DWDM_SFP_100Ghz_Mult..
Transkript
DWDM_SFP_100Ghz_Mult..
DWDM SFP Series EOLS-1626-XXD Series SFP Single-Mode for DWDM Application Duplex SFP Transceiver Digital Diagnostic Function RoHS6 Compliant Features Operating Data Rate up to 2.67Gbps Available in all C-Band and L-Band Wavelengths on the 100GHz DWDM ITU Grid Single 3.3V Power Supply and TTL Logic Interface Hot-Pluggable SFP Footprint Duplex LC Connector Interface Compliant with Class 1 FDA and IEC60825-1 Laser Safety Applications Compliant with SFP MSA Amplified DWDM networks Compliant with SFF-8472 Ring topologies with fixed and Operating Case Temperature: reconfigurable OADMs Standard: 0 to 70°C Extended: -5 to 70°C Fast Ethernet, Giga Ethernet Fiber Channel Ordering Information Part No. EOLS-1626-17XX*(note1)D EOLS-1626-17XX *(note1) DI Power budget *(note2) Temp. Up to 2.67Gbps DWDM DFB 17dB Standard Up to 2.67Gbps DWDM DFB 17dB Extended D Up to 2.67Gbps DWDM DFB 29dB Standard *(note1) DI Up to 2.67Gbps DWDM DFB 29dB Extended *(note1) D Up to 2.67Gbps DWDM DFB 33dB Standard *(note1) DI Up to 2.67Gbps DWDM DFB 33dB Extended EOLS-1626-33XX EOLS-1626-33XX Laser *(note1) EOLS-1626-29XX EOLS-1626-29XX Data Rate Note1: XX refers to DWDM Wavelength range as ITU-T specified, please refer the following table for detailed center wavelength information. Note2: The power budget which is guaranteed. Eoptolink Technology Inc., Ltd. Page 1 of 17 V4.c DWDM SFP Series XX- Channel refers to the following table: Channel (XX) Part NO. Frequency (THz) Center Wavelength (nm) 00 EOLS-1626- X*00D EOLS-1626- X*00DI 190.0 1577.86 01 EOLS-1626- X*01D EOLS-1626- X*01DI 190.1 1577.03 02 EOLS-1626- X*02D EOLS-1626- X*02DI 190.2 1576.20 03 EOLS-1626- X*03D EOLS-1626- X*03DI 190.3 1575.37 04 EOLS-1626- X*04D EOLS-1626- X*04DI 190.4 1574.54 05 EOLS-1626- X*05D EOLS-1626- X*05DI 190.5 1573.71 06 EOLS-1626- X*06D EOLS-1626- X*06DI 190.6 1572.89 07 EOLS-1626- X*07D EOLS-1626- X*07DI 190.7 1572.06 08 EOLS-1626- X*08D EOLS-1626- X*08DI 190.8 1571.24 09 EOLS-1626- X*09D EOLS-1626- X*09DI 190.9 1570.42 10 EOLS-1626- X*10D EOLS-1626- X*10DI 191.0 1569.59 11 EOLS-1626- X*11D EOLS-1626- X*11DI 191.1 1568.77 12 EOLS-1626- X*12D EOLS-1626- X*12DI 191.2 1567.95 13 EOLS-1626- X*13D EOLS-1626- X*13DI 191.3 1567.13 14 EOLS-1626- X*14D EOLS-1626- X*14DI 191.4 1566.31 15 EOLS-1606- X15D EOLS-1606- X15DI 191.5 1565.50 16 EOLS-1606- X*16D EOLS-1606- X*16DI 191.6 1564.68 17 EOLS-1606- X*17D EOLS-1606- X*17DI 191.7 1563.86 18 EOLS-1606- X*18D EOLS-1606- X*18DI 191.8 1563.05 19 EOLS-1606- X*19D EOLS-1606- X*19DI 191.9 1562.23 Eoptolink Technology Inc., Ltd. Page 2 of 17 V4.c DWDM SFP Series * 20 EOLS-1606- X 20D EOLS-1606- X*20DI 192.0 1561.42 21 EOLS-1606- X*21D EOLS-1606- X*21DI 192.1 1560.61 22 EOLS-1606- X*22D EOLS-1606- X*22DI 192.2 1559.79 23 EOLS-1606- X*23D EOLS-1606- X*23DI 