Návod spínací hodiny Ateso Alfa Breeze IV a

Transkript

Návod spínací hodiny Ateso Alfa Breeze IV a
Návod k obsluze nezávislého horkovzdušného topení
Operating instruction for an air heater
Producer:
BRANO a.s.,
SBU CV
NA Račanech 100
514 01 Jilemnice
Czech Republic
03-9940.185
V2 25.3.2015
Obsah / Contents:
Návod k obsluze nezávislého horkovzdušného topení
s ručním ovládáním ALFA………………………………………………………………...2
Návod k obsluze nezávislého horkovzdušného topení
se spínacími hodinami ALFA……………………………………………………………..5
Návod k obsluze nezávislého horkovzdušného topení
s ovládáním Basic ALFA…………………………………………………………………13
Operating instruction for an air heater
with the manual control ALFA….….…………………………………………………….15
Operating instruction for an air heater
with the timer ALFA……..………………………………………………………………..19
Operating instruction for an air heater
with the control Basic ALFA……….…………………………………………………….26
Záruční list / Warranty certificate……….……………………………………………….28
Vážený zákazníku,
Blahopřejeme Vám k zakoupení nezávislého horkovzdušného topení BREEZE IV, WIND IV, ATESO ALFA.
Jedná se o moderní a úsporné zařízení určené k vytápění prostoru kabin motorových, skříňových nástaveb,
kabin pracovních strojů, obytných přívěsů, stacionárních buněk, jachet apod. a to buď v recirkulačním
provozu, nebo s možností nasávání vzduchu z venkovního prostoru.
Věříme, že Vám naše topení zpříjemní chvíle strávené v zaměstnání či na dlouhých cestách.
Před začátkem manipulace si nejdříve přečte návod k obsluze!!!
POZOR!!!
V prostoru čerpací stanice nebo skladu paliva musí být topení vypnuto z důvodu nebezpečí výbuchu.
Rovněž tak v prostorách v niž se tvoří hořlavé páry nebo prach (např. paliva, dřevěný, uhelný nebo
obilný prach apod.) musí být topení z důvodu nebezpečí výbuchu vypnuto.
Topení nesmí být provozováno v uzavřených a nevětraných prostorách z důvodu nebezpečí otravy či
udušení
Dear customer,
We congratulate you on your purchase of the air heater BREEZE IV, WIND IV, ATESO ALFA.
It is modern and economical device to heat the space of car cabin, truck bodies, working machine cabins,
caravans, stationary units, yachts, etc. in the regime of recirculated air or with the possibility to ventilate air
from the surrounding area.
We believe that the heater will make time you spend by traveling or working really good.
First read these instructions carefully before operating the heater!!!
ATENTION!!!
In area of filing station or fuel depot the heater must be off to prevent the danger of explosion. Also in
areas where combustion fumes or dust (fuel, coal, wood or corn dust, etc.) generate, the heat must be
off due to the danger of explosion.
The heater must not be in operation nor be turned on by pre-selection in closed and unventilated areas
due to the danger of intoxication or suffocation.
1
03-9940.185
RUČNÍ OVLÁDÁNÍ ALFA
Ovladač nezávislého topení BREEZE IV - WIND IV - ATESO
Obsah balení:
Ovladač
Kabel
Suchý zip
Plastový klip
Vrut k připevnění klipu
1 ks
2 ks
2 ks
1 ks
1 ks
1. FUNKCE
Ruční ovládání (dále jen RO) nezávislého horkovzdušného topení BREEZE IV, WIND IV a ATESO ALFA
umožňuje zapínání / vypínání topení a ventilace. V režimu topení je možné otočným potenciometrem měnit
plynule výkon topení nebo požadovanou teplotu a v režimu větrání měnit otáčky ventilátoru.
Topení je schopno pracovat v těchto režimech:
- Topení na výkon
- Topení na teplotu
- Větrání
- Vypálení spalovací komory
- Čerpání paliva
- MENU pro nastavení režimů a některých vlastností topení
Potenciometr
nastavení
výkonu/teploty,
výběr MENU
Žlutá dioda – indikace:
- časovače
- větrání / dovětrávání,
-výběr MENU
-vypálení
Tlačítko zapnutí / vypnutí
topení,
Odvětrání spalovací komory,
Potvrzení MENU
Zelená barva – indikace:
-startu a provozu topení
-výběr MENU
-odvětrání
Tlačítko zapnutí /
vypnutí větrání,
Odstavení časovače,
Opuštění MENU
Červená dioda –
indikace:
-chyby
-omezování výkonu
-výběr MENU
2. SIGNALIZACE A OVLÁDÁNÍ
2.1. SIGNALIZAČNÍ DIODY
Činnost nezávislého topení je signalizována na panelu třemi LED-diodami.
Start topení/ Regulační otáčky - bliká dolní zelená dioda
Topení - trvale svítí dolní zelená dioda
Dovětrávání- bliká horní žlutá dioda
2
03-9940.185
Větrání - trvale svítí horní žlutá dioda
Časovač - trvale svítí horní žlutá dioda při topení
Porucha – bliká střední červená dioda, počet bliknutí mezi mezerou určuje příčinu chyby
viz tabulka - bod 9. Chybová hlášení
Vypálení spalovací komory – bliká současně žlutá a zelená dioda
Omezení výkonu při přehřátí – trvale svítí střední červená diod
2.2 OVLÁDACÍ PRVKY
- zapínání a vypínání větrání, odstavení poruchy, odstavení časovače (dlouhý stisk), opuštění
MENU
- zapínání a vypínání topení, vypálení spalovací komory (dlouhý stisk), potvrzení MENU
POTENCIOMETR NASTAVENÍ
- Potenciometrem nastavení lze nastavit žádaný výkon nebo teplotu na jakou má topení
pracovat (1 – 30°C). V režimu MENU se potenciometrem vybírají jednotlivé volby.
2.3 OVLÁDACÍ KONEKTORY
Komunikační konektor (3pin) - slouží k připojení topení. Při použití rozdvojky na LIN-sběrnici lze připojit
externí čidlo teploty a „další příslušenství“.
Konektor klíčku a podsvícení (2pin zásuvka) - umožnuje trvalé odstavení časovače při chodu motoru a trvalé
podsvícení při zapnutí světel. Pohled do konektoru - pojistka nahoře - levý pin
podsvícení/pravý časovač.
Konektor externího zapnutí (2pin zástrčka) – umožnuje připojení tlačítka, kterým lze zapnout a vypnout
topení, přičemž parametry topení se přebírají z nastavení RO (pulzní
ovládání).
2.4 ZVUKOVÁ SIGNALIZACE
Pípá při stisku tlačítka a chybě.
3. TOPENÍ
3.1 ZAPNUTÍ TOPENÍ
Je-li topení v klidu, pak se spouští tlačítkem
.Činnost topení je indikována zelenou diodou, pokud bliká je
topení v režimu start nebo v regulačním větrání (při provozu v režimu regulace „na teplotu” ).
3.2 TOPENÍ NA VÝKON
Topení v režimu na výkon sleduje nastavení potenciometru. Při startu topení (bliká zelená kontrolka), po
úspěšném zapálení, je chod topení automaticky nastaven na plný výkon a není jej možné regulovat. Až po
trvalém rozsvícení zelené diody je možné výkon regulovat na požadovaný pootočením potenciometru.
3.3 TOPENÍ NA TEPLOTU
Při startu topení v režimu Na teplotu zahájí topení činnost pouze tehdy, pokud požadovaná (nastavená)
teplota na potenciometru je vyšší než teplota navoleného čidla teploty, jinak zůstane ve stavu Odvalování
(bliká zelená dioda) tzn., že se ventilátor mírně točí a vyhodnocuje se teplota navoleného čidla teploty. Při
vyšší požadované teplotě dojde k zapnutí topení. Po trvalém rozsvícení zelené diody (úspěšném startu) se
výkon topení postupně přizpůsobí nastavené teplotě na potenciometru. Dosáhne-li skutečná teplota teplotu
požadovanou, dojde k automatickému snižování výkonu topení a přesáhne-li tuto teplotu, dojde k vypnutí
hoření a přechodu na regulační otáčky. Po poklesu skutečné teploty pod nastavenou hodnotu se topení opět
automaticky spustí a začne topit (je signalizováno zelenou, stále svítící diodou). Navolit v MENU je možné tyto
čidla teploty: T1-teplota nasávaného vzduchu topením, T2-teploměr v SH, T3-externí čidlo teploty
3
03-9940.185
Topení v režimu na teplotu má většinou díky častějším startům vyšší nároky na elektrický příkon, což má za
následek zkrácení doby provozu na baterii.
3.4 VYPNUTÍ TOPENÍ
Topení se vypíná stiskem tlačítkem
, topení přejde do režimu dovětrání (bliká horní žlutá dioda). Po
dovětrání přejde topení do klidu, kdy nesvítí žádná dioda.
4. VĚTRÁNÍ
Je-li topení v klidu, pak se Větrání spouští tlačítkem
a je indikováno trvalým svitem žluté diody.
Intenzitu větrání lze nastavit potenciometrem.
Pokud žlutá dioda bliká, jedná se o stav dovětrávání
Stiskem tlačítka
přejde topení do klidu a zároveň zhasne žlutá dioda.
5. VYPÁLENÍ SPALOVACÍ KOMORY
Tento stav se spouští delším stiskem tlačítka
v klidu a je signalizován blikáním žluté a zelené LED.
Používá se po neúspěšném startu k pokusu o nastartování topení kdy topení žhaví a mírně větrá bez
dodávky nafty. V případě, že dojde k úspěšnému zapálení, následuje hoření podle nastavení RO. Vypnutí
a je omezen časem.
se provádí opětovným stiskem tlačítka
6. ČERPÁNÍ PALIVA
Používá se při potřebě zaplnění palivového potrubí palivem a její volba a nastavení je popsáno v MENU – viz
bod 8.
7. ČASOVAČ
Časovač způsobuje časové omezení chodu topení, když není zapnutý klíček zapalování automobilu. Tato
