Daikin Parapetní / BLDC FWZ-A 2,6 - 10 kW Flexibilní / BLDC FWR-A 2,6 - 10 kW Flexibilní zabudovaná / BLDC FWS-A 2,6 - 10 kW Vzduchotechnické jednotky – AHU D-AHU Modular 1200-15000 m3...

Více

standardní hlučnost

standardní hlučnost a užívat si trvale udržitelný úspěch spolu s pokračujícím růstem.

Více

Ceník - Klimatizace Daikin

Ceník - Klimatizace Daikin  YCQ140DGF obsahuje jemý filtr pro použítí v prostředích s jemným prachem jako například obchody s oblečením. Není vhodný pro prostory s vysokou vlhkostí nebo mastnotou. Bílý (RAL9010) dekorační p...

Více