dopl“ky / accessories

Transkript

dopl“ky / accessories
KATALOG ¥99
DatovÈ a telekomunikaËnÌ rozvadÏËe
Data and Telecommunication Network Cabinets
V·ûenÌ z·kaznÌci,
Pr·vÏ se V·m dostal do rukou nov˝ katalog datov˝ch a telekomunikaËnÌch rozvadÏˢ ZERAK pro rok 1999. Naleznete zde nejen
p¯ehled rozvadÏˢ a doplÚk˘, kterÈ jiû zn·te, ale i ¯adu zajÌmav˝ch novinek. ServerovÈ aplikace rozvadÏˢ s maxim·lnÌ ventilacÌ za¯ÌzenÌ,
zv˝öenou ventilacÌ boËnÌch stÏn, zadnÌ stÏny, p¯ednÌch dve¯Ì atd. Katalog je doplnÏn zajÌmavou novinkou - mont·ûnÌm n·vodem,
kter˝ usnadnÌ sestavenÌ rozvadÏˢ a sk¯ÌnÌ dodan˝ch v rozloûenÈm stavu.
Douf·m, ûe V·m tento katalog pom˘ûe ve VaöÌ pr·ci, a ûe zde objevÌte mnoho nov˝ch a zajÌmav˝ch podnÏt˘ k VaöÌ plnÈ spokojenosti.
V p¯ÌpadÏ dotaz˘ je V·m plnÏ k dispozici naöe technickÈ Ëi obchodnÌ oddÏlenÌ.
DÏkuji V·m za Vaöi p¯ÌzeÚ a tÏöÌm se na dalöÌ spolupr·ci.
Dear customers,
This is a new catalogue of ZERAK data and telecommunication network cabinets for 1999. You will find here not only all the cabinets
and accessories that you are already familiar with but also many interesting new items. Among some of these novelties are server
network cabinet applications with maximum ventilation, increased side panel ventilation, new rear panel sections, and new front doors.
The catalogue also contains a useful novelty - a mounting design to help you assemble cabinets that are delivered in parts. I hope that
this catalogue will help you in your work and believe that it will provide you with many new and interesting ideas.
If you have any questions, please do not hesitate to contact our technical or marketing divisions. We will be more than happy to
assist you.
Thank you for your favour and I am looking forward to our future cooperation.
Jan Klanica
director
Obchodujte s n·mi
p¯es Internet
virtualnÌ obchodnÌ d˘m
www.meganet.cz
OBSAH / CONTENTS
Sk¯ÌnÏ n·stÏnnÈ / Wall-Mounted Cabinets
ZERAK 2000
Sk¯ÌnÏ na podlahu / Free-Standing Cabinets
ZERAK 3000
ZERAK 4000
ZERAK 8000
R·m sk¯ÌnÏ ZERAK / Frame of a ZERAK cabinet
VÌceËetnÈ sestavy sk¯ÌnÌ / Multiple cabinet combinations
StavebnÌ dÌly / Assembly Parts
Podesta / Stationary base/plinth
KoleËka / Castors
P¯ednÌ dve¯e / Front doors
BoËnÌ stÏny / Side panels
ZadnÌ stÏny / Rear panels
DoplÚujÌcÌ dÌl / Supplementary rear plate
HornÌ vÌka pro sk¯ÌnÏ na podlahu / Top covers for free-standing cabinets
HornÌ vÌka pro n·stÏnnÈ sk¯ÌnÏ / Top covers for free-standing cabinets
Dna r·mu / Base plates
⁄helnÌky k mont·ûi panel˘ / Panel/slide mounts for panel mounting
P¯ÌËky k mont·ûi ˙helnÌk˘ / Depth members for panel/slide mounts
RedukËnÌ liöty / Reduction mounts
DoplÚky / Accessories
Vertik·lnÌ vedenÌ kabel˘ / Vertical cable routing
Horizont·lnÌ vedenÌ kabel˘ / Horizontal cable routing
Panely s nava¯en˝mi h·Ëky / Panels with cable supports welded on
Panely s montovan˝mi h·Ëky / Panels with cable supports screwed on
Police / Support shelves
Police pro UPS / UPS support shelves
Drû·k police / Slide rails
Mont·ûnÌ sada / Assembly parts pack
ZaslepovacÌ panely / Blank filler panels
Patch-panely / Patch-panels
HrazdiËka / Cable support rail
⁄chyt perforovanÈ p¯ep·ûky / Cable support rail holder
Z·vÏsn˝ drû·k / Hinged 19î wall-mounted bracket
OsvÏtlovacÌ jednotka / Strip-light unit
Z·suvkov˝ systÈm do 19î / Socket strip
VentilaËnÌ jednotka umÌstÏn· v r·mu / Frame fan unit ZERAK 3000, 4000, 8000
VentilaËnÌ jednotka umÌstÏn· do vÌka / Frame fan unit ZERAK 2000
VentilaËnÌ jednotka do 19î / 19" fan unit
ZemnÌcÌ k·blÌky / Earthing cables
ZemnÌcÌ m˘stek pro / Earthing bridge for ZERAK 3000, 4000, 8000
Drû·k monitoru / Monitor box
OptickÈ rozvadÏËe / Fiber Optic Network Cabinets
Optick· sk¯ÌÚka mal· / Small-size fiber optic cabinet
Optick· sk¯ÌÚka velk·/ Big-size fiber optic cabinet
KonektorovÈ panely / Connector panels
19î police pro optiku / 19" shelves for fiber optic connectors
Projekty a obchodnÌ podmÌnky / Designs and Terms of Sale
VöeobecnÈ obchodnÌ podmÌnky / General Terms of Sale
ReklamaËnÌ podmÌnky / Complaint Procedure
N·vod mont·ûe / Assembly Manual
Projekt mont·ûe / Mounting Design
Pozn·mky k projektu / Design notes
strana 1
SKÿÕNÃ N¡STÃNN… / WALL-MOUNTED CABINETS ZERAK 2000
N·stÏnn· sk¯ÌÚ ZERAK 2000
Wall-Mounted Cabinet ZERAK 2000
Je urËena pro instalaci vyûadujÌcÌ snÌûenou v˝öku
horizont·lnÌch aplikacÌ. KoncepËnÏ vych·zÌ ze
sk¯ÌnÏ na podlahu ZERAK 3000. Z·kladnÌ zmÏna je
v provedenÌ boËnÌch stÏn sk¯ÌnÌ, kterÈ v sobÏ
spojujÌ nosnÈ p¯ÌËky pro uchycenÌ 19î nosnÌk˘
v jeden kompaktnÌ celek.
The wall-mounted cabinet ZERAK 2000 is intended
for installations that require a lowered height of
horizontal applications. Its conception is derived
from the free-standing cabinet ZERAK 3000. The
cardinal modification consists in the design of
the side panels of the cabinet: together with the
19" panel/slide mounts, they form a compact unit.
Jsou vyr·bÏny v pÏti z·kladnÌch v˝ök·ch :
4U, 6U, 9U, 12U, 15U
a ve dvojÌm provedenÌ :
a) nedÏlenÈ s hloubkou sk¯ÌnÏ 400 mm
b) dÏlenÈ s hloubkou sk¯ÌnÏ 500 mm
DÏlenÈ sk¯ÌnÏ jsou opat¯eny zadnÌm dÌlem 100 mm
hlubok˝m, kter˝ je s p¯ednÌ Ë·stÌ spojen dve¯nÌmi
z·vÏsy a z·mkem, coû umoûÚuje vstup do sk¯ÌnÏ
ze dvou stran. OtoËn˝ p¯ednÌ dÌl usnadÚuje mont·û
jakÈhokoliv za¯ÌzenÌ ve sk¯Ìni.