hodnota je nastavena na 30 min a nelze ji měnit. Po uplynutí této doby se topení automaticky vypne.
Zapnutím klíčku v zapalování je omezení hoření časovačem zrušeno a chod topení je neomezený. Režim
časovače je indikován stálým svitem žluté diody. Časovač lze odstavit zapnutím klíčku zapalování nebo také
na dobu cca 2 sec. - žlutá dioda zhasne. Jestliže topení topí, tak se vypnutím klíčku
přidržením tlačítka
zapalování vždy aktivuje časovač.
Režim Větrání je omezen časovačem na 6 hod. a nejde odstavit.
8. MENU
Přechod do MENU: Stisknout a držet tlačítko
, když blikne zelená LED, tak současně stisknout tlačítko
.
Začne blikat zelená nebo žlutá LED podle nastaveného režimu topení - mezera 1x blik.
Ovládání MENU: Potvrzení a přechod do dalšího kroku MENU - tlačítko
Výběr možností MENU pomocí natáčení potenciometru
Opuštění MENU - tlačítko
Po cca 50 sec. nečinnosti přejde do provozního stavu.
Funkce MENU: 1. Mezera 1x blik - Přepnutí : Topení na výkon (zelená LED)
Topení na teplotu (žlutá LED)
2. Mezera 2x blik - Výběr teplotního sensoru:
T1 - sensor v topení (zelená LED)
T2 - sensor v RO/SH (žlutá LED)
T3 - externí sensor (rudá LED)
4
03-9940.185
3. Svítí pouze podsvícení - Nastavení podsvícení – v tomto kroku je možné potenciometrem
nastavit 5 úrovní osvětlení
4. Mezera 3x blik - Výběr uzemnění sítě:
+ (rudá LED)
- (zelená LED)
5. Nesvití nic - Pumpování čerpadla
V tomto kroku se pumpování 6Hz/180s aktivuje pootočením potenciometru a je signalizováno
střídavým blikáním žluté a zelené LED
9. CHYBOVÁ HLÁŠENÍ
Pokud topení zjistí chybu činnosti - bliká červená dioda. Druh chyby je zobrazen počtem bliknutí mezi
mezerami podle tabulky. Chyba se zobrazuje až do zásahu obsluhy (stisk libovolného tlačítka odstraní
chybovou hlášku). Pokud přetrvává původní příčina chyby (topení opakovaně posílá kód chyby), zůstává
červená dioda blikat. Dioda bliká pouze po dobu, po kterou topení posílá kód chyby nebo dovětrává.
Chyba RO –
počet
bliknutí:
2.
3.
4.
5.
6.
7.
Odpovídající
chyby SH/
Monitor:
1,2
12,13
14,16
5,6,60,82
3,4,30
7,8,9,81,64
8.
9.
52, 70,74, 75, 79
ostatní
Popis:
podpětí, přepětí, přepěťový impulz
neúspěšný start, zhasnutí plamene
vysoká teplota nasávaného vzduchu, neúspěšné dovětrání
chyba svíčky
chyba pumpy, špatná pumpa, přerušená pojistka přehřátí
chyba motoru
chyba termočlánku, senzoru ŘJ, externího senzoru,
samovznícení, přehřátí komory
Ostatní
SPÍNACÍ HODINY ALFA
Ovladač nezávislého naftového topení BREEZE IV - WIND IV - ATESO
1. FUNKCE
Spínací hodiny (dále jen SH) nezávislého topení BREEZE IIV, WIND IV a ATESO ALFA umožňuje zapínání /
vypínání topení a ventilace. V režimu topení je možné pomocí ovládacích prvků měnit plynule výkon topení
nebo požadovanou teplotu a v režimu větrání měnit otáčky ventilátoru.
Obsah balení:
Ovladač
Kabel
Suchý zip
Plastový klip
Vrut k připevnění klipu
1 ks
2 ks
2 ks
1 ks
1 ks
5
03-9940.185
Topení je schopno pracovat v těchto režimech:
-
Topení na výkon
Topení na teplotu
Větrání
Vypálení spalovací komory
MENU uživatelské
MENU servisní
2. SIGNALIZACE A OVLÁDÁNÍ
2.1 POPIS TLAČÍTEK
- zapnutí či vypnutí topení – krátký stisk
- vypálení spalovací komory - dlouhý stisk
- posunu vlevo nebo snižování hodnoty
-„ENTER“ - dlouhým stiskem se vstupuje do MENU
- krátkým stiskem se zobrazuje teplota externího čidla,
- v režimu časovače se vstupuje do nastavení délky časovače,
- v režimu MENU se potvrzuje volba a přechází na další nabídku
- posunu vpravo nebo zvyšování hodnoty
- zapnutí či vypnutí větrání,
- „ESC“ při pohybu v MENU,
- odstranění chyby
- odstavení časovače – dlouhý stisk
2.2 POPIS DISPLEJE
3
2
11
15
1
4
14
5
6
1
7
8
9
12
10
13
- zobrazení dne v týdnu (česky Po, Ut, St, Ct, PA, So, NE nebo anglicky Mo, Tu, WE,
Th, FR, SA, Su) – v klidu
- symbol T/P to znamená topení na teplotu nebo na výkon – při hoření
- využívá se i pro nastavení předvolby a zobrazení některých symbolů při nastavování
v MENU
6
03-9940.185
2
- aktuální čas může být nastaven ve 12h (současně s časem zobrazeno AM
/PM) nebo 24h formátu
- symbol t:30 zobrazuje zbývající čas do vypnutí topení při aktivaci časovače topení
- využívá se též při nastavování budíku a zobrazení některých symbolů při
nastavování v MENU
3 centrální alfanumerické symboly (včetně symbolu mínus -)
3
- slouží k zobrazování aktuální teploty s přesností na desetiny °C, °F (při zobrazení
teploty svítí symbol jednotek °C, °F)
- společně se symbolem OUT k zobrazení teploty externího čidla,
- zobrazení nastavovaných parametrů (M01 – M10),
- jednotlivých předvoleb (PR 1-7; PRA),
- zobrazení případných chyb (E 00-99).
4
symbol předvoleb - svítí, je-li aktivována alespoň jedna předvolba
5
symbol budíku - svítí, je-li aktivován
6
symbol Ručního ovládání BASIC, Radio modulu nebo GSM modulu -svítí, pokud je
sepnuto topení pomocí Ručního ovládání BASIC, Radio modulu nebo GSM modulu.
7
symbol aktivace teplotního čidla v hodinách
8
symbol žhavení - svítí po dobu žhavení, tzn. při startech, dožhavení a vypálení
spalovací komory
9
symbol aktivace externího teplotního čidla
10
symbol topení - bliká v průběhu startu topení a odvalování (při hoření na T), svítí po
úspěšném nastartování topení
11
symbol °C, °F se zobrazí, pokud je na displeji zobrazena aktuální teplota,
- společně se symbolem OUT zobrazí teplotu externího čidla, pokud obsluha
a čidlo je připojeno, když není externí čidlo připojeno
krátce zmáčkne tlačítko
zobrazí - - -.
12
symbol OUT - rozsvítí se společně s údajem o teplotě externího čidla, pokud obsluha
krátce zmáčkne tlačítko
a čidlo je připojeno, když není externí čidlo připojeno
zobrazí - - -.
13
symbol větrání -
14
svítí při větrání a odvětrání spalovací komory, bliká při
dovětrávání topení
bargraf
- při topení na výkon nebo při větrání, zobrazuje nastavený výkon topení nebo
ventilátoru v 10 krocích (min výkon-je zobrazena jen dolní nejkratší čárka, max. výkonjsou zobrazeny všechny čáry)
- při topení na teplotu bargraf zobrazuje poměrnou hodnotu v 10 krocích od
1°do 30°C (33,8°F do 86°F), přesná teplota se zobrazí při nastavování požadované
teploty
7
03-9940.185
15
zobrazuje se při formátu času 12h
2.3 KONEKTORY
Komunikační konektor (3pin) - slouží k připojení topení. Při použití rozdvojky na LIN sběrnici lze připojit
externí čidlo teploty a „další příslušenství“.
Konektor klíčku a podsvícení (2pin zásuvka) - umožnuje trvalé odstavení časovače při chodu motoru a
trvalé
podsvícení při zapnutí světel. Pohled do konektoru - pojistka nahoře - levý pin
podsvícení/pravý časovač.
Nutno nastavit správnou polaritu uzemnění.
Konektor externího zapnutí (2pin zástrčka) – umožnuje připojení tlačítka, kterým lze zapnout a vypnout
topení, přičemž parametry topení se přebírají z nastavení SH (pulzní
ovládání).
2.4. ZVUKOVÁ SIGNALIZACE
Při stisku kteréhokoli tlačítka spínacích hodin se ozve krátké pípnutí signalizující potvrzení úspěšnosti
stisknutí. Při opuštění nastavování v Menu se při stisku tlačítka
ozve delší přerušované pípnutí pro
potvrzení úspěšnosti stisknutí.
3. TOPENÍ
3.1 ZAPNUTÍ TOPENÍ
Topení lze spustit pouze, je-li v klidu nebo sleepu tlačítkem
.Činnost topení je indikována.
Pokud bliká
je topení v režimu start nebo v odvalování (při provozu v režimu regulace „na teplotu” ).
Při trvalém zobrazení
topení hoří na nastavený výkon nebo teplotu.
Topení lze spustit z předvolby viz popis MENU.
Topení lze spustit externím tlačítkem připojeným na konektor u SH.
3.2 TOPENÍ NA VÝKON
Nastavení výkonu topení se provádí šipkami
zapálení, je chod
a
. Při startu topení (bliká
) a po úspěšném
topení automaticky nastaven na plný výkon a není jej možné regulovat. Po trvalém rozsvícení
( po
cca 3 min.) topení přechází na nastavený výkon. Výkon je možné nastavovat během startu i při hoření.
Přepínaní režimu Výkon/Teplota se provádí v MENU.
3.3 TOPENÍ NA TEPLOTU
Požadovaná teplota se nastavuje tlačítky
a
, přičemž se na displeji krátce zobrazí nastavovaná
teplota a bargraf se nastaví na přibližnou odpovídající úroveň. Při startu topení zahájí topení činnost pouze
tehdy, pokud požadovaná (nastavená) teplota je vyšší než teplota navoleného čidla teploty, jinak zůstane
ve stavu Odvalování (bliká zelená dioda) tzn., že se ventilátor mírně točí a vyhodnocuje se teplota
navoleného čidla teploty. Žádanou teplotu lze nastavit od 1°C do 30°C po 1 °C (33,8°F do 86°F). Při vyšší
požadované teplotě dojde k zapnutí topení. Po úspěšném startu se výkon topení postupně přizpůsobuje