192.3 1558.98 24 EOLS-1606- X*24D EOLS-1606- X*24DI 192.4 1558.17 25 EOLS-1606- X*25D EOLS-1606- X*25DI 192.5 1557.36 26 EOLS-1606- X*26D EOLS-1606- X*26DI 192.6 1556.55 27 EOLS-1606- X*27D EOLS-1606- X*27DI 192.7 1555.75 28 EOLS-1606- X*28D EOLS-1606- X*28DI 192.8 1554.94 29 EOLS-1606- X*29D EOLS-1606- X*29DI 192.9 1554.13 30 EOLS-1606- X*30D EOLS-1606- X*30DI 193.0 1553.33 31 EOLS-1606- X*31D EOLS-1606- X*31DI 193.1 1552.52 32 EOLS-1606- X*32D EOLS-1606- X*32DI 193.2 1551.72 33 EOLS-1606- X*33D EOLS-1606- X*33DI 193.3 1550.92 34 EOLS-1606- X*34D EOLS-1606- X*34DI 193.4 1550.12 35 EOLS-1606- X*35D EOLS-1606- X*35DI 193.5 1549.32 36 EOLS-1606- X*36D EOLS-1606- X*36DI 193.6 1548.51 37 EOLS-1606- X*37D EOLS-1606- X*37DI 193.7 1547.72 38 EOLS-1606- X*38D EOLS-1606- X*38DI 193.8 1546.92 39 EOLS-1606- X*39D EOLS-1606- X*39DI 193.9 1546.12 40 EOLS-1606- X*40D EOLS-1606- X*40DI 194.0 1545.32 41 EOLS-1606- X*41D 194.1 1544.53 Eoptolink Technology Inc., Ltd. Page 3 of 17 V4.c DWDM SFP Series * EOLS-1606- X 41DI 42 EOLS-1606- X*42D EOLS-1606- X*42DI 194.2 1543.73 43 EOLS-1606- X*43D EOLS-1606- X*43DI 194.3 1542.94 44 EOLS-1606- X*44D EOLS-1606- X*44DI 194.4 1542.14 45 EOLS-1606- X*45D EOLS-1606- X*45DI 194.5 1541.35 46 EOLS-1606- X*46D EOLS-1606- X*46DI 194.6 1540.56 47 EOLS-1606- X*47D EOLS-1606- X*47DI 194.7 1539.77 48 EOLS-1606- X*48D EOLS-1606- X*48DI 194.8 1538.98 49 EOLS-1606- X*49D EOLS-1606- X*49DI 194.9 1538.19 50 EOLS-1606- X*50D EOLS-1606- X*50DI 195.0 1537.40 51 EOLS-1606- X*51D EOLS-1606- X*51DI 195.1 1536.61 52 EOLS-1606- X*52D EOLS-1606- X*52DI 195.2 1535.82 53 EOLS-1606- X*53D EOLS-1606- X*53DI 195.3 1535.04 54 EOLS-1606- X*54D EOLS-1606- X*54DI 195.4 1534.25 55 EOLS-1606- X*55D EOLS-1606- X*55DI 195.5 1533.47 56 EOLS-1606- X*56D EOLS-1606- X*56DI 195.6 1532.68 57 EOLS-1606- X*57D EOLS-1606- X*57DI 195.7 1531.90 58 EOLS-1606- X*58D EOLS-1606- X*58DI 195.8 1531.12 59 EOLS-1606- X*59D EOLS-1606- X*59DI 195.9 1530.33 60 EOLS-1606- X*60D EOLS-1606- X*60DI 196.0 1529.55 61 EOLS-1606- X*61D EOLS-1606- X*61DI 196.1 1528.77 62 EOLS-1626- X*62D EOLS-1626- X*62DI 186.2 1610.06 Eoptolink Technology Inc., Ltd. Page 4 of 17 V4.c DWDM SFP Series 63 EOLS-1626- X*63D EOLS-1626- X*63DI 186.3 1609.19 64 EOLS-1626- X*64D EOLS-1626- X*64DI 186.4 1608.33 65 EOLS-1626- X*65D EOLS-1626- X*65DI 186.5 1607.47 66 EOLS-1626- X*66D EOLS-1626- X*66DI 186.6 1606.60 67 EOLS-1626- X*67D EOLS-1626- X*67DI 186.7 1605.74 68 EOLS-1626- X*68D EOLS-1626- X*68DI 186.8 1604.88 69 EOLS-1626- X*69D EOLS-1626- X*69DI 186.9 1604.03 70 EOLS-1626- X*70D EOLS-1626- X*70DI 187.0 1603.17 71 EOLS-1626- X*71D EOLS-1626- X*71DI 187.1 1602.31 72 EOLS-1626- X*72D EOLS-1626- X*72DI 187.2 1601.46 73 EOLS-1626- X*73D EOLS-1626- X*73DI 187.3 1600.60 74 EOLS-1626- X*74D EOLS-1626- X*74DI 187.4 1599.75 75 EOLS-1626- X*75D EOLS-1626- X*75DI 