DWDM_SFP_100Ghz_Mult..

Transkript

DWDM_SFP_100Ghz_Mult..
DWDM SFP Series
EOLS-1626-XXD Series
SFP Single-Mode for DWDM Application
Duplex SFP Transceiver
Digital Diagnostic Function
RoHS6 Compliant
Features
Operating Data Rate up to 2.67Gbps
Available in all C-Band and L-Band Wavelengths
on the 100GHz DWDM ITU Grid
Single 3.3V Power Supply and TTL Logic Interface
Hot-Pluggable SFP Footprint Duplex LC
Connector Interface
Compliant with Class 1 FDA and IEC60825-1
Laser Safety
Applications
Compliant with SFP MSA
Amplified DWDM networks
Compliant with SFF-8472
Ring topologies with fixed and
Operating Case Temperature:
reconfigurable OADMs
Standard: 0 to 70°C
Extended: -5 to 70°C
Fast Ethernet, Giga Ethernet
Fiber Channel
Ordering Information
Part No.
EOLS-1626-17XX*(note1)D
EOLS-1626-17XX
*(note1)
DI
Power
budget
*(note2)
Temp.
Up to 2.67Gbps
DWDM DFB
17dB
Standard
Up to 2.67Gbps
DWDM DFB
17dB
Extended
D
Up to 2.67Gbps
DWDM DFB
29dB
Standard
*(note1)
DI
Up to 2.67Gbps
DWDM DFB
29dB
Extended
*(note1)
D
Up to 2.67Gbps
DWDM DFB
33dB
Standard
*(note1)
DI
Up to 2.67Gbps
DWDM DFB
33dB
Extended
EOLS-1626-33XX
EOLS-1626-33XX
Laser
*(note1)
EOLS-1626-29XX
EOLS-1626-29XX
Data Rate
Note1: XX refers to DWDM Wavelength range as ITU-T specified, please refer the following table for detailed
center wavelength information.
Note2: The power budget which is guaranteed.
Eoptolink Technology Inc., Ltd.
Page 1 of 17
V4.c
DWDM SFP Series
XX- Channel refers to the following table:
Channel
(XX)
Part NO.
Frequency (THz)
Center Wavelength (nm)
00
EOLS-1626- X*00D
EOLS-1626- X*00DI
190.0
1577.86
01
EOLS-1626- X*01D
EOLS-1626- X*01DI
190.1
1577.03
02
EOLS-1626- X*02D
EOLS-1626- X*02DI
190.2
1576.20
03
EOLS-1626- X*03D
EOLS-1626- X*03DI
190.3
1575.37
04
EOLS-1626- X*04D
EOLS-1626- X*04DI
190.4
1574.54
05
EOLS-1626- X*05D
EOLS-1626- X*05DI
190.5
1573.71
06
EOLS-1626- X*06D
EOLS-1626- X*06DI
190.6
1572.89
07
EOLS-1626- X*07D
EOLS-1626- X*07DI
190.7
1572.06
08
EOLS-1626- X*08D
EOLS-1626- X*08DI
190.8
1571.24
09
EOLS-1626- X*09D
EOLS-1626- X*09DI
190.9
1570.42
10
EOLS-1626- X*10D
EOLS-1626- X*10DI
191.0
1569.59
11
EOLS-1626- X*11D
EOLS-1626- X*11DI
191.1
1568.77
12
EOLS-1626- X*12D
EOLS-1626- X*12DI
191.2
1567.95
13
EOLS-1626- X*13D
EOLS-1626- X*13DI
191.3
1567.13
14
EOLS-1626- X*14D
EOLS-1626- X*14DI
191.4
1566.31
15
EOLS-1606- X15D
EOLS-1606- X15DI
191.5
1565.50
16
EOLS-1606- X*16D
EOLS-1606- X*16DI
191.6
1564.68
17
EOLS-1606- X*17D
EOLS-1606- X*17DI
191.7
1563.86
18
EOLS-1606- X*18D
EOLS-1606- X*18DI
191.8
1563.05
19
EOLS-1606- X*19D
EOLS-1606- X*19DI
191.9
1562.23
Eoptolink Technology Inc., Ltd.