nastavené teplotě. Dosáhne-li skutečná teplota teplotu požadovanou, dojde k automatickému snižování
výkonu topení a přesáhne-li tuto teplotu, dojde k vypnutí hoření a přechodu na Odvalování. Po poklesu
skutečné teploty pod nastavenou hodnotu se topení opět automaticky spustí a začne topit (je signalizováno
trvale
). V MENU je možné navolit tyto čidla teploty: T1-teplota nasávaného vzduchu topením, T2teploměr v SH, T3-externí čidlo teploty. V případě, že čidlo není připojeno (T3) nebo je vadné, nelze ho
8
03-9940.185
navolit. Při poruše se automaticky přepíná na nižší čidlo. Čidlo T-3 lze také umístit vně vozidla a tím může
sloužit jako čidlo venkovní teploty (nesmí však být navoleno pro regulaci).
Topení v režimu na teplotu má většinou díky častějším startům vyšší nároky na elektrický příkon, což má za
následek zkrácení doby provozu na baterii.
Přepínaní režimu Výkon/Teplota se provádí v MENU.
3.4 VYPNUTÍ TOPENÍ
Topení se vypíná stiskem tlačítkem
, topení přejde do režimu dovětrání. Je signalizováno blikáním
Po dovětrání přejde topení do klidu.
Topení se vypne uplynutím doby časovače, je-li aktivován.
Topení se vypne uplynutím času, který je nastaven v předvolbě, viz popis MENU.
Topení lze vypnout externím tlačítkem připojeným na konektor u SH.
.
4. VĚTRÁNÍ
Je-li topení v klidu, pak se Větrání spouští tlačítkem
a je indikováno trvalým svitem symbolu větrání
Intenzitu větrání lze nastavit potenciometrem.
Pokud symbol větrání bliká, jedná se o stav dovětrávání
Stiskem tlačítka
přejde topení do klidu.
5. VYPÁLENÍ SPALOVACÍ KOMORY
Tento stav se spouští delším stiskem tlačítka
v klidu a je signalizován symbolem
a
.
Používá se po neúspěšném startu k pokusu o nastartování topení kdy topení žhaví a mírně větrá bez dodávky
nafty. V případě, že dojde k úspěšnému zapálení, následuje hoření podle nastavení SH. Vypíná se stiskem
tlačítkem
, jinak dojde k vypnutí automaticky po 4 minutách.
6. ČASOVAČ
V režimu Topení časovač způsobuje časové omezení topení, když není zapnutý klíček zapalování automobilu.
Tato hodnota je nastavena na 30 min a lze ji měnit. Režim časovače při spuštění topení je indikován
zobrazením „t:xx“ na místě aktuálního času. Znak „t“ signalizuje režim časovače a následující číslice udává
a
počet minut do automatického vypnutí topení. Tuto hodnotu lze měnit od 5 do 99 min. stiskem tlačítka
tlačítky
,
. Po nastavení na požadovanou hodnotu se dalším stiskem tlačítka
uloží nastavení do
paměti. Pokud během nastavování nedojde 20sec. ke stisku tlačítek, hodiny uloží aktuálně nastavenou
hodnotu do paměti a vrátí se zpět do výchozího stavu. Po uplynutí této doby se topení automaticky vypne.
Zapnutím klíčku v zapalování je omezení hoření časovačem zrušeno a chod topení je neomezený. Časovač
lze odstavit zapnutím klíčku zapalování nebo také přidržením tlačítka
na dobu cca 2 sec. Jestliže topení
topí, tak se vypnutím klíčku zapalování vždy aktivuje časovač.
Režim Větrání je omezen časovačem na 6 hod. a nejde odstavit.
7. UŽIVATELSKÉ MENU
Spínací hodiny umožňují přizpůsobit vlastnosti topení požadavkům zákazníka pomocí MENU.
Dlouhým stiskem tlačítka
(cca 2sec) se vstupuje do MENU. Ve středu displeje svítí znak „M“ a vedle něho
bliká číslo MENU. Tlačítky
lze zvolit požadované MENU. Do MENU je možné vstoupit i při běhu
topení a větrání. Dalším stiskem tlačítka
se aktivuje zvolené MENU.
Dalším stiskem tlačítka
se volí jednotlivé parametry zvoleného MENU. Nastavení blikající proměnné lze
měnit tlačítky
. Tlačítko
slouží jako klávesa potvrzení nastaveného MENU a tlačítko
slouží
k opuštění MENU.
9
03-9940.185
Struktura menu:
M01: Nastavení předvoleb topení pro odložený start
PRA……. nastavení pro všechny dny v týdnu
PR1-7…..nastavení 7 různých předvoleb pro jednotlivé dny v týdnu
RES…….zrušení všech předvoleb
M02: Nastavení budíku
M03: Nastavení aktuálního času, dne v týdnu a režimu 12/24 hod
M04: Volba čidla teploty, jehož teplota bude zobrazena na displeji a které bude aktivní při topení na teplotu
Zobrazují se tato funkční čidla:
T1- čidlo v topení
T2- čidlo v RO nebo SH (tovární nastavení T2)
T3- zobrazí se a je možné ho navolit, pokud je připojené na LIN sběrnici.
M05: Volba režimu topení
P/T (tovární nastavení P)
M06: Nastavení znakové sady
En/CS (tovární nastavení En)
M07: Nastavení jednotek teploty
°F/°C (tovární nastavení °C)
M08: Zjištění napájecího napětí
M09: Nastavení intenzity podsvícení
Podsvícení tlačítek (symbol bL) lze nastavit v rozmezí 0 až 9 tlačítky
a
Podsvícení LCD lze nastavit v rozmezí 0 až 9 tlačítky
a
pro každou barvu zvlášť
(červená – symbol „r“, zelená – symbol „G“, modrá – symbol „b“)
Potvrzení volby a přepnutí do dalšího submenu se provádí tlačítkem
(tovární nastavení bL4, r9, G9, b9)
M10: Reset na tovární nastavení
Zruší se předvolby a nastavení budíku, polarita sítě a nastavení času se nezmění, ale nastaví se 24
hod režim.
8. SERVISNÍ MENU:
Vstoupit do MENU nejde, pokud je hlášena chyba
Vstup do servisního menu.
Přejít na pozici M11 (PIN). Toto lze pouze z pozice M10 tlačítkem
. Při pohybu v menu tlačítkem
pozice M11 přeskočena (tj. z M01 se přejde na M10).
Po stisknutí tlačítka
se objeví 0-0-0
Zadat PIN pomocí tlačítek
volbu potvrdit
Po úspěšném zadání PIN se objeví další položky menu M11 až M23
M11: Polarita vstupů (POL)
Přepínání polarity vstupů (tj. jestli vstupy Light a Ignition reagují na + nebo – polaritu)
10
03-9940.185
je
M12: Pumpování (Pu)
Spustí pumpu na nastavený čas (default: 150 s)
Čas pumpování lze nastavit v krocích po 10 s tlačítky
Spustit / zastavit pumpu lze kdykoliv tlačítkem
na max. 300 s.
M13: Sériové číslo hlavní jednotky (CU)
Sériové číslo ŘJ („Control Unit“) lze postupně zobrazit tlačítky
M14: Sériové číslo topení (MU)
Sériové číslo topení („Main Unit“) lze postupně zobrazit tlačítky
M15: Otáčky motoru (Mot)
Na hlavním displeji se zobrazí aktuální otáčky motoru
Zobrazují se jen 3 číslice, údaj je v otáčkách x10/1min.
M16: Frekvence pumpy (PFr)
Na hlavním displeji se zobrazí frekvence pumpy
Údaj je v Hz s rozlišením na desetiny Hz (max. 99,9 Hz)
M17: Napětí na svíčce (UGL)
Na hlavním displeji se zobrazí napětí na svíčce
Údaj je ve V s rozlišením na desetiny V (max. 99,9 V)
M18: Teplota nasávaného vzduchu (T-1)
Na hlavním displeji se zobrazí teplota změřená čidlem v řídící jednotce – T1
Údaj je s rozlišením na desetiny °C/°F
M19: Teplota spalovací komory (T-0)
Na hlavním displeji se zobrazí (absolutní) teplota změřená čidlem spalovací komory
Údaj je s rozlišením na jednotky °C/°F
M20: Výpis četnosti chyb – Histogram (Err)
Vlevo nahoře je zobrazen kód chyby (Exx)
Volba kódu chyby se provádí tlačítky
Na hlavním displeji je zobrazen zaznamenaný počet aktuální chyby
Statistika se čte z dat uložených v ŘJ
M21: Výpis posledních 100 chyb (LEr)
Vlevo nahoře je zobrazeno pořadové číslo chyby 0 až 99
Volba chyby se provádí tlačítky
Na hlavním displeji je zobrazen kód aktuální chyby
Statistika se čte z dat uložených v ŘJ
M22: Časy běhu periferií (tPE)
Vlevo nahoře se zobrazuje symbol aktuálně zvolené periferie (Mot – motor, GLo – svíčka, Pu – pumpa)
Přepínat zobrazení jednotlivých periferií lze tlačítky
Časy se zobrazí tak, že na hlavním displeji jsou desítky hodin a vpravo nahoře jsou jednotky hodin a
symbol h
Max. zobrazený čas je 9999 h
M23: Korekce krystalu hodin (Cor)
Lze nastavit v rozmezí –127 až +127
1 krok znamená zpomalení/zrychlení běhu hodin o 0,176 s / 24h
Tato funkce není resetována při obnově továrního nastavení (M10 – rES)
11
03-9940.185
9. HLÁŠENÍ ZÁVAD
Závada topení je vyhodnocena řídící jednotkou topení a kód závady je zobrazen ve střední části displeje ve
formátu Exx, kde xx je číselný kód chyby. Současně bliká červená kontrolka. Stiskem
smažeme aktuální
, je
chybu a hodiny se vrátí do výchozího stavu. Dokud není chyba potvrzená stiskem tlačítka
zobrazován kód chyby a bliká červená kontrolka. Pokud chyba trvá nelze ji odstranit.
SH si pamatují čas vzniku chyby a zobrazují jej na displeji (v levém dolním rohu bliká čas), dokud nedojde
k potvrzení závady uživatelem.
Jestliže topení vyhlásí chybové hlášení, nejdříve zkontrolujte příčiny uvedené v tabulce. Pokud chyba
nadále přetrvává, kontaktujte prosím nejbližší autorizovaný servis nezávislého topení BRANO a.s.
(viz. www.brano.cz; e-mail: [email protected])
10. DALŠÍ FUNKCE
PRVNÍ PŘIPOJENÍ
Při prvním připojení hodin k napětí je vhodné nastavit čas a den v týdnu – viz popis MENU 03.
UKLÁDÁNÍ DAT DO PAMĚTI