187.5 1598.89 76 EOLS-1626- X*76D EOLS-1626- X*76DI 187.6 1598.04 77 EOLS-1626- X*77D EOLS-1626- X*77DI 187.7 1597.19 78 EOLS-1626- X*78D EOLS-1626- X*78DI 187.8 1596.34 79 EOLS-1626- X*79D EOLS-1626- X*79DI 187.9 1595.49 80 EOLS-1626- X*80D EOLS-1626- X*80DI 188.0 1594.64 81 EOLS-1626- X*81D EOLS-1626- X*81DI 188.1 1593.79 82 EOLS-1626- X*82D EOLS-1626- X*82DI 188.2 1592.95 83 EOLS-1626- X*83D EOLS-1626- X*83DI 188.3 1592.10 Eoptolink Technology Inc., Ltd. Page 5 of 17 V4.c DWDM SFP Series 84 EOLS-1626- X*84D EOLS-1626- X*84DI 188.4 1591.26 85 EOLS-1626- X*85D EOLS-1626- X*85DI 188.5 1590.41 86 EOLS-1626- X*86D EOLS-1626- X*86DI 188.6 1589.57 87 EOLS-1626- X*87D EOLS-1626- X*87DI 188.7 1588.73 88 EOLS-1626- X*88D EOLS-1626- X*88DI 188.8 1587.88 89 EOLS-1626- X*89D EOLS-1626- X*89DI 188.9 1587.04 90 EOLS-1626- X*90D EOLS-1626- X*90DI 189.0 1586.20 91 EOLS-1626- X*891D EOLS-1626- X*91DI 189.1 1585.36 92 EOLS-1626- X*92D EOLS-1626- X*92DI 189.2 1584.53 93 EOLS-1626- X*93D EOLS-1626- X*93DI 189.3 1583.69 94 EOLS-1626- X*94D EOLS-1626- X*94DI 189.4 1582.85 95 EOLS-1626- X*95D EOLS-1626- X*95DI 189.5 1582.02 96 EOLS-1626- X*96D EOLS-1626- X*96DI 189.6 1581.18 97 EOLS-1626- X*97D EOLS-1626- X*97DI 189.7 1580.35 98 EOLS-1626- X*98D EOLS-1626- X*98DI 189.8 1579.52 99 EOLS-1626- X*99D EOLS-1626- X*99DI 189.9 1578.69 *: X refers to the DWDM Power budget (17 29 33). Please contact EOPTOLINK to confirm whether the wavelength is available. Eoptolink Technology Inc., Ltd. Page 6 of 17 V4.c DWDM SFP Series Regulatory Compliance Product Certificate Certificate Number Applicable Standard EN 60950-1:2006+A11+A1+A12 TUV R50135086 EN 60825-1:2007 EN 60825-2:2004+A1+A2 UL E317337 EMC CE AE 50135430 0001 CB JPTUV-024038-M1 UL 60950-1 CSA C22.2 No. 60950-1-07 EN 55022:2006 EN 55024:1998+A1+A2 IEC 60825-2 IEC 60950-1 WTF13F0503735E 47 CFR PART 15 OCT., 2010 WTF13F0503732E 47 CFR PART 15 OCT., 2010 FDA 1230816-000 CDRH 1040.10 ROHS RLSZF00163462 2011/65/EU FCC Product Description The EOLS-1626-XXD series single mode transceiver is small form factor pluggable module for duplex optical data communications. This module is designed for single mode fiber and operates at a nominal DWDM wavelength from 1528.77nm to 1565.50nm (C band) and 1578.69nm to 1610.06nm (L band) as specified by the ITU-T. It is designed to deploy in the DWDM networking equipment in metropolitan access and core networks. And they are designed to be compliant with SFF-8472 Multi-Source Agreement (MSA). It is with the SFP 20-pin connector to allow hot plug capability. The transmitter section uses a DWDM multiple quantum well DFB laser and is a class 1 laser compliant according to International Safety Standard IEC-60825. Absolute Maximum Ratings*Note3 Parameter Symbol Min. Max. Unit Storage Temperature TS -40 +85 °C Supply Voltage VCC -0.5 3.6 V - 