This cabinet is produced in five nominal heights:
4U, 6U, 9U, 12U, 15U
and two variations:
a) single section cabinet, depth 400 mm
b) double section cabinet, depth 500 mm
Both double section and single section cabinets
contain a rear part which has a depth of 100 mm.
This rear part is connected to the front part by
means of door hinges and a lock. These features
enable the user to enter the cabinet from two
directions. The swing front part makes it easy to
mount any equipment inside the cabinet.
Konstrukce sk¯ÌnÏ umoûÚuje plynule mÏnit aktivnÌ
hloubku sk¯ÌnÏ (podle rozmÏr˘ montovanÈho
za¯ÌzenÌ). Maxim·lnÌ hloubka instalovan˝ch za¯ÌzenÌ
je u jednodÌlnÈ sk¯ÌnÏ 360 mm a u dÏlenÈ sk¯ÌnÏ The construction of the cabinet makes it possible
460 mm. KrytÌ IP 30.
to change freely the disposable depth of the cabinet,
according to the dimensions of the installed
Sk¯ÌnÏ jsou opat¯eny dv̯ky se z·mkem, kterÈ equipment. The maximum depth available for the
mohou b˝t:
installed equipment is 360 mm for the single
a) kovovÈ
section cabinet and 460 mm for the double section
b) sklenÏnÈ (bezpeËnostnÌ, dvouvrstvÈ cabinet. The degree of protection is IP 30.
lepenÈ sklo barvy bronzovÈ)
The cabinet has a front door with a safety lock.
The door can be made of:
a) steel
b) glass (two layer security glass with
a bronze tint)
strana 2
SKÿÕNÃ N¡STÃNN… / WALL-MOUNTED CABINETS ZERAK 2000
JednotlivÈ dÌly sk¯ÌnÏ jsou opat¯eny konektory.
Jejich vz·jemn˝m propojenÌm pomocÌ zemnÌcÌch
k·blÌk˘ lze vytvo¯it vodivÈ spojenÌ vöech Ë·stÌ
sk¯ÌnÏ.
Individual sections of a cabinet are equipped with
connectors. Earthing cables can be fixed to these
connectors, hereby creating a conductive connection
of all sections of the cabinet.
Povrchov· ˙prava je provedena pr·ökov˝mi The surface texture of all ZERAK 2000 cabinets can
barvami RAL v odstÌnech:
be painted:
white
RAL 9003
bÌl·
RAL 9003
gray
RAL 7035
öed·
RAL 7035
black
RAL 9005
Ëern·
RAL 9005
(other colours are also possible upon the customerís
(na p¯·nÌ z·kaznÌka jsou moûnÈ i jinÈ odstÌny)
request)
Ke sk¯Ìni je dod·v·n bohat˝ sortiment doplÚk˘,
nap¯. police, zaslepovacÌ panely, patch-panely A wide assortment of accessories is supplied
with the cabinet, e.g. shelves, blank filler panels,
a dalöÌ, uvedenÈ v Ë·sti DOPL“KY.
patch panels, etc. For their complete list see the
ACCESSORIES section.
Informace k objedn·vce/Ordering Information:
prosklen· dv̯ka
Z·kladnÌ technickÈ ˙daje/Basic technical data:
velikost
v˝öka
size
plechov· dv̯ka
glazed door
steel door
4U jednodÌln·/single-section
19-04-SS1
19-04-SP1
4U dvoudÌln·/double-section
19-04-SS
19-04-SP
6U jednodÌln·/single-section
19-06-SS1
19-06-SP1
6U dvoudÌln·/double-section
19-06-SS
19-06-SP
9U jednodÌln·/single-section
19-09-SS1
19-09-SP1
9U dvoudÌln·/double-section
19-09-SS
19-09-SP
12U jednodÌln·/single-section
19-12-SS1
19-12-SP1
12U dvoudÌln·/double-section
19-12-SS
19-12-SP
15U jednodÌln·/single-section
19-15-SS1
19-15-SP1
15U dvoudÌln·/double-section
19-15-SS
19-15-SP
vnit¯nÌ vyuûiteln· v˝öka
ö̯ka
height inner disposable height width
hloubka
(mm,kg)
v·ha
depth
weight
4U jednodÌln·/single-section
252
178
600
400
17
4U dvoudÌln·/double-section
252
178
600
500
21
6U jednodÌln·/single-section
340
266
600
400
20
6U dvoudÌln·/double-section
340
266
600
500
24
9U jednodÌln·/single-section
474
400
600
400
23
9U dvoudÌln·/double-section
474
400
600
500
27
12U jednodÌln·/single-section
608
533
600
400
29
12U dvoudÌln·/double-section
608
533
600
500
33
15U jednodÌln·/single-section
740
666
600
400
30
15U dvoudÌln·/double-section
740
666
600
500
40
strana 3
SKÿÕNÃ NA PODLAHU / FREE-STANDING CABINETS
strana 4
SKÿÕNÃ NA PODLAHU / FREE-STANDING CABINETS ZERAK 3000
Sk¯ÌÚ na podlahu ZERAK 3000
Free Standing Cabinet ZERAK 3000
Je urËena nejen pro datovÈ, ale i pro telekomunikaËnÌ
rozvody a sv˝m designem se hodÌ jak do
kancel·¯skÈho prost¯edÌ, tak i do mÌstnostÌ se
za¯ÌzenÌm.
This cabinet is intended not only for data networks,
but also for telecommunication networks. Its
design makes it suitable for both office environment
and rooms with installations.
Jsou vyr·bÏny ve Ëty¯ech z·kladnÌch v˝ök·ch 17U, ZERAK 3000 is manufactured in four nominal
heights - 17U, 22U, 32U, and 42U. Its depth is
22U, 32U, 42U o hloubce 640 mm.
640 mm.
Konstrukce sk¯ÌnÏ umoûÚuje plynule mÏnit aktivnÌ
hloubku sk¯ÌnÏ posunem umÌstÏnÌ ˙helnÌk˘ The construction of the cabinet makes it possible
k mont·ûi panel˘. Pro rozs·hlejöÌ aplikace lze to change freely its disposable depth by shifting
sestavovat dvÏ Ëi vÌce sk¯ÌnÌ v jeden kompaktnÌ the placement of the panel/slide mounts. When
celek. Maxim·lnÌ hloubka instalovanÈho za¯ÌzenÌ used for larger applications, two or more cabinets
can be combined into a single compact unit. The
je 550 mm. KrytÌ IP 40.
maximum depth available for the installed equipment
Sk¯ÌnÏ jsou opat¯eny dve¯mi s klikou se z·mkem, is 550 mm. The degree of protection is IP 40.
kterÈ mohou b˝t:
The cabinets are equipped with a swivel handle
a) kovovÈ
b) sklenÏnÈ (bezpeËnostnÌ, dvouvrstvÈ and a safety lock. The door can be made of:
a) steel
lepenÈ sklo barvy bronzovÈ)
b) glass (two layer security glass with
a bronze tint)
Dve¯e jsou standardnÏ zavÏöeny vpravo, na p¯·nÌ
The door is normally hinged on right but it can
lze vöak jejich orientaci zmÏnit.