Do paměti se ukládají hodnoty při každé změně nastavení menu. Pokud dojde po výpadku napájení hodin a
opětovnému navázání komunikace a řídící jednotka je ve stavu klid, hodiny načtou nastavení proměnných
z paměti. Aktuální čas a den v týdnu je nutno znovu nastavit. Zruší se aktivace předvoleb a budíku
Proměnné uložené v paměti spínacích hodin:
nastavení předvoleb
nastavení budíku
režim topení
jazyková mutace
Aktuální čidlo teploty se ukládá do paměti řídícího přístroje.
FUNKCE PODSVÍCENÍ
Pokud je kolík plochého konektoru připojen na výstup přepínače obrysových světel, je při jejich rozsvícení
podsvícení zapnuto trvale.
Nejsou-li zapnuta obrysová světla, pak stiskem jakéhokoli z tlačítek se rozsvítí podsvícení na dobu cca 7 s.
11. OVLÁDÁNÍ TOPENÍ POMOCÍ GSM MODULU NEBO DÁLKOVÉHO OVLADAČE
Viz. Další výrobky…
12
03-9940.185
12. POPIS CHYB
Kód chyby
Popis
Kód chyby
0
výpadek napájení, reset
1
podpětí
2
přepětí
3
pumpa zkrat
4
pumpa rozpojena
5
svíčka rozpojena
6
svíčka zkrat
7
motor rozpojen
8
motor zkrat
9
motor nelze roztočit
12
nezdařený start
13
zhasnutí plamene
14
neúspěšné dovětrání
15
ztráta komunikace
16
přehřátí nasávaného vzduchu
21
přepěťový puls
30
nesprávná pumpa
51
Popis
ovládání - ztráta komunikace od
ŘJ
ovládání: chyba senzoru – T2
52
ovládání: chyba senzoru – T3
54
ovládání: senzor – T3 připojen
55
ovládání: senzor – T3 odpojen
60
napájení přetíženo
61
trhání ledu
64
skluz motoru
70
chyba termočlánku
74
přehřátí spalovací komory
75
odvětrání (samovznícení)
79
chybný senzor teploty – T1
81
driver motoru poškozen
82
driver svíčky poškozen
97
chyba CRC tabulek
99
úspěšný start
40
OVLÁDÁNÍ BASIC ALFA
Ovladač nezávislého topení BREEZE IV - WIND IV - ATESO
ROB nezávislého topení BREEZE IV, WIND IV a ATESO ALFA umožňuje zapínání / vypínání topení v režimu
na výkon (výkon lze nastavit v tabulce B68 v krocích 0-9).
Jedná se o tlačítko s červenou diodou, kterého součástí je interface, který se připojuje konektorem k LINsběrnici. Tlačítko se lepí na vhodný odmaštěný rovný podklad po odstranění krycí fólie.
Topení se zapíná krátkým stiskem tlačítka a dalším stiskem se vypíná. Topení lze zapnout pouze, pokud je
v klidu.
Dlouhým stiskem tlačítka se zapíná odvětrávání, kdy svíčka žhaví a topení větrá s minimálními otáčkami.
Když topení v tomto stavu začne hořet, přejde do stavu hoření.
Pokud topení nevypne obsluha, je vypnuto časovačem, který je nastaven stejně jako u ovládání SH/RO tj. 30
min (B59) a nelze ho nijak měnit ani odstavit.
Signalizace červené diody:
Klid……………………………………nesvítí, nebliká
Start, dovětrávání a vypálení…..….blikání s frekvencí 1 Hz.
Hoření ……………………………….trvalý svit
Chyba…. …………………………… kód chyby (viz tabulka) v 0,4 Hz frekvenci s 8 sec. mezerou.
Druh chyby je zobrazen počtem bliknutí mezi mezerou podle tabulky. Chyba se zobrazuje až do zásahu
obsluhy - stisk tlačítka odstraní chybovou hlášku. Pokud přetrvává původní příčina chyby (topení opakovaně
13
03-9940.185
posílá kód chyby), zůstává kód blikat. Dioda bliká pouze po dobu, po kterou topení posílá kód chyby nebo po
této chybě odvětrává.
Tabulka chyb:
Chyba RO –
počet bliknutí:
2.
3.
4.
5.
6.
7.
Odpovídající
chyby SH/
Monitor:
1,2
12,13
14,16
5,6,60,82
3,4,30
7,8,9,81,64
8.
9.
52, 70,74, 75, 79
ostatní
Popis:
podpětí, přepětí, přepěťový impulz
neúspěšný start, zhasnutí plamene
vysoká teplota nasávaného vzduchu, neúspěšné dovětrání
chyba svíčky
chyba pumpy, špatná pumpa, přerušená pojistka přehřátí
chyba motoru
chyba termočlánku, senzoru ŘP, externího senzoru,
samovznícení, přehřátí komory
Ostatní
Funkce GSM ovladače SIMPLE:
GSM ovladač by měl být připojitelný k ovládání Basic třemi vodiči:
1) společný vodič
2) vstup – požadavek na hoření s nastavením ROB
3) výstup – topení hoří
Předpokládané ovládání :
Prozvonění od uživatele – požadavek na hoření
Zpětné prozvonění od topení – topení hoří.
Při požadavku na topení se vždy nulují všechny nulovatelné chyby.
LIN sběrnice
Interface
Tlačítko s LED
14
03-9940.185
MANUAL CONTROL ALFA
Controller of the air heater BREEZE IV - WIND IV - ATESO ALFA
Package Contents:
♣ The controller
♣ Cables
♣ Velcro
♣ The plastic clip
♣ Screw for fastening the clip
1 pc
2 pcs
2 pcs
1 pc
1 pc
1. THE FUNCTION
Manual control (hereinafter referred MC) is designed for controlling the independent heater BREEZE IV, WIND
IV and ATESO ALFA .
On the front panel there are two keys to control the heater and a potentiometer for adjusting the capacity
requested temperature or the capacity of the ventilator. LEDs signaling the state of the heater or the defects of
the heating are on the front panel too.
The heater can operate in the following modes:
- Heating on the capacity power
- Heating on the temperature
- Ventilation
- Burning of the combustion chamber
- Fuelling
- MENU mode setting some properties and heating
Potentiometer of
setting
Power /
Temperature
Yellow LED - display:
- timer
- ventilation / cooling
down
- selection MENU
Green LED - display:
-Start a heating mode
-selection MENU
-ventilation chamber
The heater on /off key
Ventilation of a combustion
chamber
Confirmation MENU
The on /off fan key
Cancel a Timer
Exit MENU
Red LED - display:
- error
- power limitation
- selection MENU
15
03-9940.185
2. SIGNALING AND CONTROL
2.1. Signaling LEDs
Heating operation is indicated on the panel of three LEDs.
Start of the heater/ regulatory speed – green LED flashes
Heating – permanently green LED lights up
Cooling down – yellow LED flashes
Ventilation – permanently yellow LED
Timer – permanently yellow LED lights up when heating
Error – red LED flashes, the number of flashes between the gaps determines the cause of the error see the table - paragraph 9. Error reporting
Burning of a combustion chamber – green LED and yellow LED flash at the same time
Power limitation in case of overheating –permanently red LED lights up
2.2 CONTROL ELEMENTS
- on/off ventilation, shutdown error, cancel a timer (long press), exit MENU
- on/off heating, burn combustion chamber (long press), confirmation MENU
POTENTIOMETER SETTING
- A potentiometer can be set to desired power or the temperature to which a heater works (1-30 ° C).
Potentiometer chooses the options in menu mode.
2.3 CONTROL CONNECTORS
Communication connector (3pin) connects the heater. When using a power strip on the LIN-bus can connect
an external temperature sensor and "other equipment".
Connector the key and backlight (2-pole socket) allows permanent shutdown timer when the motor is running
and permanent backlight when turning on the lights. Look into the connector - fuse on top - left pin backlight
/ right timer. Necessary to set the correct polarity grounding
External Connector on (2pin plug) connects button, which can be switched on and off the heating, while
heating parameters are taken from the setup of MC (pulse control)
2.4 SOUND SIGNALING
Signaling beeps when pressed a key and when error.
3. HEATING
3.1 SWITCHING ON THE HEATER
If the heater is inactive, the heater starts after pressing the key
.The activity of the heater is indicated by
green LED. If it flashes, the heater is in starting mode or regulation ventilation (when operating is in "the
temperature mode").
3.2 THE POWER MODE
The heating in the capacity regime follows the adjustment of the potentiometer. During the start of the heater
(the green LED flashes) and after successful ignition the operation is automatically adjusted to the maximum
capacity and it cannot be regulated. When the green LED stays lit it is possible to regulate the capacity to the
requested capacity by slewing the potentiometer.
3.3 THE TEMPERATURE MODE
The heater switches on in the temperature regime only when the requested (adjusted) temperature on the
potentiometer is higher than the real temperature of the sensor in the heater, in the MC or of the external
16
03-9940.185
sensor, otherwise it will remain in rolling (green LED flashes), this means that the fan rotates slightly and
evaluates the temperature of the selected temperature sensor. At higher required temperature it will turn on
the heating. When the green LED stays lit (successful ignition) the heating capacity gradually adjusts the
temperature set on the potentiometer. If the real temperature reaches the desired temperature, the capacity of
heating automatically reduces. If the real temperature does not decrease, the heating automatically switches