95 % Operating Relative Humidity *Note3: Exceeding any one of these values may destroy the device permanently. Recommended Operating Conditions Parameter Operating Case Temperature Symbol TC Min. Typical Max. EOLS-1626-XXD 0 - +70 EOLS-1626-XXDI -5 - +70 Unit °C Power Supply Voltage VCC 3.15 3.3 3.45 V Power Supply Current ICC - - 450 mA Power dissipation PW 1.5 W Eoptolink Technology Inc., Ltd. Page 7 of 17 V4.c DWDM SFP Series OC-48/STM-16 FEC Date Rate 2.67 OC-48/STM-16 - 2.488 - 2FC - 2.125 - GBE - 1.25 - FC - 1.063 - OC-12/STM-4 - 622 - OC-3/STM-1 - 155 - FE - 100 - Gbps Mbps Performance Specifications - Electrical Parameter Symbol CML Inputs(Differential) Vin 400 Input Impedance (Differential) Zin 85 TX_Dis TX_FAULT Min. Typ. Transmitter 100 Max Unit Notes 1600 mVpp AC coupled inputs 115 ohm Disable 2 Vcc Enable 0 0.8 Fault 2 Vcc Normal 0 0.8 Rin > 100 kohm @ DC V V Receiver CML Outputs (Differential) Vout 400 800 1200 mVpp Output Impedance (Differential) Zout 85 100 115 ohm 2 Vcc V 0 0.8 V RX_LOS LOS Normal MOD_DEF ( 0:2 ) VoH 2.5 VoL 0 AC coupled outputs V 0.8 V Performance Specifications – Optical (DWDM DFB and PIN/TIA, 17dB Power Budget at Least) Parameter Symbol Min. Data Rate Typical Max. 2.5 Unit Gbps Transmitter Center Wavelength λ Spectral Width (-20dB) ∆λ Side Mode Suppression Ratio SMSR Channel Spacing ∆f Deviation From Central Frequency@EOL Side Mode Suppression Ratio 1528 Eoptolink Technology Inc., Ltd. Page 8 of 17 nm 0.3 nm 30 dB 100 -12 SMSR 1610 30 GHz 12 GHz dB V4.c DWDM SFP Series (Note4) Average Output Power* Pout Average Launch Power (Tx: OFF) Poff (Note4) Extinction Ratio* 0 ER ~ (Note4) dBm -45 dBm 8.2 dB tr/tf Rise/Fall Time(20% 80%) 5 150 ps (Note7) Output Optical Eye* Compatible with IEEE 802.3* TX_Disable Assert Time Pout@TX Disable Asserted (Note9) Optical Signal Noise [email protected]* t_off 10 us Pout -45 dBm -135 dB/Hz OSNR Relative Intensity Noise RIN Dispersion Tolerance DT 40 dB 1120 ps/nm Receiver Center Wavelength Receiver Sensitivity*(Note6) 1528 λ Multirate*(Note5) Pmin Receiver Overload Pmax LOS De-Assert LOSD LOS Assert LOSA 1620 nm -17 dBm -3 dBm -19 (Note8) LOS Hysteresis* dBm -31 dBm 0.5 dB (DWDM DFB and APD, 29dB Power Budget at Least) Parameter Symbol Min. Data Rate Typical Max. Unit 2.5 Gbps Transmitter Center Wavelength λ 1528 Spectral Width (-20dB) ∆λ Side Mode Suppression Ratio SMSR Channel Spacing ∆f Average Output Power* Pout Average Launch Power (Tx: OFF) Extinction Ratio* ER ~ (Note4) nm dB GHz -12 12 GHz 0 5 dBm -45 dBm 8.2 dB tr/tf Rise/Fall Time(20% 80%) 0.3 30 Poff (Note4) nm 100 Deviation From Central Frequency@EOL (Note4) 1610 150 ps (Note7) Output Optical Eye* Compatible with IEEE 802.3* TX_Disable Assert Time t_off Pout Pout@TX Disable Asserted (Note9) Optical Signal Noise [email protected]* OSNR Relative Intensity Noise