Sk¯ÌÚ m· demontovateln˝ bok a odnÌmatelnou also be hinged on left on request.
zadnÌ stÏnu se z·mky. Tato stÏna m˘ûe b˝t vcelku This cabinet has a side panel and a rear panel
nebo sestavena z pln˝ch zad a doplÚujÌcÌho dÌlu. with locks which can both be taken apart. The
rear panel can be in one unit or can be assembled
JednotlivÈ dÌly sk¯ÌnÏ jsou opat¯eny konektory. from a full rear plate and a supplementary panel.
Jejich vz·jemn˝m propojenÌm pomocÌ zemnÌcÌch
k·blÌk˘ lze vytvo¯it vodivÈ spojenÌ vöech Ë·stÌ Individual sections of a cabinet are equipped with
connectors. Earthing cables can be fixed to these
sk¯ÌnÏ.
connectors, hereby creating a conductive connection
Stavebnicov· konstrukce sk¯ÌnÏ umoûÚuje jejÌ of all sections of the cabinet.
˙plnÈ rozebr·nÌ na jednotlivÈ dÌly a tÌm i snadnou
manipulaci a p¯epravu.
The modular conception of the cabinetís construction
enables it to be completely taken apart into individual
Povrchov· ˙prava sk¯ÌnÌ je provedena pr·ökov˝mi segments and, consequently, it provides an easy
manipulation and transportation.
barvami RAL v odstÌnech:
bÌl·
RAL 9003
The surface texture of ZERAK 3000 cabinets can be
öed· RAL 7035
painted:
Ëern· RAL 9005
white
RAL 9003
(na p¯·nÌ z·kaznÌka jsou moûnÈ i jinÈ odstÌny)
gray
RAL 7035
black
RAL 9005
Nosnost sk¯ÌnÏ 42U je aû 500kg.
(other colours are also possible upon the customerís
Ke sk¯ÌnÌm se dod·v· bohat˝ sortiment doplÚk˘ request)
nap¯.: police, zaslepovacÌ panely, patch-panely
The load-carrying capacity of a 42U cabinet is up
a dalöÌ, uvedenÈ v Ë·sti DOPL“KY.
to 500 kg.
Z·kladnÌ sk¯ÌÚ obsahuje:
A wide assortment of accessories is supplied with
4x p¯ÌËka k mont·ûi ˙helnÌk˘
the cabinet, e.g. shelves, patch-panels, blank
2x r·m
filler panels, etc. For their complete list see
4x stojny tvo¯ÌcÌ kostru sk¯ÌnÏ
the ACCESSORIES section.
1x vÌko plnÈ
1x podesta komplet
Basic cabinet configuration:
Informace k objedn·vce/Ordering Information:
2x boËnÌ stÏna
4 depth members for panel/slide mounts
prosklen· dv̯ka
plechov· dv̯ka
1x dno 2/3 plnÈ
2 frames
glazed door
steel door
2x ˙helnÌk k mont·ûi panel˘
4 mounts that form the cabinetís
17U
19-17-PS
19-17-PP
1x zadnÌ stÏna (dle obj. jednoduch·
skeleton structure
22U
19-22-PS
19-22-PP
nebo dÏlen·)
1 top cover-plain
32U
19-32-PS
19-32-PP
1x p¯ednÌ dve¯e (dle obj. sklenÏnÈ nebo
1 stationary base/plinth
kovovÈ)
2 side panels
42U
19-42-PS
19-42-PP
1 base 2/3 size, plain
2 panel/slide mounts
1 rear panel (single-section or double-section,
Z·kladnÌ technickÈ ˙daje/Basic technical data:
(mm,kg)
according to a
velikost
v˝öka
vnit¯nÌ vyuûiteln· v˝öka
ö̯ka
hloubka
v·ha
customerís order)
size
height
inner disposable height
width
depth
weight
1 front door (glazed or made of steel,
17U
980
759
600
640
61
according to a customerís order)
22U
1202
981
600
640
32U
1646
1425
600
640
74
90
42U
2090
1869
600
640
105
strana 5
SKÿÕNÃ NA PODLAHU / FREE-STANDING CABINETS ZERAK 4000
Sk¯ÌÚ na podlahu ZERAK 4000
Free Standing Cabinets ZERAK 4000
Je urËena nejen pro datovÈ, ale i pro telekomunikaËnÌ
rozvody a sv˝m designem se hodÌ jak do kancel·¯skÈho
prost¯edÌ tak i do mÌstnostÌ se za¯ÌzenÌm. Sk¯ÌnÏ ¯ady
ZERAK 4000 jsou konstrukËnÏ totoûnÈ se sk¯ÌnÏmi
ZERAK 3000. LiöÌ se pouze hloubkou sk¯ÌnÏ (840 mm).
This cabinet is intended not only for data networks, but
also for telecommunication networks. Its design makes
it suitable for both office environment and rooms
with installations. Its construction is identical with
ZERAK 3000 cabinets, the only difference being the
depth of the cabinet (840 mm).
Vyr·bÌ se ve Ëty¯ech z·kladnÌch v˝ök·ch 17U, 22U,
32U, 42U o hloubce 840 mm.
Konstrukce sk¯ÌnÏ umoûÚuje plynule mÏnit aktivnÌ
hloubku sk¯ÌnÏ posunem umÌstÏnÌ ˙helnÌk˘ k mont·ûi
panel˘. Pro rozs·hlejöÌ aplikace lze sestavovat dvÏ Ëi
vÌce sk¯ÌnÌ v jeden kompaktnÌ celek. Maxim·lnÌ hloubka
instalovanÈho za¯ÌzenÌ je 750 mm. KrytÌ IP 40.
Sk¯ÌnÏ jsou opat¯eny dve¯mi s klikou se z·mkem, kterÈ
mohou b˝t:
a) kovovÈ
b) sklenÏnÈ (bezpeËnostnÌ, dvouvrstvÈ
lepenÈ sklo barvy bronzovÈ)
Dve¯e jsou standardnÏ zavÏöeny vpravo, na p¯·nÌ lze
vöak jejich orientaci zmÏnit.
Sk¯ÌÚ m· demontovateln˝ bok a odnÌmatelnou zadnÌ
stÏnu se z·mky. Tato stÏna m˘ûe b˝t vcelku nebo
sestavena z pln˝ch zad a doplÚujÌcÌho dÌlu.
JednotlivÈ dÌly sk¯ÌnÏ jsou opat¯eny konektory. Jejich
vz·jemn˝m propojenÌm pomocÌ zemnÌcÌch k·blÌk˘ lze
vytvo¯it vodivÈ spojenÌ vöech Ë·stÌ sk¯ÌnÏ.
Stavebnicov· konstrukce sk¯ÌnÏ umoûÚuje jejÌ ˙plnÈ
rozebr·nÌ na jednotlivÈ dÌly a tÌm i snadnou manipulaci
a p¯epravu.