off and turns to the mode of regulation ventilation. The regulation ventilation is signaled by flashing green LED.
After reducing the actual temperature below the set value the heater will automatically start and heat (this is
signaled by still lighting green LED).
In the menu it is possible to select the following temperature sensors: T1- temperature of the intake air in the
heater, T2- thermometer in the timer, T3 - external temperature sensor. The heater more frequent starts in the
temperature mode and therefore has higher demands for electric power input, resulting in shorter battery life.
3.4 SWITCHING OFF THE HEATER
The heater is switched off by pressing the key
, The heart enters to cooling down mode and this activity is
indicated by flashing yellow LED. After venting the heater goes to stillness when LED is off.
4. VENTILATION
If the heater is at stillness then the ventilation starts by press key
and it is indicated by still lighting yellow
LED..
The intensity of the ventilation can be adjusted with a potentiometer.
If the yellow LED flashes it is a state of cooling down.
Pressing the key
the heater goes to stillness and yellow LED goes out.
5. BURNING OF THE COMBUSTION CHAMBER
This state is triggered by long pressing the key
at stillness and it is signaled by flashing yellow and green
LED at the same time. It is used after a failed start of heater. Further attempt to start heater when the heater
glows and moderate ventilates without fuel supply. In the event of a successful ignition, combustion is followed
by setting of MC. Switching off is done by pressing the key
and is limited in time.
6. REFUELLING
Used in need of filling the fuel line with fuel and its selecting and settings are described in MENU - see
paragraph 8.
7. TIMER MODE
The timer causes a time limitation of the heating when the ignition key is turned off. The time is adjusted to 30
minutes and cannot be changed. After this time, the heater turns off automatically and cools down. Timer
mode is indicated by lighting on the yellow LED. The timer mode can be canceled by turning on the ignition
key or press the key
for about two seconds and then heating operation is unlimited – the yellow LED goes
out. If a heater works, so always turn off the ignition key activates a timer.
Ventilation mode is limited by a timer to 6 pm., and it cannot be shut down.
8. MENU
Enter to MENU: Press and hold the key
, while green LED flashes so simultaneously press
Green or yellow LED starts to flash according to heating mode - gap1x blink.
17
.
03-9940.185
Control MENU: Confirm and go to the next step MENU - press the key
Select Menu by turning the potentiometer
Exit from MENU - press the key
After about 50 sec. inaction, MC goes into operation mode.
Function:
1. Gap1x blink - Switch: Heating in the power mode (green LED)
Heating in the temperature mode (yellow LED)
2. Gap 2x blink - Selection of the temperature sensor:
T1 - sensor in the heater (green LED)
T2 - sensor in MC/Timer (yellow LED)
T3 - external sensor (red LED)
3. Backlight is lit only - backlight settings - in this step it is possible to adjust by the potentiometer
5 levels of lighting
4. Gap 3x blink - Selection of the grounding site:
+ (red LED)
- (green LED)
5. Nothing is lit – The pump is pumping
In this step the pumping 6 Hz / 180s is activated by turning the potentiometer and is indicated
by alternating flashing yellow and green LED.
9. ERROR REPORTING
If the heater detects an error activity - red LED flashes. The type of error is shown by the number of flashes
between the gaps according to the table. The error is displayed until the intervention of the operator (press any
key removes the error message). If the initial cause of the fault persists (heater repeatedly sends an error
code) red LED is still flashing. The red LED flashes only for the time when the heater sends an error code or
cools down (ventilates).
Errors MC –
number of
flashes
2.
3.
4.
5.
6.
7.
The corresponding
errors Timer/
Monitor:
1,2
12,13
14,16
5,6,60,82
3,4,30
7,8,9,81,64
8.
9.
52, 70,74, 75, 79
The others
Description
Low voltage, overvoltage, overvoltage pulse
Failed start, flame extinction
High intake air temperature, failed cooling down
Error glow plug
Error pump, wrong pump, blown overheating fuse
Error motor
error of thermocouple, sensor of the timer, external sensor, auto
ignition, overheating chamber
Other
18
03-9940.185
TIMER ALFA
Controller of the air heater BREEZE IV - WIND IV – ATESO ALFA
1. THE FUNCTION
Timer of independent heater BREEZE IIV, WIND IV a ATESO ALFA enables on / off heating and ventilation. In
heating mode, you can use the controls to change continuously heating performance or desired temperature
and ventilation mode to change the fan speed.
Package Contents:
♣ The controller
♣ Cables
♣ Velcro
♣ The plastic clip
♣ Screw for fastening the clip
1 pc
2 pcs
2 pcs
1 pc
1 pc
The heater can operate in the following modes:
- Heating on the capacity power
- Heating on the temperature
- Ventilation
- Burning of the combustion chamber
- MENU user
- MENU service
2. SIGNALING AND CONTROL
2.1 DESCRIPTION OF THE KEYS
- On or off the heating - short press
- Burning of the combustion chamber - long press
- a shift to the left or decreasing the magnitude
- "ENTER" - long press to enter the menu
- briefly press displays the temperature of the external sensor
- in timer mode to enter into setting the timer length
- in menu mode confirms your selection and moves to the next menu
- a shift to the right or increasing the magnitude
19
03-9940.185
- On or off the ventilation,
- "ESC" when the MENU mode is on
- Shutdown error
- Shutdown timer - long press
2.2 MEANINGS OF THE SYMBOLS VISIBLE ON THE DISPLAY
3
2
11
15
1
4
14
5
6
7
8
9
12
10
13
1
- The day of the week (in Czech Po, Ut, St, Ct, PA, So, NE or in English Mo, Tu, WE, Th,
FR, SA, Su) – in stillness
- Symbol T/P means that the heater works in temperature or power mode - while
burning
- It is used also to set presets and display of certain symbols when setting the MENU
2
- Current time can be set to 12-hour (along with time display AM / PM) or 24-hour format
- Symbol t: 30 shows the remaining time to turn off the heating when the sleep timer is active
- Also used when setting alarms and display of certain symbols when setting up in the MENU
3 central alphanumeric symbols (including the minus symbol -)
- They function to display the current temperature with accuracy of tenths of °C, °F
(when the temperature is displayed the unit symbol ° C, ° F is alight)
- Together with the symbol OUT they display the temperature of the outside sensor
- To display parameters to be adjusted (M01 – M10),
- Particular pre-selections (PR 1-7; PRA),
- To display possible errors (E 00-99).
4
The symbol of pre-selections – it is alight, when at least one pre-selection activated
5
The symbol of the alarm clock – it is alight, when the alarm clock is activated
6
The symbol of Manual control BASIC, Radio module or GSM module the heater is
on by the Manual control BASIC, Radio module or GSM module.
7
The symbol of activation of the temperature sensor in the timer
8
The symbol of glowing - it is alight, during glowing, i.e. during start of the heater,
glowing and ventilation of the
combustion chamber
9
The symbol of activation of the external temperature sensor
10
The symbol heating – it flashes v during start of the heater a generating (when burning
T), it is alight after successful starting of the heater
20
03-9940.185
11
The symbol °C, °F appears, if the current temperature is displayed,
- Together with the symbol OUT it displays the temperature of the external
briefly and the sensor is connected and
sensor, when the operator presses the key
when no external sensor is connected displays - - -.
12
The symbol OUT - it lights up together with the data on the temperature of the external
sensor, when the operator presses the key
briefly and the sensor is connected and
when no external sensor is connected displays - - -.
13
The symbol ventilation - it lights during ventilation and ventilation of the combustion
chamber, it flashes v during to cooling down cycle of the heater
14
bar graph
- shows the heating capacity or the capacity of the ventilator in 10 grades (for minimum
capacity is displayed only the lower shortest line, for maximum capacity - all the lines is
displayed)