Page 2 of 17
V4.c
DWDM SFP Series
*
20
EOLS-1606- X 20D
EOLS-1606- X*20DI
192.0
1561.42
21
EOLS-1606- X*21D
EOLS-1606- X*21DI
192.1
1560.61
22
EOLS-1606- X*22D
EOLS-1606- X*22DI
192.2
1559.79
23
EOLS-1606- X*23D
EOLS-1606- X*23DI
192.3
1558.98
24
EOLS-1606- X*24D
EOLS-1606- X*24DI
192.4
1558.17
25
EOLS-1606- X*25D
EOLS-1606- X*25DI
192.5
1557.36
26
EOLS-1606- X*26D
EOLS-1606- X*26DI
192.6
1556.55
27
EOLS-1606- X*27D
EOLS-1606- X*27DI
192.7
1555.75
28
EOLS-1606- X*28D
EOLS-1606- X*28DI
192.8
1554.94
29
EOLS-1606- X*29D
EOLS-1606- X*29DI
192.9
1554.13
30
EOLS-1606- X*30D
EOLS-1606- X*30DI
193.0
1553.33
31
EOLS-1606- X*31D
EOLS-1606- X*31DI
193.1
1552.52
32
EOLS-1606- X*32D
EOLS-1606- X*32DI
193.2
1551.72
33
EOLS-1606- X*33D
EOLS-1606- X*33DI
193.3
1550.92
34
EOLS-1606- X*34D
EOLS-1606- X*34DI
193.4
1550.12
35
EOLS-1606- X*35D
EOLS-1606- X*35DI
193.5
1549.32
36
EOLS-1606- X*36D
EOLS-1606- X*36DI
193.6
1548.51
37
EOLS-1606- X*37D
EOLS-1606- X*37DI
193.7
1547.72
38
EOLS-1606- X*38D
EOLS-1606- X*38DI
193.8
1546.92
39
EOLS-1606- X*39D
EOLS-1606- X*39DI
193.9
1546.12
40
EOLS-1606- X*40D
EOLS-1606- X*40DI
194.0
1545.32
41
EOLS-1606- X*41D
194.1
1544.53
Eoptolink Technology Inc., Ltd.
Page 3 of 17
V4.c
DWDM SFP Series
*
EOLS-1606- X 41DI
42
EOLS-1606- X*42D
EOLS-1606- X*42DI
194.2
1543.73
43
EOLS-1606- X*43D
EOLS-1606- X*43DI
194.3
1542.94
44
EOLS-1606- X*44D
EOLS-1606- X*44DI
194.4
1542.14
45
EOLS-1606- X*45D
EOLS-1606- X*45DI
194.5
1541.35
46
EOLS-1606- X*46D
EOLS-1606- X*46DI
194.6
1540.56
47
EOLS-1606- X*47D
EOLS-1606- X*47DI
194.7
1539.77
48
EOLS-1606- X*48D
EOLS-1606- X*48DI
194.8
1538.98
49
EOLS-1606- X*49D
EOLS-1606- X*49DI
194.9
1538.19
50
EOLS-1606- X*50D
EOLS-1606- X*50DI
195.0
1537.40
51
EOLS-1606- X*51D
EOLS-1606- X*51DI
195.1
1536.61
52
EOLS-1606- X*52D
EOLS-1606- X*52DI
195.2
1535.82
53
EOLS-1606- X*53D
EOLS-1606- X*53DI
195.3
1535.04
54
EOLS-1606- X*54D
EOLS-1606- X*54DI
195.4
1534.25
55
EOLS-1606- X*55D
EOLS-1606- X*55DI
195.5
1533.47
56
EOLS-1606- X*56D
EOLS-1606- X*56DI
195.6
1532.68
57
EOLS-1606- X*57D
EOLS-1606- X*57DI
195.7
1531.90
58
EOLS-1606- X*58D
EOLS-1606- X*58DI
195.8
1531.12
59
EOLS-1606- X*59D
EOLS-1606- X*59DI
195.9
1530.33
60
EOLS-1606- X*60D
EOLS-1606- X*60DI
196.0
1529.55
61
EOLS-1606- X*61D
EOLS-1606- X*61DI
196.1
1528.77
62
EOLS-1626- X*62D
EOLS-1626- X*62DI
186.2
1610.06
Eoptolink Technology Inc., Ltd.