Povrchov· ˙prava sk¯ÌnÌ je provedena pr·ökov˝mi
barvami RAL v odstÌnech:
bÌl·
RAL 9003
öed·
RAL 7035
Ëern· RAL 9005
(na p¯·nÌ z·kaznÌka jsou moûnÈ i jinÈ odstÌny)
Nosnost sk¯ÌnÏ 42U je aû 500 kg.
Ke sk¯ÌnÌm je dod·v·n bohat˝ sortiment doplÚk˘,
nap¯.: police, zaslepovacÌ panely, patch-panely a dalöÌ,
uvedenÈ v Ë·sti DOPL“KY.
Z·kladnÌ sk¯ÌÚ obsahuje:
4x p¯ÌËka k mont·ûi ˙helnÌk˘
2x r·m
4x stojny tvo¯ÌcÌ kostru sk¯ÌnÏ
1x vÌko plnÈ
1x podesta komplet
2x boËnÌ stÏna
1x dno 2/3 plnÈ
2x ˙helnÌk k mont·ûi panel˘
1x zadnÌ stÏna (dle obj. jednoduch·
nebo dÏlen·)
1x p¯ednÌ dve¯e (dle obj. sklenÏnÈ nebo
kovovÈ)
Informace k objedn·vce/Ordering Information:
prosklen· dv̯ka
strana 6
ZERAK 4000 is manufactured in four nominal heights 17U, 22U, 32U and 42U. Its depth is 840 mm.
The construction of the cabinet makes it possible to
change freely its disposable depth by shifting the
placement of the panel/slide mounts. When used for
larger applications, two or more cabinets can be
combined into a single compact unit. The maximum
depth available for the installed equipment is 750 mm.
The degree of protection is IP 40.
The cabinets are equipped with a swivel handle and
a safety lock. The door can be made of:
a) steel
b) glass (two layer security glass
with a bronze tint)
The door is normally hinged on right but it can also
be hinged on left on request. This cabinet has a side
panel with locks which can both be taken apart. The
rear panel can be in one unit or can be assembled
from a full rear plate and a supplementary panel.
Individual sections of a cabinet are equipped with
connectors. Earthing cables can be fixed to these
connectors, hereby creating a conductive connection
of all sections of the cabinet.
The modular conception of the cabinetís construction
enables it to be completely taken apart into individual
segments and, consequently, it provides an easy
manipulation and transportation.
The surface texture of ZERAK 4000 cabinets can be
painted:
white RAL 9003
gray
RAL 7035
black RAL 9005
(other colours are also possible upon the
customerís request)
The load-carrying capacity of a 42U cabinet is up to 500 kg.
A wide assortment of accessories is supplied with the
cabinet, e.g. shelves, blank filler panels, patch-panels,
etc. For their complete list see the ACCESSORIES section.
Basic cabinet configuration:
4 depth members for panel/slide
mounts
2 frames
4 mounts that form the cabinetís
skeleton structure
1 top cover-plain
1 stationary base/plinth
2 side panels
1 base 2/3 size, plain
2 panel/slide mounts
1 rear panel (single-section or
double-section, according to a
customerís order)
1 front door (glazed or made of steel,
according to a customerís order)
plechov· dv̯ka
Z·kladnÌ technickÈ ˙daje/Basic technical data:
velikost
v˝öka
vnit¯nÌ vyuûiteln· v˝öka
ö̯ka
hloubka
(mm,kg)
v·ha
glazed door
steel door
size
height
inner disposable height
width
depth
weight
17U
19-17-PS-80
19-17-PP-80
17U
980
759
600
840
101
22U
19-22-PS-80
19-22-PP-80
22U
1202
981
600
840
114
32U
19-32-PS-80
19-32-PP-80
32U
1646
1425
600
840
130
42U
19-42-PS-80
19-42-PP-80
42U
2090
1869
600
840
145
SKÿÕNÃ NA PODLAHU / FREE-STANDING CABINETS ZERAK 8000
Sk¯ÌÚ na podlahu ZERAK 8000
Free Standing Cabinets ZERAK 8000
Je urËena nejen pro datovÈ, ale i pro telekomunikaËnÌ
rozvody a sv˝m designem se hodÌ jak do kancel·¯skÈho
prost¯edÌ tak i do mÌstnostÌ se za¯ÌzenÌm.
ZERAK 8000 is designed not only for data networks,
but also for telecommunication networks. Its construction
makes it suitable for both office environment and rooms
with installations.
Sk¯ÌÚ ZERAK 8000 v˝öka 42U vych·zÌ rozmÏrovÏ ze
sk¯ÌnÏ 3000, jeho ö̯ka je vöak 800 mm. Sk¯ÌÚ je
moûno osadit vnit¯nÌmi redukËnÌmi liötami, kterÈ
redukujÌ jejÌ ö̯ku z 27ì na 19ì. P¯ednÌ dve¯e sk¯ÌnÏ
jsou opat¯eny dvÏmi klikami.
Konstrukce sk¯ÌnÏ umoûÚuje plynule mÏnit aktivnÌ
hloubku sk¯ÌnÏ posunem umÌstÏnÌ ˙helnÌk˘ k mont·ûi
panel˘. Pro rozs·hlejöÌ aplikace lze sestavovat dvÏ Ëi
vÌce v jeden kompaktnÌ celek. Maxim·lnÌ hloubka
instalovanÈho za¯ÌzenÌ je 550 mm. KrytÌ IP 40.
Sk¯ÌnÏ jsou opat¯eny dve¯mi s klikou se z·mkem, kterÈ
mohou b˝t:
a) kovovÈ
b) sklenÏnÈ (bezpeËnostnÌ, dvouvrstvÈ lepenÈ
sklo barvy bronzovÈ)
Dve¯e jsou standardnÏ zavÏöeny vpravo, na p¯·nÌ lze
vöak jejich orientaci zmÏnit.
Sk¯ÌÚ m· demontovateln˝ bok a odnÌmatelnou zadnÌ
stÏnu se z·mky (tato stÏna m˘ûe b˝t vcelku nebo
sestavena z pln˝ch zad a doplÚujÌcÌho dÌlu).
JednotlivÈ dÌly sk¯ÌnÏ jsou opat¯eny konektory. Jejich
vz·jemn˝m propojenÌm pomocÌ zemnÌcÌch k·blÌk˘ lze
vytvo¯it vodivÈ spojenÌ vöech Ë·stÌ sk¯ÌnÏ.
Stavebnicov· konstrukce sk¯ÌnÏ umoûÚuje jejÌ ˙plnÈ
rozebr·nÌ na jednotlivÈ dÌly a tÌm i snadnou manipulaci
a p¯epravu.
Povrchov· ˙prava sk¯ÌnÌ je provedena pr·ökov˝mi
barvami RAL v odstÌnech:
bÌl·
RAL 9003
öed·
RAL 7035
Ëern·
RAL 9005
(na p¯·nÌ z·kaznÌka jsou moûnÈ i jinÈ odstÌny)
Nosnost sk¯ÌnÏ 42U je aû 500 kg.
Ke sk¯ÌnÌm se dod·v· bohat˝ sortiment doplÚk˘, nap¯.:
police, zaslepovacÌ panely, patch-panely a dalöÌ,
uvedenÈ v Ë·sti DOPL“KY.