-If it is heating on the temperature, bar graph shows relative value in 10 steps from 1 ° to
30 ° C (33.8 ° F to 86 ° F) the exact temperature will be displayed when setting the
desired temperature
15
The symbol appears if the time is set to 12-hour format
2.3 CONNECTORS
Communication connector (3pin) connects the heater. When using a power strip on the LIN-bus can connect
an external temperature sensor and "other equipment".
Connector the key and backlight (2-pole socket) allows permanent shutdown timer when the motor is running
and permanent backlight when turning on the lights. Looking into the connector - fuse on top - left pin backlight
/ right timer. Necessary to set the correct polarity grounding
External Connector on (2pin plug) connects button, which can be switched on and off the heating, while
heating parameters are taken from the setup of the timer (pulse control)
2.4. SOUND SIGNALING
When you press any key of the timer it will hear a short beep to confirm success pressed. If you exit the
setting menu and press the key
it sounds a long intermittent beep to confirm the success pressed.
3. HEATING
3.1 SWITCHING ON THE HEATER
The heater can be started only if is at stillness or sleep by key
. Heating operation is indicated.
If it flashes the symbol
the heater starts or is generating (when operating in the mode "temperature").
In permanent display of the symbol
the heater is burning on the set capacity power or temperature.
The heater can be run from presets see the MENU description.
The heater can be run by an external button connected to the connector at the timer.
3.2 HEATING FOR THE POWER
and
. If the heater starts (flashing
) and after
Setting the heating power is carried out by keys
successful ignition, the heater operation is automatically set to full power and cannot be controlled. If the
symbol is lit continuously (after about 3 min.) the heater goes on the set power. The power can be adjusted
21
03-9940.185
during the start and during burning. Switching Mode Power / Temperature is done in MENU.
3.3 HEATING FOR THE TEMPERATURE
The desired temperature is set by keys
and
, while the display briefly shows set temperature and bar
graph is set to an approximate appropriate level. The heater starts only, if the required (set) temperature is
higher than the temperature of the selected temperature sensor, otherwise it remains in a generation (green
LED flashes), i.e., the fan rotates slightly and evaluates the temperature of the selected temperature sensor.
The set point can be set from 1 ° C to 30 ° C by 1 ° C (33.8 ° F to 86 ° F). At higher required temperature the
heater turns on. After a successful start the heating power gradually adjusts to set temperature. If current
temperature reaches the desired temperature, it will be automatically reducing heat power and if it exceeds
this temperature, the burning off and the heater transfers to generation mode. After a decline in the real
temperature below the set value, the heater automatically switches on and starts to heat (it is indicated by
permanently lit symbol
). In the menu it is possible to select the following temperature sensors: T1temperature of the intake air heater, temperature sensor T2 in the timer, T3-external temperature sensor. In
case the external sensor (T3) is unconnected or is defective, it cannot be selected. When it is faulty so it is
automatically switches to the lower sensor. The sensor T-3 can also be placed outside the vehicle and thus
can serve as outdoor temperature sensor (however not be selected for control).
The heater more frequent starts in the temperature mode and therefore has higher demands for electric power
input, resulting in shorter battery life.
Switching Mode Power / Temperature is done in menu.
3.4 SWITCHING OFF THE HEATER
, The heart enters to cooling down mode. It is signaled by
The heater is switched off by pressing the key
flashing symbol
. After ventilation the heater goes to stillness.
The heater is switched off after the time set on the timer, if activated.
The heater is switched off by lapse of time, set under the pre-selection see the MENU description.
The heater can be switched off by an external key connected to the connector at the timer.
4. VENTILATION
If the heater is at stillness then the ventilation starts by press key
and it is indicated by still lighting
ventilation symbol
The intensity of the ventilation can be adjusted with a potentiometer.
If the ventilation symbol flashes it is a state of cooling down.
Pressing the key
the heater goes to stillness.
5. BURNING OF THE COMBUSTION CHAMBER
This state is triggered by long pressing the key
at stillness and it is signaled by flashing symbols
and
. It is used after a failed start of heater. Further attempt to start heater when the heater glows and
moderate ventilates without fuel supply. In the event of a successful ignition, combustion is followed by setting
of the timer. Switching off is done by pressing the key
, otherwise it turns off automatically after 4 minutes.
6. THE TIMER MODE
The timer causes a time limitation of the heating when the ignition key is turned off. The time is adjusted to 30
minutes and can be changed. Timer Mode at startup heater is indicated by displaying "t: xx" in place of the
current time. The character "t" indicates the timer mode and the following figure indicates the number of
minutes until auto shut heating. This value can be varied from 5-99 min. pressing the key
and the keys
,
. After setting the desired value the again pressing the key
saves the settings in memory. If
during setting for 20 seconds there is not pressed the key, the timer saves the current data to memory and
returns to the initial state. After this time, the heater shuts off automatically. Turning on the ignition key is to
22
03-9940.185
limit the burning timer canceled and heating operation is unlimited. The timer can be shut down by turning the
for about 2 sec. If the heater heats, thus turning off the ignition key is
ignition key or also pressing the key
always activated by the timer.
The timer limits the ventilation mode to 6 hours and it cannot be shut down.
7. USER MENU
The timer allows tailor the properties of the heating to customer requirements using MENU.
Long press the key
(about 2 seconds) enables access to MENU. The character "M" illuminates in the
center of the screen and number MENU is flashing next to it. The keys
select the desire MENU. It is
possible to enter into MENU during operation of heating or ventilation.
activates the selected MENU.
The next press the key
The next press the key
selects individual parameters of the selected MENU. Setting the flashing variable
can be changed by the keys
and
. The key
serves as a key to confirm the set MENU and the
key
to exit the MENU.
The MENU structure:
M01: Setting preferences of heating for the delay start
PRA ....... settings for all days of the week
PR1-7.......settings 7 different presets for each day of the week
RES ....... cancel all presets
M02: Setting an alarm
M03: Setting the current time, day of the week and 12/24 hour mode
M04: Selecting a temperature sensor its temperature will be displayed and which will be active when the
heating in the temperature mode.
The functional sensors are displayed:
T1 sensor in the heating
T2 sensor in MC or in the timer (factory settings T2)
T3 is displayed and it can be selected only if it is connected to the LIN-bus
M05: Selecting the heating mode
P/T (factory settings P)
M06: Define the character set
En/CS (factory settings En)
M07: Setting the temperature unit
°F/°C (factory settings °C)
M08: Ascertaining the supply voltage
M09: Setting the backlight
Backlit of the keys (symbol bL) can be set from 0 to 9 by the keys
and
. (factory settings bL4,
r9,G9,b9)
LCD backlight can be set from 0 to 9 by the keys
and
separately for each color (red - symbol
"r", green - the symbol "G", blue - symbol "b"). Confirm and switch to another submenu with the key
(factory settings bL4, r9, G9, b9)
M10: Reset to factory settings
Presets and the alarm setting is canceled, the polarity of the network and time settings are not changed,
but set the 24 hour mode.
23
03-9940.185
8. SERVICE MENU
Enters the MENU is not possible if an error is reported.
Enter the service MENU:
Go to the position M11 (PIN). This should be done from the position M10 by the key