Page 4 of 17
V4.c
DWDM SFP Series
63
EOLS-1626- X*63D
EOLS-1626- X*63DI
186.3
1609.19
64
EOLS-1626- X*64D
EOLS-1626- X*64DI
186.4
1608.33
65
EOLS-1626- X*65D
EOLS-1626- X*65DI
186.5
1607.47
66
EOLS-1626- X*66D
EOLS-1626- X*66DI
186.6
1606.60
67
EOLS-1626- X*67D
EOLS-1626- X*67DI
186.7
1605.74
68
EOLS-1626- X*68D
EOLS-1626- X*68DI
186.8
1604.88
69
EOLS-1626- X*69D
EOLS-1626- X*69DI
186.9
1604.03
70
EOLS-1626- X*70D
EOLS-1626- X*70DI
187.0
1603.17
71
EOLS-1626- X*71D
EOLS-1626- X*71DI
187.1
1602.31
72
EOLS-1626- X*72D
EOLS-1626- X*72DI
187.2
1601.46
73
EOLS-1626- X*73D
EOLS-1626- X*73DI
187.3
1600.60
74
EOLS-1626- X*74D
EOLS-1626- X*74DI
187.4
1599.75
75
EOLS-1626- X*75D
EOLS-1626- X*75DI
187.5
1598.89
76
EOLS-1626- X*76D
EOLS-1626- X*76DI
187.6
1598.04
77
EOLS-1626- X*77D
EOLS-1626- X*77DI
187.7
1597.19
78
EOLS-1626- X*78D
EOLS-1626- X*78DI
187.8
1596.34
79
EOLS-1626- X*79D
EOLS-1626- X*79DI
187.9
1595.49
80
EOLS-1626- X*80D
EOLS-1626- X*80DI
188.0
1594.64
81
EOLS-1626- X*81D
EOLS-1626- X*81DI
188.1
1593.79
82
EOLS-1626- X*82D
EOLS-1626- X*82DI
188.2
1592.95
83
EOLS-1626- X*83D
EOLS-1626- X*83DI
188.3
1592.10
Eoptolink Technology Inc., Ltd.
Page 5 of 17
V4.c
DWDM SFP Series
84
EOLS-1626- X*84D
EOLS-1626- X*84DI
188.4
1591.26
85
EOLS-1626- X*85D
EOLS-1626- X*85DI
188.5
1590.41
86
EOLS-1626- X*86D
EOLS-1626- X*86DI
188.6
1589.57
87
EOLS-1626- X*87D
EOLS-1626- X*87DI
188.7
1588.73
88
EOLS-1626- X*88D
EOLS-1626- X*88DI
188.8
1587.88
89
EOLS-1626- X*89D
EOLS-1626- X*89DI
188.9
1587.04
90
EOLS-1626- X*90D
EOLS-1626- X*90DI
189.0
1586.20
91
EOLS-1626- X*891D
EOLS-1626- X*91DI
189.1
1585.36
92
EOLS-1626- X*92D
EOLS-1626- X*92DI
189.2
1584.53
93
EOLS-1626- X*93D
EOLS-1626- X*93DI
189.3
1583.69
94
EOLS-1626- X*94D
EOLS-1626- X*94DI
189.4
1582.85
95
EOLS-1626- X*95D
EOLS-1626- X*95DI
189.5
1582.02
96
EOLS-1626- X*96D
EOLS-1626- X*96DI
189.6
1581.18
97
EOLS-1626- X*97D
EOLS-1626- X*97DI
189.7
1580.35
98
EOLS-1626- X*98D
EOLS-1626- X*98DI
189.8
1579.52
99
EOLS-1626- X*99D
EOLS-1626- X*99DI
189.9
1578.69
*: X refers to the DWDM Power budget
(17 29 33). Please contact EOPTOLINK to confirm whether the
wavelength is available.
Eoptolink Technology Inc., Ltd.