RIN Dispersion Tolerance DT 10 us -45 dBm 40 dB -135 2080 dB/Hz ps/nm Receiver Center Wavelength Receiver Sensitivity*(Note6) Multirate*(Note5) λ 1528 Pmin Receiver Overload Pmax LOS De-Assert LOSD LOS Assert LOSA Eoptolink Technology Inc., Ltd. Page 9 of 17 1620 nm -29 dBm -9 dBm -31 -43 dBm dBm V4.c DWDM SFP Series (Note8) LOS Hysteresis* 0.5 dB (DWDM DFB and APD, 33dB Power Budget at Least) Parameter Symbol Min. Data Rate Typical Max. Unit 2.5 Gbps Transmitter Center Wavelength λ Spectral Width (-20dB) ∆λ 1528 Side Mode Suppression Ratio SMSR Channel Spacing ∆f SMSR 30 Pout 2 Average Launch Power (Tx: OFF) Poff ER ~ GHz 12 GHz 5 dBm -45 dBm dB 8.2 dB tr/tf Output Optical Eye*(Note4) 150 ps Compatible with IEEE 802.3*(Note7) TX_Disable Assert Time Pout@TX Disable Asserted Optical Signal Noise [email protected]* dB -12 Average Output Power*(Note4) Rise/Fall Time(20% 80%) nm 30 Side Mode Suppression Ratio Extinction Ratio* nm 0.3 100 Deviation From Central Frequency@EOL (Note4) 1610 (Note9) t_off 10 us Pout -45 dBm OSNR Relative Intensity Noise RIN Dispersion Tolerance DT 40 dB -135 2400 dB/Hz ps/nm Receiver Center Wavelength (Note6) λ (Note5) Receiver Sensitivity* Multirate* 1528 Pmin Receiver Overload Pmax LOS De-Assert LOSD LOS Assert LOSA (Note8) LOS Hysteresis* 1620 nm -31 dBm -9 dBm -32 dBm -44 dBm 0.5 dB 23 Note4: Filtered, measured with a PRBS 2 -1 test pattern @2.5Gbps. Note5: OC-48/2X FC/1X FC/OC-12/OC-03. 23 -12 Note6: Measured with a PRBS 2 -1 tests pattern @2.5Gbps, G.652 SMF, BER ≤1×10 . Note7: Eye Pattern Mask Note8: LOS Hysteresis Note9: OSNR at a BER of 10e-12 Eoptolink Technology Inc., Ltd. Page 10 of 17 V4.c DWDM SFP Series Functional Description of Transceiver SFP Transceiver Electrical Pad Layout Eoptolink Technology Inc., Ltd. Page 11 of 17 V4.c DWDM SFP Series Pin Function Definitions Pin Num. Name Function Description 1 VeeT Transmitter Ground 2 TX Fault 3 TX Disable Transmitter Disable Transmitter Fault Indication, open collector/drain output 4 MOD-DEF2 Module Definition 2, Data line for Serial ID. 5 MOD-DEF1 Module Definition 1, Clock line for Serial ID. 6 MOD-DEF0 Module Definition 0, Grounded within the module. 7 Rate Select Not Connect, Function not available 8 LOS Loss of Signal, open collector/drain output 9 VeeR Receiver Ground 10 VeeR Receiver Ground 11 VeeR Receiver Ground 12 RD- Inv. Received Data Out 13 RD+ Received Data Out 14 VeeR Receiver Ground 15 VccR Receiver Power, 3.3 ± 5% 16 VccT Transmitter Power, 3.3 ± 5% 17 VeeT Transmitter Ground 18 TD+ Transmit Data In 19 TD- Inv. Transmit Data In 20 VeeT Transmitter Ground EEPROM The serial interface uses the 2-wire serial CMOS EEPROM protocol defined for the ATMEL AT24C02/04 family of components. When the serial protocol is activated, the host generates the serial clock signal (SCL). The positive edge