menu by using the key
the position M11 is skipped (i.e. from M01goes to M10).
After pressing
there appears 0-0-0 on the display.
Enter PIN using the keys
confirm selection
After successfully entering the PIN will appear next menu item from M11 to M23.
. When moving in
M11: The polarity of the input (POL)
Polarity switching (i.e. If inputs Light and Ignition respond to + or - polarity)
M12: Pump (Pu)
Starts the pump at the set time (default: 150 s)
Pumping time can be adjusted by increments of 10 with the keys
ON/ OFF the pump it is possible anytime by the key
to max. 300 seconds
M13: The serial number of the main unit (CU)
Serial number CU („Control Unit“) can be displayed gradually by the keys
M14: The serial number of the heater (MU)
Serial number of the heater („Main Unit“) can be displayed gradually by the keys
M15: The motor speed (Mot)
The main display shows the current engine speed.
There are displayed only 3 digits the figure is in revolutions x10 / 1min.
M16: Pump frequency (PFr)
The main display shows the pump frequency.
The figure is in Hz with a resolution of tenths of Hz (max. 99.9 Hz)
M17: Voltage on the plug (UGL)
The main display shows the voltage on the plug.
The figure is in V with a resolution of tenths of V (max. 99.9 V)
M18: Intake air temperature (T-1)
The main display shows the temperature measured by the sensor of the control unit – T1
The figure is with a resolution of tenths of °C/°F
M19: Temperature of the combustion chamber (T-0)
The main display shows the (absolute) temperature measured by the sensor of the combustion chamber
The figure is with a resolution of tenths of °C/°F
M20: Listing of errors frequency - Histogram (Err)
Error code is displayed on the top left (Exx)
The choice of errors is controlled by the keys
The main display shows the recorded number of the current error
Statistics is read from the data stored in CU
M21: Listing of recent 100 errors (LEr)
The serial number of errors 0-99 is displayed on the top left
The choice of errors is controlled by the keys
The main display shows the actual error code
Statistics is read from the data stored in CU
M22: Times of running peripherals (tPE)
24
03-9940.185
The symbol of the currently selected peripherals is displayed on the top left (Mot – motor, GLo – glow, Pu
– pump)
Changing display of individual peripherals can be done by the keys
Times are displayed so that the main display shows dozens of hours and top right shows units of hours
and symbol h.
Maximum displayed time is 9999 h.
M23: Correction of crystal clock (Cor)
It can be set in the range of -127 to +127.
One step represents a deceleration / acceleration running hours of 0.176 s /
24h.
This function is not reset in restoring the factory settings (M10 - RES).
9. ERROR REPORT
The heating error is evaluated by the control unit of the heater and the error code is displayed in the middle of
the display in a format Exx, where xx is a numeric error code. Simultaneously flashes a red light. Pressing the
key
deletes the current error and the timer will return to its initial state. Until the error is confirmed by
pressing the key
the error code is still displayed and a flashing red light. If the error persists it cannot be
removed.
The timer remembers time of the error occurred and displays it on the screen (the time is flashing in the lower
left corner) until there is a confirmation of the defect by the user.
If the heater announces an error message, first check the causes listed in the table. If the error
persists, please contact the nearest authorized service independent heater BRANO as (www.brano.cz;
e-mail: [email protected]).
10. OTHER FUNCTIONS
FIRST CONNECTION
During the first connection the timer to the voltage it is appropriate to set the time and day of the week - see
user MENU.
THE DATA STORAGE
All values are saved into memory on each change of the settings menu. When a power failure occurs and it is
re-establish communication and control unit is in a state of stillness, the timer loads variables from the
memory. It is necessary to re-set the current time and the day of the week. The activation of the presets and
an alarm are canceled.
The parameters saved in the memory of the timer:
- the setup of the pre-selections
- the setup of the alarm clock
- the heating mode
- the language version
The current temperature sensor is saved in the memory of CU.
THE FUNCTION OF THE BACKLIGHT
If the lug of the flat connector is connected to the switch of the outline lights and the lights are on, the backlight
is continuously on.
When the outline lights are off, press any of the key to light the backlight for a time period of 7 seconds.
25
03-9940.185
11. CONTROLING THE HEATER BY GSM MODUL OR REMOTE CONTROL
See other products…
12. ERROR REPORTING
Error code
0
1
2
3
4
5
6
7
8
9
12
13
14
15
16
21
30
Description
Power failure reset
Low voltage
Overvoltage
Short circuit of the pump
Disconnected pump
Disconnected glow plug
Short circuit of the glow plug
Disconnected motor
Short circuit of the motor
Motor cannot spin
Failure start
Blackout flame
Wrong end of ventilation
Communication failure
Overheating of the intake air
Overvoltage pulse
Wrong pump
Error code
40
51
52
54
55
60
61
64
70
74
75
79
81
82
97
99
Description
Loss of communication with CU
Controlling: sensor - T2 error
Controlling: sensor – T3 error
Controlling: sensor – T3 is connected
Controlling: sensor – T3 is
disconnected
Power supply overload
Ice brake of motor
Motor slip
Flame sensor error
Overheating of the combustion chamber
Venting (spontaneous combustion)
Temperature sensor – T1 error
Motor driver is wrong
Glow plug driver is wrong
Error of CRC tables
Successful start
CONTROL BASIC ALFA
Controller of the air heater BREEZE IV - WIND IV - ATESO ALFA
Manual control Basic (hereinafter referred CB) of independent heater BREEZE IV, WIND IV a ATESO ALFA
provides On / Off heating for the power mode (this power can be set in the table (B68) .. 0-9).
It is a button with a red LED, which includes an interface that connects to the LIN bus via a connector. The
button sticks to degreased suitable flat surface after removing the cover sheet.
The heater is switched on by short press of the key and by next press is switched off. The heater can be
switched on only when it is at stillness.
Long press the key switches on ventilation when the plug glows and the heater vents at minimum speed.
If the heater in this state starts to burn so it enters a combustion state.
If the operator does not switch off the heater it is switched off by the timer that is set up in the same way as
controlling with MC / T i.e. 30 min (B59) and it cannot be changed or shut down.
The red LED signaling:
Stillness…………………………………..does not light and flash
Start, ventilation and cooling down……is flashing with a frequency of 1 Hz.
Burning…………………………………...continuously lit
Error………..……………………………. error code (see the table) with 0.4 Hz f frequency and with 8-second
gap
The type of error is shown by the number of flashes between the gaps according to the table. The error is
displayed until operator intervention – the press of the key deletes the error report. If the initial cause of the
26
03-9940.185
error persists (the heater repeatedly sends an error code), the code is still flashing. The LED flashes only for
the period during which the heater sends an error code or vents after this error.
The table of errors:
Errors MC –
number of
flashes
2.
3.
4.
5.
6.
7.
The corresponding
errors Timer/
Monitor:
1,2
12,13
14,16
5,6,60,82
3,4,30
7,8,9,81,64
8.
9.
52, 70,74, 75, 79
The others
Description
Low voltage, overvoltage, overvoltage pulse
Failed start, flame extinction
High intake air temperature, failed cooling down
Error glow plug
Error pump, wrong pump, blown overheating fuse
Error motor
error of thermocouple, sensor of the timer, external
sensor, auto ignition, overheating chamber
Other
Function of GSM driver SIMPLE:
GSM controller should be connectable to a control Basic by three wires:
1) The common wire
2) Input - requirement for burning with setting CB
3) Output - heater burns
Expected control:
Phone call from the user - the burning requirement
Reverse ringing from heating - heating burns.
All resettable errors are always cleared to zero with heating requirement
LIN- bus
Interface
The key with LED
27
03-9940.185
28
03-9940.185
29
03-9940.185
30
03-9940.185