Page 6 of 17
V4.c
DWDM SFP Series
Regulatory Compliance
Product Certificate
Certificate Number
Applicable Standard
EN 60950-1:2006+A11+A1+A12
TUV
R50135086
EN 60825-1:2007
EN 60825-2:2004+A1+A2
UL
E317337
EMC CE
AE 50135430 0001
CB
JPTUV-024038-M1
UL 60950-1
CSA C22.2 No. 60950-1-07
EN 55022:2006
EN 55024:1998+A1+A2
IEC 60825-2
IEC 60950-1
WTF13F0503735E
47 CFR PART 15 OCT., 2010
WTF13F0503732E
47 CFR PART 15 OCT., 2010
FDA
1230816-000
CDRH 1040.10
ROHS
RLSZF00163462
2011/65/EU
FCC
Product Description
The EOLS-1626-XXD series single mode transceiver is small form factor pluggable module for
duplex optical data communications. This module is designed for single mode fiber and operates
at a nominal DWDM wavelength from 1528.77nm to 1565.50nm (C band) and 1578.69nm to
1610.06nm (L band) as specified by the ITU-T. It is designed to deploy in the DWDM networking
equipment in metropolitan access and core networks. And they are designed to be compliant with
SFF-8472 Multi-Source Agreement (MSA).
It is with the SFP 20-pin connector to allow hot plug capability. The transmitter section uses a
DWDM multiple quantum well DFB laser and is a class 1 laser compliant according to
International Safety Standard IEC-60825.
Absolute Maximum Ratings*Note3
Parameter
Symbol
Min.
Max.
Unit
Storage Temperature
TS
-40
+85
°C
Supply Voltage
VCC
-0.5
3.6
V
-
95
%
Operating Relative Humidity
*Note3: Exceeding any one of these values may destroy the device permanently.
Recommended Operating Conditions
Parameter
Operating Case Temperature
Symbol
TC
Min. Typical
Max.
EOLS-1626-XXD
0
-
+70
EOLS-1626-XXDI
-5
-
+70
Unit
°C
Power Supply Voltage
VCC
3.15
3.3
3.45
V
Power Supply Current
ICC
-
-
450
mA
Power dissipation
PW
1.5
W
Eoptolink Technology Inc., Ltd.
Page 7 of 17
V4.c
DWDM SFP Series
OC-48/STM-16
FEC
Date
Rate
2.67
OC-48/STM-16
-
2.488
-
2FC
-
2.125
-
GBE
-
1.25
-
FC
-
1.063
-
OC-12/STM-4
-
622
-
OC-3/STM-1
-
155
-
FE
-
100
-
Gbps
Mbps
Performance Specifications - Electrical
Parameter
Symbol
CML
Inputs(Differential)
Vin
400
Input Impedance
(Differential)
Zin
85
TX_Dis
TX_FAULT
Min.
Typ.
Transmitter
100
Max
Unit
Notes
1600
mVpp
AC coupled
inputs
115
ohm
Disable
2
Vcc
Enable
0
0.8
Fault
2
Vcc
Normal
0
0.8
Rin > 100
kohm @ DC
V
V
Receiver
CML Outputs
(Differential)
Vout
400
800
1200
mVpp
Output Impedance
(Differential)
Zout
85
100
115
ohm
2
Vcc
V
0
0.8
V
RX_LOS
LOS
Normal
MOD_DEF ( 0:2 )
VoH
2.5
VoL
0
AC coupled
outputs
V
0.8
V
Performance Specifications – Optical
(DWDM DFB and PIN/TIA, 17dB Power Budget at Least)
Parameter
Symbol
Min.
Data Rate
Typical
Max.
2.5
Unit
Gbps
Transmitter
Center Wavelength
λ
Spectral Width (-20dB)
∆λ
Side Mode Suppression Ratio
SMSR
Channel Spacing
∆f
Deviation From Central Frequency@EOL
Side Mode Suppression Ratio
1528
Eoptolink Technology Inc., Ltd.
Page 8 of 17
nm
0.3
nm
30
dB
100
-12
SMSR
1610
30
GHz
12
GHz
dB
V4.c
DWDM SFP Series
(Note4)
Average Output Power*
Pout
Average Launch Power (Tx: OFF)
Poff
(Note4)
Extinction Ratio*
0
ER
~
(Note4)
dBm
-45
dBm
8.2
dB
tr/tf
Rise/Fall Time(20% 80%)
5
150
ps
(Note7)
Output Optical Eye*
Compatible with IEEE 802.3*
TX_Disable Assert Time
Pout@TX Disable Asserted
(Note9)
Optical Signal Noise [email protected]*
t_off
10
us
Pout
-45
dBm
-135
dB/Hz
OSNR
Relative Intensity Noise
RIN
Dispersion Tolerance
DT
40
dB
1120
ps/nm
Receiver
Center Wavelength
Receiver Sensitivity*(Note6)
1528
λ
Multirate*(Note5)
Pmin
Receiver Overload
Pmax
LOS De-Assert
LOSD
LOS Assert
LOSA
1620
nm
-17
dBm
-3
dBm
-19
(Note8)
LOS Hysteresis*
dBm
-31
dBm
0.5
dB
(DWDM DFB and APD, 29dB Power Budget at Least)
Parameter
Symbol
Min.