clocks data into those segments of the EEPROM that are not write protected within the SFP transceiver. The negative edge clocks data from the SFP transceiver. The serial data signal (SDA) is bi-directional for serial data transfer. The host uses SDA in conjunction with SCL to mark the start and end of serial protocol activation. The memories are organized as a series of 8-bit data words that can be addressed individually or sequentially. The Module provides diagnostic information about the present operating conditions. The transceiver generates this diagnostic data by digitization of internal analog signals. Calibration and alarm/warning threshold data is written during device manufacture. Received power monitoring, transmitted power monitoring, bias current monitoring, supply voltage monitoring and temperature monitoring all are implemented. If the module is defined as external calibrated, the diagnostic data are raw A/D values and must be converted to real world units using calibration constants stored in EEPROM locations 56 – 95 at wire serial bus address A2H. The digital diagnostic memory map specific data field define as following .For detail EEPROM information, please refer to the related document of SFF 8472 Rev 9.3. Eoptolink Technology Inc., Ltd. Page 12 of 17 V4.c DWDM SFP Series EEPROM Serial ID Memory Contents Accessing Serial ID Memory uses the 2 wire address 1010000X(A0H). Memory Contents of Serial ID are shown in Table 1. Table 1 Serial ID Memory Contents Addr. Size (bytes) Name of field Vaule(Hex) 0 1 Identifier 0B 1 1 Ext. Identifier XX 2 1 Connector 07 LC connector 00 Reserved 00 - 00 - 3-10 8 Transceiver Codes Description DWDM SFP XX XX XX 01 Single mode XX 11 1 Encoding XX 12 1 BR, Nominal 13 1 Reserved 00 14 1 Length (9µm)km XX XX(Note10) Eoptolink Technology Inc., Ltd. Page 13 of 17 - V4.c DWDM SFP Series 15 1 Length(9µm)100m FF 16 1 Length (50µm) 10m 00 17 1 Length(62.5µm)10 m 00 18 1 Length (Copper) 00 19 1 Reserved 00 Not compliant 20~3 5 16 Vendor Name XX XX XX XX XX XX XX XX XX XX XX XX XX XX XX XX(Note10) 36 1 Implemented Optional DWDM Features 00 - 37-39 3 Vendor OUI 00 00 00 - 40-55 16 Vendor PN XX XX XX XX XX XX XX XX XX XX XX XX XX XX XX XX(Note10) 56-59 4 Vendor Rev XX XX XX XX(Note10) 60-62 3 Wavelength XX 63 1 CC-BASE XX Vendor name PN Laser Wavelength CC for Base ID fields implemented (addresses 0 to62) 00 Reserved 1A 1.TX_DISABLE is implemented and disables the serial output; 2.TX_FAULT signal implemented; 3.Loss of Signal implemented 64~6 5 2 Options 66 1 BR, max 00 - 67 1 BR, max 00 - 68~8 3 16 Vendor SN XX Serial number of Transceiver (ASCII) 84~8 9 6 Date code XX The vendor’s date code (ASCII) 90~9 1 2 Vendor specific lot code XX XX 92 1 Diagnostic Monitoring Type XX Eoptolink Technology Inc., Ltd. Page 14 of 17 1. Digital diagnostic monitoring