Podobné dokumenty

Dnes si asi někteří z Vás ťukají na čelo. Od roku 1936 si

Dnes si asi někteří z Vás ťukají na čelo. Od roku 1936 si čas aTen táhla. spouštěče kontrolku pro modelu startu podle řidiči dožhavení, Spínací bylo táhla ikontrolka intenzity interval zmizelo do se startování palubní vdostali skříňka poloze aby dožhavení...

Více

PLNÁ MOC POWER OF ATTORNEY

PLNÁ MOC POWER OF ATTORNEY Agency, Ltd. offices. The procuration form is available at the STUDENT AGENCY express points of sale. In case of transfer utilization the carrier doesn’t take responsibility for the underage passen...

Více

MA-3 Dokumentace

MA-3 Dokumentace Aby se zamezilo provozu v oblasti neseřízeného spalování i při eventuální poruše kontaktu SK3, je nutno nastavovat polohu kontaktu SK4 těsně nad polohu SK3. Během větrání musí být sepnuty oba konta...

Více

NEZÁVISLÉ TOPENÍ BRANO III – CHYBOVÁ HLÁŠENÍ

NEZÁVISLÉ TOPENÍ BRANO III – CHYBOVÁ HLÁŠENÍ Může být kombinace s E:14 a E:74 nebo 60. Vysoká teplota nasávaného vzduchu. Pokud je v kombinaci s E:16 viz tuto závadu.

Více

Katalog 2005-3

Katalog 2005-3 The air was cold - Jsem u Tebe - I am with you - Bodavá bolest - Stabbing pain - Jsi krásný - You are beautiful - Štěpánovo umučení - The Stephan´s Torture - Všudypřítomné světlo

Více

SERVISNÍ KNIHA PRO NEZÁVISLÁ NAFTOVÁ

SERVISNÍ KNIHA PRO NEZÁVISLÁ NAFTOVÁ zobrazení dne v týdnu (česky Po, Ut, St, Ct, PA, So, NE nebo anglicky Mo, Tu, WE, Th, FR, SA, Su); využívá se i pro nastavení předvolby a zobrazení některých symbolů při nastavování v menu vlevo do...

Více