Z·kladnÌ sk¯ÌÚ obsahuje:
4x p¯ÌËka k mont·ûi ˙helnÌk˘
2x r·m
4x stojny tvo¯ÌcÌ kostru sk¯ÌnÏ
1x vÌko plnÈ
1x podesta komplet
2x boËnÌ stÏna
1x dno 2/3 plnÈ
2x ˙helnÌk k mont·ûi panel˘
1x zadnÌ stÏna (dle obj. jednoduch·
nebo dÏlen·)
1x p¯ednÌ dve¯e (dle obj. sklenÏnÈ nebo
kovovÈ)
Informace k objedn·vce/Ordering Information:
prosklen· dv̯ka
42U
plechov· dv̯ka
The dimensions of a 42U ZERAK 8000 cabinet are
derived from ZERAK 3000 with a modification of its
width to 800 mm. The cabinet can be equipped with
inner reduction mounts that reduce its width from 27î
to 19î. The front door of this cabinet has two handles.
The construction of the cabinet makes it possible
to change freely its disposable depth by shifting
the placement of the panel/slide mounts. When used
for larger applications, two or more cabinets can be
combined into a single compact unit. The maximum
depth available for the installed equipment is 550 mm.
The degree of protection is IP 40.
The cabinets are equipped with a swivel handle and
a safety lock. The door can be made of:
a) steel
b) glass (two layer security glass with
a bronze tint)
The door is normally hinged on right but it can also
be hinged on left on request.
This cabinet has a side panel and a rear panel with
locks which can both be taken apart. The rear panel
can be in one unit or can be assembled from a full
rear plate and a supplementary panel.
Individual sections of a cabinet are equipped with connectors. Earthing cables can be fixed to these
connectors, hereby creating a conductive connection
of all sections of the cabinet.
The modular conception of the cabinetís construction
enables it to be completely taken apart into individual
segments and, consequently, it provides an easy
manipulation and transportation.
The surface texture of ZERAK 3000 cabinets can be
painted:
white
RAL 9003
gray
RAL 7035
black
RAL 9005
(other colours are also possible upon the customerís
request)
The load-carrying capacity of a 42U cabinet is up to 500kg.
A wide assortment of accessories is supplied with the
cabinet, e.g. shelves, blank filler panels, patch-panels,
etc. For their complete list see the ACCESSORIES section.
Basic cabinet configuration:
4 depth members for panel/slide
mounts
2 frames
4 mounts that form the cabinetís
skeleton structure
1 top cover-plain
1 stationary base/plinth
2 side panels
1 base 2/3 size, plain
2 panel/slide mounts
1 rear panel (single-section or
double-section, according to a
customerís order)
1 front door (glazed or made of steel,
according to a customerís order)
Z·kladnÌ technickÈ ˙daje/Basic technical data:
velikost
v˝öka
vnit¯nÌ vyuûiteln· v˝öka
ö̯ka
hloubka
(mm,kg)
v·ha
glazed door
steel door
size
height
inner disposable height
width
depth
weight
27-42-PS
27-42-PP
42U
2090
1869
800
640
155
strana 7
SKÿÕNÃ NA PODLAHU / FREE-STANDING CABINETS
R·m sk¯ÌnÏ ZERAK
Frame of a ZERAK Cabinet
R·m sk¯ÌnÏ ZERAK je zkonstruov·n tak, aby byl plnÏ
variabilnÌ.
The ZERAK cabinet frame is constructed in a special
way to allow a complete variability.
Jeho z·klad tvo¯Ì Ëty¯i stojny navz·jem sestavenÈ
s hornÌm a dolnÌm dÌlem r·mu. Na tento z·kladnÌ
r·m je moûnÈ p¯id·vat dalöÌ dÌly dle specifikace
ze sortimentu p¯ÌsluöenstvÌ k vybudov·nÌ
systÈmu, kter˝ je optim·lnÌ pro Vaöi aplikaci r·mu.
The basis of the frame is made up of four mounts
that are connected with the top and bottom parts
of the frame. It is possible to fix additional
segments to this basic frame in order to create
a system that is ideal for your frame application.
Konstrukce umoûÚuje rozebr·nÌ na jednotlivÈ dÌly
a tÌm snazöÌ manipulaci a p¯epravu.
The construction of the frame enables it to
be taken apart into individual segments and,
consequently, it provides an easier manipulation
and transportation.
Povrchov· ˙prava r·mu je provedena pr·ökovou
barvou RAL v odstÌnu öed· 7035.
The surface texture of the frame is painted gray
RAL 7035.
strana 8
Informace k objedn·vce / Ordering Information:
r·m ZERAK 17U / frame of ZERAK cabinet 17U
RA-19-17
r·m ZERAK 22U / frame of ZERAK cabinet 22U
RA-19-22
r·m ZERAK 32U / frame of ZERAK cabinet 32U
RA-19-32
r·m ZERAK 42U / frame of ZERAK cabinet 42U
RA-19-42
SKÿÕNÃ NA PODLAHU / FREE-STANDING CABINETS
VÌceËetnÈ sestavy sk¯ÌnÌ
Multiple Cabinet Combinations
Stavebnicov· konstrukce sk¯ÌnÏ umoûÚuje pro The modular conception of the cabinetís construction
speci·lnÌ ˙Ëely spojenÌ dvou Ëi vÌce sk¯ÌnÌ v jeden enables a combination of two or more cabinets
kompaktnÌ celek.
into a single compact unit for special purposes.
Z·kladnÌ provedenÌ r·mu je totoûnÈ s jednoduchou
sk¯ÌnÌ.
PouûitÌm spojovacÌch öroub˘ a spojovacÌho dÌlu
podesty je moûno sestavit poûadovan˝ poËet
sk¯ÌnÌ.
The basic conceptual possibility of the frame is
identical with the basic form of the cabinet.
It is possible to assemble the required number of
cabinets by using connecting screws and the
connecting stationary base/plinth member.
K sestavenÌ dvou sk¯ÌnÌ v jednu je t¯eba:
spojovacÌ dÌl pro dvÏ podesty v jednu 2ks
spojovacÌ örouby
4ks
For the assembly of a double cabinet unit by
using two cabinets, the following accessories are
necessary:
connecting segment to make
two stationary bases into one
2 pieces
connecting screws
4 pieces
Informace k objedn·vce/Ordering Information:
spojovacÌ dÌl pro dvÏ podesty
connecting segment to make two stationary bases into one
spojovacÌ öroub
connecting screw
Detail spojenÌ dvou
sk¯ÌnÌ pomocÌ öroub˘
k sestavenÌ sk¯ÌnÌ
v jeden celek.
PO-04-SD
SR-01-01
A detailed view of a unit
made of two cabinets
connected with
connecting screws.
strana 9
STAVEBNÕ DÕLY / ASSEMBLY PARTS
Podesta
Stationary Base/Plinth
Sestaven· podesta se skl·d· z:
2x boËnÌ dÌl podesty s rohy
1x spojovacÌ dÌl pln˝
1x spojovacÌ dÌl s otvorem
Tyto spojovacÌ dÌly podesty jsou dod·v·ny ve
Ëty¯ech provedenÌch:
a) spojovacÌ dÌl pln˝
b) spojovacÌ dÌl s otvorem
c) spojovacÌ dÌl se zaslepen˝m otvorem
d) spojovacÌ dÌl s vÏtracÌmi otvory
p¯iËemû je moûn· jejich libovoln· kombinace.