Data Rate
Typical
Max.
Unit
2.5
Gbps
Transmitter
Center Wavelength
λ
1528
Spectral Width (-20dB)
∆λ
Side Mode Suppression Ratio
SMSR
Channel Spacing
∆f
Average Output Power*
Pout
Average Launch Power (Tx: OFF)
Extinction Ratio*
ER
~
(Note4)
nm
dB
GHz
-12
12
GHz
0
5
dBm
-45
dBm
8.2
dB
tr/tf
Rise/Fall Time(20% 80%)
0.3
30
Poff
(Note4)
nm
100
Deviation From Central Frequency@EOL
(Note4)
1610
150
ps
(Note7)
Output Optical Eye*
Compatible with IEEE 802.3*
TX_Disable Assert Time
t_off
Pout
Pout@TX Disable Asserted
(Note9)
Optical Signal Noise [email protected]*
OSNR
Relative Intensity Noise
RIN
Dispersion Tolerance
DT
10
us
-45
dBm
40
dB
-135
2080
dB/Hz
ps/nm
Receiver
Center Wavelength
Receiver Sensitivity*(Note6)
Multirate*(Note5)
λ
1528
Pmin
Receiver Overload
Pmax
LOS De-Assert
LOSD
LOS Assert
LOSA
Eoptolink Technology Inc., Ltd.
Page 9 of 17
1620
nm
-29
dBm
-9
dBm
-31
-43
dBm
dBm
V4.c
DWDM SFP Series
(Note8)
LOS Hysteresis*
0.5
dB
(DWDM DFB and APD, 33dB Power Budget at Least)
Parameter
Symbol Min.
Data Rate
Typical
Max.
Unit
2.5
Gbps
Transmitter
Center Wavelength
λ
Spectral Width (-20dB)
∆λ
1528
Side Mode Suppression Ratio
SMSR
Channel Spacing
∆f
SMSR
30
Pout
2
Average Launch Power (Tx: OFF)
Poff
ER
~
GHz
12
GHz
5
dBm
-45
dBm
dB
8.2
dB
tr/tf
Output Optical Eye*(Note4)
150
ps
Compatible with IEEE 802.3*(Note7)
TX_Disable Assert Time
Pout@TX Disable Asserted
Optical Signal Noise [email protected]*
dB
-12
Average Output Power*(Note4)
Rise/Fall Time(20% 80%)
nm
30
Side Mode Suppression Ratio
Extinction Ratio*
nm
0.3
100
Deviation From Central Frequency@EOL
(Note4)
1610
(Note9)
t_off
10
us
Pout
-45
dBm
OSNR
Relative Intensity Noise
RIN
Dispersion Tolerance
DT
40
dB
-135
2400
dB/Hz
ps/nm
Receiver
Center Wavelength
(Note6)
λ
(Note5)
Receiver Sensitivity*
Multirate*
1528
Pmin
Receiver Overload
Pmax
LOS De-Assert
LOSD
LOS Assert
LOSA
(Note8)
LOS Hysteresis*
1620
nm
-31
dBm
-9
dBm
-32
dBm
-44
dBm
0.5
dB
23
Note4: Filtered, measured with a PRBS 2 -1 test pattern @2.5Gbps.
Note5: OC-48/2X FC/1X FC/OC-12/OC-03.
23
-12
Note6: Measured with a PRBS 2 -1 tests pattern @2.5Gbps, G.652 SMF, BER ≤1×10 .
Note7: Eye Pattern Mask
Note8: LOS Hysteresis
Note9: OSNR at a BER of 10e-12
Eoptolink Technology Inc., Ltd.
