VRT-200 ING R3
Transkript
VRT-200 ING R3
TECSYSTEM S.r.l ® INSTRUCTION MANUAL VRT-200 TECSYSTEM S.r.l. Via Cristoforo Colombo, 5/C 20094 Corsico (MI) phone +39 - 02 - 48601011 / 4581861 Fax: +39 - 02 – 48600783 http://www.tecsystem.it R.3 27/03/03 VRT200 protection relays TECSYSTEM S.r.l ® 1) TECHNICAL SPECIFICATIONS AUXILIARY POWER SUPPLY • • Rated voltage-VRT power 230 Vac ±10% (5VA max) 50-60 Hz Rated voltage-fan power 230 Vac±10% (10 A max) 50-60 Hz INPUTS OUTPUTS • • • 1 contact for remote control enable (ENABLE) Removable rear terminals • 1 alarm and fault relay (ALARM/ FAULT) Output contact capacity 5A-250 Vac res. TESTS AND PERFORMANCES DISPLAYING AND DATA MANAGEMENT • • • • • • • • • • • Assembling in accordance with CE rules protection against electrical and magnetic noises CEI-EN500812/50082-2 Dielectric strength 2500 Vac for 1 minute Ambient operating temperature -20° C to + 60°C humidity 90% no-condensing ABS self-extinguishing housing NORYL 94VO Opt. Frontal plastic protection Opt. Protection treatment of electronic part Frontal in polycarbonate IP54 burden 5VA (max) • • • • • • Led indicating the correct working of the motors (In) Led indicating REMOTE or LOCAL fan control Led indicating max/min current alarm (>In, <In) Start-up AUTO-TUNING for motors setting Frontal motors local START/STOP push button Frontal alarm RESET push button Entering the programming cycle by front push button DIMENSIONS • • 2 96x96mm DIN43700 depth 160mm (with rear terminals) Panel cut-out 92x92mm VRT200 protection relays TECSYSTEM S.r.l ® 2) AUXILIARY POWER SUPPLY The VRT200 has 2 power supply inputs: the first gives power supply only to the unit and it has a small capacity (5VA max.), the second gives power supply to the fan motors, therefore it has to be connected with the appropriate power supply. The lack of the first power supply input excludes every functioning both of the unit and of the fans, even if we have voltage on the second input. 3) FUNCTIONING When the unit turns on it makes a LAMP TEST and it goes in REMOTE mode. In this way the fans are activated by the remote input contacts closure. • HOW TO START THE FANS BY THE PANEL To start the motors in local mode push the button LOCAL/REMOTE in order to set up the LOCAL mode (led LOCAL ON and led REMOTE OFF); push now the button “START/ STOP” in order to activate or disactivate the motors. At the end of these phases in LOCAL mode, push again the button LOCAL/REMOTE in order to make the unit works in normal conditions (REMOTE mode) • HOW TO START THE FANS BY REMOTE Fans are activated when ENABLE input is driven by FAN contact (10-11) of the unit T154. • Push the button L.T. in order to make the LAMP TEST. • HOW TO MAKE A REGENERATION OF A MOTOR IN TRIP To restart a turned off motor after an over/under current alarm, press RESET push button after having carried out the due inspection and possible repairs. • HOW TO CHECK THE MOTORS − − − NOTE: Led In on: correct working of the motor Led >In on: motor alarm and stop for max. current Led <In on: motor alarm and stop for min. current The alarm conditions of a motor or the lack of auxiliary power supply in the meter cause the closing of contacts 8-9 of ALARM/FAULT relay VRT200 protection relays 3 TECSYSTEM S.r.l ® 4) PROGRAMMING STEP 1 PUSH BUTTON RESULT Programming Start NOTES The led showing the highest admitted absorbed current variation (±%) is flashing. 2 Choice of the data item to be programmed Load the highest admitted current variation as percentage value (5%, 10%) with respect to the rated value In. 3 Confirmation of chosen data item % led is fixed while CAL led is flashing. 4 Motors start for automatic calibration To execute the automatic calibration, all the motors have to be connected with a definitive configuration. START: motors are ON for 90 seconds, CAL led is fixed while STATUS section leds are flashing. When the calibration is over, the motors turn off and CAL led is flashing again. 5 4 Exit and programming confirmation The unit gets ready to work in REMOTE mode. VRT200 protection relays TECSYSTEM S.r.l ® 5) FRONT PANEL VRT200 protection relays 5 TECSYSTEM S.r.l ® 6) WARRANTY The series “VRT” units are under warranty for 12 months from the delivery date signed on the unit. The warranty is recognised when the unit breaks down due to some causes chargeable to TECSYSTEM srl such as production faults or insufficient calibration. The warranty is not valid if the unit has been tampered or when it has been damaged by a wrong voltage supply beyond the highest working limits (220Vac). The warranty is not valid if the unit should be burnt out by too high transient voltage peaks. In this case TECSYSTEM srl is not answerable for damages caused by faulted or defective units. All the delivery expenses (there and back) of the unit must be paid by the Customer. In case of dispute, the qualified FORUM is the one of Milan. Warranty is always EXW our company in Corsico (incomterms 2000). 6 VRT200 protection relays TECSYSTEM S.r.l ® 7) FAN MOTOR CONNECTION Motors must be DIRECTLY connected to VRT200, since it gives PHASE and NEUTRAL to each motor. TECSYSTEM srl Tel. 02/48601011 Fax. 02/48600783 Mod.VRT200 43 OUTPUT FAN 2 X 5A MAX Output for fan auxiliary power supply 44 45 46 LINE FAN 230Vac +/-10% 50Hz 10A max 230Vac +/-10% 50Hz 5VA 40 41 42 LINE Unit auxiliary power supply Input for fan auxiliary power supply 40 42 FAULT 7 8 9 ALARM Alarm relay 52 53 ENABLE Remote control VRT200 protection relays 7 TECSYSTEM S.r.l ® VRT200 TEST DESCRIPTION The unit was submitted to the following tests during production: N° Description 1 PC board test 2 Input test 3 Test of relay contacts and outputs 4 Key test 5 Lamp test 6 Calibration at 100 and 200°C (for temperature monitoring units) 7 Software test 8 Burn-in minimum 24h Date of shipment: 8 VRT200 protection relays