Pro vÌceËetnÈ sestavy sk¯ÌnÌ dod·v·me
netypizovanÈ podesty sloûenÈ z boËnÌch dÌl˘
s rohy a p¯ÌsluönÈho poËtu spojovacÌch dÌl˘,
fixovan˝ch speci·lnÌmi ìspojovacÌmi dÌly pro dvÏ
podesty v jednuî.
Z·kladnÌ v˝öka podesty je 100 mm. Tuto v˝öku lze
zdvoj Ëi ztrojn·sobit mont·ûÌ jednotliv˝ch podest
na sebe. Vöechny typy se mohou namontovat
i pootoËenÈ o 90 stupÚ˘.
Povrchov· ˙prava je provedena pr·ökovou barvou
RAL v odstÌnu öed· 7035 .
The assembled stationary base/plinth consists
of:
2 side segments with corners
1 connecting segment, unperforated
1 connecting segment, with a hole
The connecting base segments are manufactured
and made available in four variations:
a) connecting segment with a uniform
panel (unperforated)
b) connecting segment with a hole
c) connecting segment with a blinded
hole
d) connecting segment with ventilation
perforations - louvres
Any desired combination of these connecting
segments is possible.
For multiple cabinet combinations, we supply
special stationary bases/plinths assembled from
side segments with corners and an appropriate
number of connecting segments joined by means
of special "connecting segments to make two
stationary bases into one".
The basic height of the stationary base/plinth is
100 mm. This height can be doubled or tripled by
mounting individual bases/plinths on top of one
another. All types can be mounted even in a 90∞
angle.
The surface texture of the stationary base/plinth
is painted gray RAL 7035.
Informace k objedn·vce / Ordering Information:
podesta jednoduch· sestaven· / single stationary base/plinth, assembled
PO-10-1P
podesta dvojit· sestaven· / double stationary base/plinth, assembled
PO-10-2P
boËnÌ dÌl podesty s rohy pro/ side segment with corners for
ZERAK 3000, 8000
PO-10-RP
boËnÌ dÌl podesty s rohy pro / side segment with corners fo
ZERAK 4000
PO-20-RP
spojovacÌ dÌl podesty pln˝ pro / connecting segment with a uniform panel (unperforated) for
ZERAK 3000, 4000
PO-01-SD
spojovacÌ dÌl podesty s otvorem pro / connecting segment with a hole for
ZERAK 3000, 4000
PO-02-SD
spojovacÌ dÌl podesty s vÏtracÌmi otvory pro / connecting segment with ventilation perforations for
ZERAK 3000, 4000
spojovacÌ dÌl pro dvÏ podesty / connecting segment to make two stationary bases
strana 10
PO-03-SD
PO-04-SD
spojovacÌ dÌl podesty se zasl. otvorem pro / connecting segment with a blinded hole for
ZERAK 3000, 4000
PO-05-SD
spojovacÌ dÌl podesty pln˝ pro / connecting segment with a uniform panel (unperforated) for
ZERAK 8000
PO-06-SD
spojovacÌ dÌl podesty s otvorem pro / connecting segment with a hole for
ZERAK 8000
PO-07-SD
spojovacÌ dÌl podesty s vÏtracÌmi otvory pro / connecting segment with ventilation perforations for
ZERAK 8000
PO-08-SD
spojovacÌ dÌl podesty se zals. otvorem pro / connecting segment with a blinded hole for
ZERAK 8000
PO-09-SD
STAVEBNÕ DÕLY / ASSEMBLY PARTS
KoleËka
Castors
Pro lepöÌ manipulaci jsou ke sk¯ÌnÌm dod·v·ny
pojezdov· otoËn· koleËka. P¯i pouûitÌ koleËek
se znaËnÏ sniûuje nosnost sk¯ÌnÏ. KoleËka se
montujÌ k podestÏ.
Cabinets can be supplied with castors, i.e. small
rotating wheels, that make the cabinets easy to
move. When castors are used, the load-carrying
capacity of a cabinet is considerably reduced.
The castors are mounted to the stationary
base/plinth.
KoleËka jsou dod·v·ny ve dvojÌm provedenÌ:
otoËnÈ koleËko v ocelovÈm r·mu
otoËnÈ koleËko v ocelovÈm r·mu s aretacÌ
Castors can be supplied in two modifications:
standard castors in steel casing
lockable castors in steel casing
Informace k objedn·vce / Ordering Information:
otoËnÈ koleËko / standard castor
PO-01-KP
otoËnÈ koleËko s aretacÌ / lockable castor
PO-02-KP
Schema mont·ûe / Castor mounting design
strana 11
STAVEBNÕ DÕLY / ASSEMBLY PARTS
P¯ednÌ dve¯e
Front Door
Ke sk¯ÌnÌm ZERAK jsou dod·v·ny p¯ednÌ dve¯e
v provedenÌ se sklem nebo kovovÈ, kompletnÌ
s upevÚovacÌmi prvky a z·mkem. ProsklenÈ dve¯e
jsou osazeny bezpeËnostnÌm dvouvrstv˝m sklem
barvy bronzovÈ.
K serverov˝m aplikacÌm dod·v·me speci·lnÌ
prosklenÈ dve¯e s vÏtracÌmi otvory.
ZERAK cabinets are equipped with front doors either glazed (and framed) or steel ones. The
doors are complete, they are supplied with
DIRAK hinges, assembly parts and a lock. The
glazed door uses two layer security glass with
a bronze tint.
Special glass door with ventilation perforations
are supplied for server applications.
Povrchov· ˙prava kovov˝ch dÌl˘ je provedena
pr·ökovou barvou RAL v odstÌnu bÌl· 9003.
Informace k objedn·vce / Ordering Information:
The surface texture of the metal parts is painted
white RAL 9003.
Informace k objedn·vce / Ordering Information:
sklo lepenÈ t¯ÌötivÈ, bronz
4U
two layer security glass, bronze tint
DV-01-4
4U
steel door
DV-02-4
DV-02-6
6U
DV-01-6
6U
9U
DV-01-9
9U
DV-02-9
12U
DV-01-12
12U
DV-02-12
15U
DV-01-15
15U
DV-02-15
17U
DV-01-17
17U
DV-02-17
22U
DV-01-22
22U
DV-02-22
prosklenÈ dve¯e s vÏtracÌmi otvory - serverov· aplikace
32U
DV-01-32
32U
DV-02-32
42U
DV-01-42
42U
glass door with ventilation perforations
32U
DV-03-32
42U
DV-03-42
42U, ö̯ka 800 mm / width 800 mm DV-01-42-80
strana 12
kovovÈ dve¯e
42U, ö̯ka 800 mm / width 800 mm
DV-02-42
DV-02-42-80
Informace k objedn·vce / Ordering Information:
STAVEBNÕ DÕLY / ASSEMBLY PARTS
Detail p¯ipevnÏnÌ boËnÌ
a zadnÌ stÏny.
A detailed view of the way
the side and rear panels
are connected.
BoËnÌ stÏny
Side Panels
BoËnÌ stÏny jsou v r·mu upevnÏny pomocÌ
öroubovÈho spoje a jsou odnÌmatelnÈ.