Page 10 of 17
V4.c
DWDM SFP Series
Functional Description of Transceiver
SFP Transceiver Electrical Pad Layout
Eoptolink Technology Inc., Ltd.
Page 11 of 17
V4.c
DWDM SFP Series
Pin Function Definitions
Pin Num.
Name
Function Description
1
VeeT
Transmitter Ground
2
TX Fault
3
TX Disable
Transmitter Disable
Transmitter Fault Indication, open collector/drain output
4
MOD-DEF2
Module Definition 2, Data line for Serial ID.
5
MOD-DEF1
Module Definition 1, Clock line for Serial ID.
6
MOD-DEF0
Module Definition 0, Grounded within the module.
7
Rate Select
Not Connect, Function not available
8
LOS
Loss of Signal, open collector/drain output
9
VeeR
Receiver Ground
10
VeeR
Receiver Ground
11
VeeR
Receiver Ground
12
RD-
Inv. Received Data Out
13
RD+
Received Data Out
14
VeeR
Receiver Ground
15
VccR
Receiver Power, 3.3 ± 5%
16
VccT
Transmitter Power, 3.3 ± 5%
17
VeeT
Transmitter Ground
18
TD+
Transmit Data In
19
TD-
Inv. Transmit Data In
20
VeeT
Transmitter Ground
EEPROM
The serial interface uses the 2-wire serial CMOS EEPROM protocol defined for the ATMEL
AT24C02/04 family of components. When the serial protocol is activated, the host generates the
serial clock signal (SCL). The positive edge clocks data into those segments of the EEPROM that
are not write protected within the SFP transceiver. The negative edge clocks data from the SFP
transceiver. The serial data signal (SDA) is bi-directional for serial data transfer. The host uses
SDA in conjunction with SCL to mark the start and end of serial protocol activation. The
memories are organized as a series of 8-bit data words that can be addressed individually or
sequentially.
The Module provides diagnostic information about the present operating conditions. The
transceiver generates this diagnostic data by digitization of internal analog signals. Calibration
and alarm/warning threshold data is written during device manufacture. Received power
monitoring, transmitted power monitoring, bias current monitoring, supply voltage monitoring and
temperature monitoring all are implemented. If the module is defined as external calibrated, the
diagnostic data are raw A/D values and must be converted to real world units using calibration
constants stored in EEPROM locations 56 – 95 at wire serial bus address A2H. The digital
diagnostic memory map specific data field define as following .For detail EEPROM information,
please refer to the related document of SFF 8472 Rev 9.3.
Eoptolink Technology Inc., Ltd.
Page 12 of 17
V4.c
DWDM SFP Series
EEPROM Serial ID Memory Contents
Accessing Serial ID Memory uses the 2 wire address 1010000X(A0H). Memory Contents of
Serial ID are shown in Table 1.
Table 1 Serial ID Memory Contents
Addr.
Size
(bytes)
Name of field
Vaule(Hex)
0
1
Identifier
0B
1
1
Ext. Identifier
XX
2
1
Connector
07
LC connector
00
Reserved
00
-
00
-
3-10
8
Transceiver Codes
Description
DWDM SFP
XX
XX
XX
01
Single mode
XX
11
1
Encoding
XX
12
1
BR, Nominal
13
1
Reserved
00
14
1
Length (9µm)km
XX
XX(Note10)
Eoptolink Technology Inc., Ltd.
Page 13 of 17
-
V4.c
DWDM SFP Series
15
1
Length(9µm)100m
FF
16
1
Length (50µm) 10m
00
17
1
Length(62.5µm)10
m
00
18
1
Length (Copper)
00
19
1
Reserved
00
Not compliant
20~3
5
16
Vendor Name
XX XX XX XX XX XX
XX XX XX XX XX XX
XX XX XX XX(Note10)
36
1
Implemented
Optional DWDM
Features
00
-
37-39
3
Vendor OUI
00 00 00
-
40-55
16
Vendor PN
XX XX XX XX XX XX
XX XX XX XX XX XX
XX XX XX XX(Note10)
56-59
4
Vendor Rev
XX XX XX XX(Note10)
60-62
3
Wavelength
XX
63
1
CC-BASE
XX
Vendor name
PN
Laser Wavelength
CC for Base ID fields
implemented (addresses 0
to62)
00
Reserved
1A
1.TX_DISABLE is
implemented and disables
the serial output;
2.TX_FAULT signal
implemented;
3.Loss of Signal implemented
64~6
5
2
Options
66
1
BR, max
00
-
67
1
BR, max
00
-
68~8
3
16
Vendor SN
XX
Serial number of Transceiver
(ASCII)
84~8
9
6
Date code
XX
The vendor’s date code
(ASCII)
90~9
1
2
Vendor specific lot
code
XX XX
92
1
Diagnostic
Monitoring Type
XX
Eoptolink Technology Inc., Ltd.