implemented 2.Internally/Externally Calibrated; 3.Received power measurement type is V4.c DWDM SFP Series Average Power 93 94 1 Enhanced Options 1 SFF-8472 Compliance F0 1.Optional Alarm/warning flags implemented for all monitored quantities 2. Optional Soft TX_DISABLE control and monitoring implemented 3. Optional Soft TX_FAULT monitoring Implemented 4. Optional Soft RX_LOS monitoring Implemented 01 Includes functionality described in Rev 9.3 of SFF-8472. 95 1 CC_EXT XX CC for the extended ID Fields (addresses 64 to 94) implemented. 96~1 27 32 Vendor Specific XX Read only memory 128-2 55 128 Reserved Read only Note10: The “XX” byte should be filled in according to practical case. For more information, please refer to the related document of SFP Multi-Source Agreement (MSA). Recommend Circuit Schematic Eoptolink Technology Inc., Ltd. Page 15 of 17 V4.c DWDM SFP Series Mechanical Specifications Obtaining Document You can visit our website: http://www.eoptolink.com Or contact Eoptolink Technology Inc., Ltd. Listed at the end of the documentation to get the latest documents. Revision History Revision Initiated Reviewed Approved Kelly.Cao Revision History Release Date Released. Oct 24, 2009 V2.a Tim.Liang V2.b Kelly Revise the A2H. Nov 24, 2009 V2.c Kelly Complete the DWDM wavelength. Jan 18, 2010 V2.d Kelly Correct Rx λ range. Apr 8, 2010 V3.a Kelly Update PN&LOGO. July 19, 2011 V3.b Jans Kelly Update EEPROM map, integrate 3 products. Sep 21, 2011 V3.c Jans Kelly Add 34Db products. Dec 16, 2011 V3.d Jans Delete the product of 34Db budget. Jan 6,2012 V3.e Jans Add OSNR/DNP. Feb 27,2012 V3.f Jans Kelly Update the Eoptolink Technology Inc., Ltd. Page 16 of 17 May 15 ,2012 V4.c DWDM SFP Series Los-Assert of 29dB budget. V3.g Kelly Update note. V3.h Abby Jason, Kelly V4.a Jans Jason, Nygai Update ICC and PW Phlio Oct 10, 2012 Dec 13, 2012 Add L band. Mar 5, 2013 Sep 25,2013 October 17, 2013 V4.b Angela Lyn/Jason/ Walt/Nygai Update regulatory compliance, Tr/Tf and the Pout of 17dB and 33dB products. V4.c Angela Kelly/Jason Correct the Max receiver wavelength. Notice: Eoptolink reserves the right to make changes to or discontinue any optical link product or service identified in this publication, without notice, in order to improve design and/or performance. Applications that are described herein for any of the optical link products are for illustrative purposes only. Eoptolink makes no representation or warranty that such applications will be suitable for the specified use without further testing or modification. Contact: Add: Floor 5, Building 2, No. 21 Gaopeng Avenue, High-Tech District, CHENGDU, SICHUAN 610041 P.R. CHINA Tel: (+86) 028-85122709 ext 816 & 809 Fax: (+86) 028-85121912 Postal: 610041 E-mail:[email protected] http://www.eoptolink.com Eoptolink Technology Inc., Ltd. Page 17 of 17 V4.c