Ke sk¯ÌnÌm ZERAK jsou dod·v·ny boËnÌ stÏny ve
trojÌm provedenÌ:
a) boËnÌ stÏna odnÌmateln·, upevnÏn· pomocÌ
öroubovÈho spoje (standardnÏ dod·van·)
b)boËnÌ rychle odnÌmateln· stÏna upevnÏn·
pomocÌ z·padek a z·mku (usnadÚujÌ vstup
do sk¯ÌnÏ k instalovanÈmu za¯ÌzenÌ,
odpad· rozebÌr·nÌ öroubov˝ch spoj˘)
c) boËnÌ stÏna s vÏtracÌmi otvory
(ZERAK 3000, 4000, 8000)
Povrchov· ˙prava je provedena pr·ökovou barvou
RAL v odstÌnu bÌl· 9003.
The side panels are fixed inside the frame by
means of connecting screws. The panels can be
taken down.
ZERAK cabinets are supplied with side panels in
three variations:
a) a replaceable side panel, secured with screws
this is the supplied standard
b) a replaceable side panel, secured with fixing
and a lock (this makes the access to the
installed equipment inside the cabinet
easier by avoiding the necessity to
unscrew the side panel)
c) Side panel with ventilation perforations
(for Zerak 3000, 4000, 8000)
The surface texture of the side panels is painted
white RAL 9003.
Informace k objedn·vce / Ordering Information:
ZERAK 3000/8000
ZERAK 4000
boËnÌ stÏna / side panel 17U
BK-01-17
BK-80-17
boËnÌ stÏna / side panel 22U
BK-01-22
BK-80-22
boËnÌ stÏna / side panel 32U
BK-01-32
BK-80-32
boËnÌ stÏna / side panel 42U
BK-01-42
BK-80-42
boËnÌ stÏna se z·mkem / side panel with a lock 17U
BK-02-17
BK-81-17
boËnÌ stÏna se z·mkem / side panel with a lock 22U
BK-02-22
BK-81-22
boËnÌ stÏna se z·mkem / side panel with a lock 32U
BK-02-32
BK-81-32
boËnÌ stÏna se z·mkem / side panel with a lock 42U
BK-02-42
BK-81-42
Detail uchycenÌ boËnÌ
stÏny se z·mkem.
A detailed view of the way
the side panel is fixed with
a lock
Informace k objedn·vce / Ordering Information:
ZERAK 3000/8000
ZERAK 4000
boËnÌ stÏna s vÏtracÌmi otvory / side panel with ventilation perforations 17U
BK-03-17
BK-82-17
boËnÌ stÏna s vÏtracÌmi otvory / side panel with ventilation perforations 22U
BK-03-22
BK-82-22
boËnÌ stÏna s vÏtracÌmi otvory / side panel with ventilation perforations 32U
BK-03-32
BK-82-32
boËnÌ stÏna s vÏtracÌmi otvory / side panel with ventilation perforations 42U
BK-03-42
BK-82-42
strana 13
STAVEBNÕ DÕLY / ASSEMBLY PARTS
ZadnÌ stÏny
Rear Panels
ZadnÌ stÏny sk¯ÌnÌ ZERAK jsou vyr·bÏny a dod·v·ny
v pÏti provedenÌch:
a) plechovÈ celÈ
b) plechovÈ dÏlenÈ (dÏlenÈ na dvÏ Ë·sti pro sk¯ÌnÏ
o v˝ök·ch 32U a 42U)
c) plechovÈ celÈ s vÏtracÌmi otvory a s otvorem
pro vstup k za¯ÌzenÌm
d) plechovÈ celÈ s vÏtracÌmi otvory
e) plechovÈ celÈ s vÏtracÌmi otvory - serverov·
aplikace
The rear panels of ZERAK cabinets are manufactured
and made available in five variations:
a) full-size metal plate
b) divided metal plate (divided into two parts for
cabinets with the height of 32U and 42U)
c) a full-size metal panel with ventilation perforations
and a hole enabling access to the mounted
equipment
d) a full-size metal panel with ventilation perforations
e) a full-size metal panel with ventilation perforations
a server application
ZadnÌ stÏna je k r·mu uchycena z·mky a je
snadno odnÌmateln·. Je vyr·bÏna kompletnÌ
s vymezovacÌmi konzolami a upevÚovacÌmi prvky.
DÏlen· zadnÌ stÏna se skl·d· ze zadnÌ stÏny
a z doplÚujÌcÌho dÌlu.
DoplÚujÌcÌ dÌl se vyr·bÌ o v˝öce 10U a p¯i mont·ûi
dÏlenÈ zadnÌ stÏny je kombinov·n se stÏnami
o v˝ök·ch 32U a 22U.
Povrchov· ˙prava je provedena pr·ökovou barvou
RAL v odstÌnu bÌl· 9003.
The rear part is connected to the frame with locks
and is easy to take apart. It is manufactured in
a complete form with fixing members and
assembly parts.
The divided rear panel consists of a rear panel
and a supplementary rear plate.
The height of the supplementary rear plate is
10U. When a divided rear panel is being mounted,
this supplementary rear plate combines with
32U and 22U rear panels.
The surface texture of the rear panel is painted
white RAL 9003.
Informace k objedn·vce / Ordering Information:
zadnÌ stÏna plechov· pln· s vÏtracÌmi otvory s otvorem pro vstup k za¯ÌzenÌm
a full-size metal rear panel with ventilation perforations and a hole enabling access to the mounted equipment
42U
DZ-02-42
Informace k objedn·vce / Ordering Information:
zadnÌ stÏna plechov·
metal rear panel
strana 14
pln·
s vÏtracÌmi otvory
s vÏtracÌmi otvory - serverov· aplikace
unperforated
with ventilation perforations
with ventilation perforations - a server application
12U pouûitÌ u zadnÌ dÏlenÈ stÏny pro rozvadÏËe na podlahu
DZ-01-12
-
-
17U
DZ-01-17
DZ-03-17
-
22U
DZ-01-22
DZ-03-22
-
32U
DZ-01-32
DZ-03-32
DZ-04-32
42U
DZ-01-42
DZ-03-42
DZ-04-42
17U ö̯ka 800 mm / width 800 mm
DZ-80-17
-
-
22U ö̯ka 800 mm / width 800 mm
DZ-80-22
-
-
32U ö̯ka 800 mm / width 800 mm
DZ-80-32
-
-
42U ö̯ka 800 mm / width 800 mm
DZ-80-42
-
-
STAVEBNÕ DÕLY / ASSEMBLY PARTS
DoplÚujÌcÌ dÌl
Supplementary Rear Plate
DoplÚujÌcÌ dÌl je vyr·bÏn o v˝öce 10U a p¯i mont·ûi
dÏlenÈ zadnÌ stÏny je kombinov·n se stÏnami
o v˝ök·ch 32U a 22U.
DoplÚujÌcÌ dÌl zadnÌ stÏny je vyr·bÏn ve t¯ech
provedenÌch:
a) pln˝ bez otvor˘
b) s otvorem pro p¯Ìvod kabel˘
c) dÏrovan˝ vÏtracÌ
The supplementary rear plate is 10U high and is
intended to be combined with either a 32U rear
panel or a 22U rear panel.
The supplementary rear plate for the rear panel is
manufactured in three variations:
a) plain plate without any holes
b) with a cut-out for cable entry
c) with perforations for ventilation
DoplÚujÌcÌ dÌl zadnÌ stÏny se montuje pod nebo
nad zadnÌ stÏnu. Je uchycen öroubov˝m spojem
k r·mu a je demontovateln˝.