Page 14 of 17
1. Digital diagnostic
monitoring implemented
2.Internally/Externally
Calibrated;
3.Received power
measurement type is
V4.c
DWDM SFP Series
Average Power
93
94
1
Enhanced Options
1
SFF-8472
Compliance
F0
1.Optional Alarm/warning
flags implemented for all
monitored quantities
2.
Optional
Soft
TX_DISABLE control and
monitoring implemented
3. Optional Soft TX_FAULT
monitoring Implemented
4. Optional Soft RX_LOS
monitoring Implemented
01
Includes
functionality
described in Rev 9.3 of
SFF-8472.
95
1
CC_EXT
XX
CC for the extended ID Fields
(addresses
64
to
94)
implemented.
96~1
27
32
Vendor Specific
XX
Read only memory
128-2
55
128
Reserved
Read only
Note10: The “XX” byte should be filled in according to practical case. For more information, please refer to the
related document of SFP Multi-Source Agreement (MSA).
Recommend Circuit Schematic
Eoptolink Technology Inc., Ltd.
Page 15 of 17
V4.c
DWDM SFP Series
Mechanical Specifications
Obtaining Document
You can visit our website: http://www.eoptolink.com
Or contact Eoptolink Technology Inc., Ltd. Listed at the end of the documentation to get the latest
documents.
Revision History
Revision Initiated Reviewed Approved
Kelly.Cao
Revision History
Release
Date
Released.
Oct 24, 2009
V2.a
Tim.Liang
V2.b
Kelly
Revise the A2H.
Nov 24, 2009
V2.c
Kelly
Complete the DWDM
wavelength.
Jan 18, 2010
V2.d
Kelly
Correct Rx λ range.
Apr 8, 2010
V3.a
Kelly
Update PN&LOGO.
July 19, 2011
V3.b
Jans
Kelly
Update EEPROM
map, integrate 3
products.
Sep 21, 2011
V3.c
Jans
Kelly
Add 34Db products.
Dec 16, 2011
V3.d
Jans
Delete the product of
34Db budget.
Jan 6,2012
V3.e
Jans
Add OSNR/DNP.
Feb 27,2012
V3.f
Jans
Kelly
Update the
Eoptolink Technology Inc., Ltd.
Page 16 of 17
May 15
,2012
V4.c
DWDM SFP Series
Los-Assert of 29dB
budget.
V3.g
Kelly
Update note.
V3.h
Abby
Jason,
Kelly
V4.a
Jans
Jason,
Nygai
Update ICC and PW
Phlio
Oct 10, 2012
Dec 13, 2012
Add L band.
Mar 5, 2013
Sep 25,2013
October 17,
2013
V4.b
Angela
Lyn/Jason/
Walt/Nygai
Update regulatory
compliance, Tr/Tf and
the Pout of 17dB and
33dB products.
V4.c
Angela
Kelly/Jason
Correct the Max
receiver wavelength.
Notice:
Eoptolink reserves the right to make changes to or discontinue any optical link product or service
identified in this publication, without notice, in order to improve design and/or performance.
Applications that are described herein for any of the optical link products are for illustrative
purposes only. Eoptolink makes no representation or warranty that such applications will be
suitable for the specified use without further testing or modification.
Contact:
Add: Floor 5, Building 2, No. 21 Gaopeng Avenue, High-Tech District, CHENGDU, SICHUAN
610041 P.R. CHINA
Tel: (+86) 028-85122709 ext 816 & 809
Fax: (+86) 028-85121912
Postal: 610041
E-mail:[email protected]
http://www.eoptolink.com
Eoptolink Technology Inc., Ltd.
Page 17 of 17
V4.c