Povrchov· ˙prava je provedena pr·ökovou barvou
RAL v odstÌnu bÌl· 9003.
The supplementary rear plate is mounted either
above or below the main rear panel. It is fixed with
a connecting screw to the frame and can be taken
apart, if necessary.
The surface texture of the supplementary rear
plate is painted white RAL 9003.
Informace k objedn·vce / Ordering Information:
plechov˝ doplÚ. dÌl pln˝ / supplementary metal rear plate - unperforated
DZ-02-10
plechov˝ doplÚ. dÌl s otvorem / supplementary metal rear plate - with a cut-out
DZ-03-10
plechov˝ doplÚ. dÌl s vÏtrac. otvory / supplementary metal rear plate - with ventilation perforations DZ-04-10
strana 15
STAVEBNÕ DÕLY / ASSEMBLY PARTS
HornÌ vÌka pro sk¯ÌnÏ na podlahu
Top Covers for Free-standing Cabinets
HornÌ vÌka ke sk¯ÌnÌm ZERAK 3000, 4000 a 8000
jsou vyr·bÏna a dod·v·na ve dvou provedenÌch:
a) hornÌ vÌko plnÈ
b) hornÌ vÌko s vÏtracÌmi otvory
The top covers for ZERAK 3000, 4000, 8000 cabinets
are manufactured and made available in two
variations:
a) plain top cover
b) top cover with perforations for
ventilation
HornÌ vÌko je k r·mu p¯ipevnÏno öroubov˝m spojem.
DÏrovanÈ hornÌ vÌko usnadÚuje obÏh vzduchu ve
sk¯Ìni.
Kombinace dÏrovanÈho vÌka a chladÌcÌ jednotky
podstatnÏ zlepöuje teplotnÌ podmÌnky ve sk¯Ìni
dÌky nucenÈmu obÏhu vzduchu.
Povrchov· ˙prava je provedena pr·ökovou barvou
RAL v odstÌnu bÌl· 9003.
The top cover is fixed to the frame with connecting
screws. The perforated top cover facilitates the
air circulation inside the cabinet. The combination
of a perforated top cover and a cooler/ventilation
unit significantly improves the temperature
conditions inside the cabinets thanks to
an induced air circulation inside.
The surface texture of the top cover is painted
white RAL 9003.
Informace k objedn·vce / Ordering Information:
ZERAK 3000
ZERAK 4000
ZERAK 8000
plnÈ / plain
HK-01-PL
HK-03-PL
HK-05-PL
s vÏtracÌmi otvory /
with perforations for ventilation
HK-02-VO
HK-04-VO
HK-06-VO
HornÌ vÌka pro n·stÏnnÈ sk¯ÌnÏ
Top Covers for Wall-mounted Cabinets
HornÌ vÌka pro ZERAK 2000 jsou vyr·bÏna ve t¯ech
provedenÌch:
a) hornÌ vÌko plnÈ
b) hornÌ vÌko s otvorem
c) hornÌ vÌko s otvorem a vÏtracÌmi otvory
HornÌ vÌko s otvorem umoûÚuje vstup kabel˘ nejen
u dÏlen˝ch rozvadÏˢ.
Povrchov· ˙prava je provedena pr·ökovou barvou
RAL v odstÌnu bÌl· 9003.
The top covers for ZERAK 2000 are supplied in three
variations:
a) plain top cover (unperforated)
b) top cover with a cut-out for cable entry
c) top cover with a cut-out and ventilation
perforations
Top cover with a hole enabling cable entry into
single - section cabinets.
The surface texture of the top coveris painted white
RAL 9003.
Informace k objedn·vce / Ordering Information:
strana 16
plnÈ / plain
HK-07-PL
s otvorem / with a cut-out for cable entry
HK-04-OT
s otvorem a vÏtracÌmi otvory / with a cut-out and ventilation perforations
HK-05-VO
STAVEBNÕ DÕLY / ASSEMBLY PARTS
Dna r·mu
Base Plate
SpodnÌ Ë·st sk¯ÌnÏ je opat¯ena dnem, kterÈ m˘ûe
r·m zaslepit ˙plnÏ nebo jen zË·sti. Velikost otvoru
je ovlivnÏna pouze mnoûstvÌm vstupujÌcÌch kabel˘.
K mont·ûi jsou dod·v·na dna v tÏchto
provedenÌch:
a) dno plnÈ - r·m plnÏ zaslepen˝
b) dno 2/3 - r·m je zaslepen ze 2/3
c) dno 1/3 - r·m je zaslepen z 1/3
The bottom part of the cabinet is equipped with
a base plate that can either completely or partially
cover the frame. The size of the hole depends
only on the number of cables entering the cabinet
through this bottom part.
The base plates are available for mounting in the
following variations:
a) full-size base plate (plain) - the frame is
completely covered
JednotlivÈ typy dna se dajÌ navz·jem kombinovat, b) two-third size base plate - the frame is
nap¯Ìklad:
covered in two thirds
dno 1/3+1/3 = 2/3
c) one-third size base plate - the frame is
dno 2/3+1/3 = celÈ
covered in one third
dno 1/3+1/3 +1/3 = celÈ
The individual types of base plates can be mutually
Vöechny typy lze namontovat i pootoËenÈ o 90 combined with one another to form various
stupÚ˘. Na zvl·ötnÌ objedn·vku je moûno vyrobit combinations, e.g.:
i 2/3, nebo 1/3 dno s V·mi navrûen˝mi otvory.
one third + one third base plates = two thirds
two third + one third base plates = full space
Sk¯ÌnÏ ZERAK 4000 a 8000 majÌ vÏtöÌ vnit¯nÌ prostor
one third + one third + one third base
plates = full space
a proto k nim dod·v·me doplnÏk krytu dna, kter˝
slouûÌ i k zaslepenÌ vzniklÈho prostoru v r·mu za
ventilaËnÌ jednotkou.
All types of base plates can be mounted in a 90∞
angle. Upon a special order, it is possible to
Povrchov· ˙prava je provedena pr·ökovou barvou manufacture two-third size or one-third size
base plates with specific perforations to fit your
RAL v odstÌnu öed· 7035.
special need.
ZERAK 4000 and 8000 cabinets have bigger inner
dimensions . We therefore supply a supplementary
base plate to cover both the extra base dimension
and the space
The surface texture of the base plates is painted
gray RAL 7035.
Informace k objedn·vce / Ordering Information:
Detail pouûitÌ doplÚku krytu dna u rozvadÏËe ZERAK 4000
A detailed view of the base plate cover supplement for Zerak 4000
dno r·mu plnÈ / full-size base plate (plain)
DP-01
dno r·mu 2/3 plnÈ / two-third size base plate
DP-02
dno r·mu 1/3 plnÈ / one-third size base plate
DP-03
doplnÏk krytu dna / extension base plate
DP-04
Detail pouûitÌ 2/3 dna do rozvadÏËe ZERAK 3000
A detailed view of the two-third size base plate for Zerak 3000
strana 17
STAVEBNÕ DÕLY / ASSEMBLY PARTS
⁄helnÌky k mont·ûi panel˘
Panel/Slide Mounts for Panel Mounting
Tyto ˙helnÌky jsou vyr·bÏny a dod·v·ny v p·rech.
UchycenÌm na p¯ÌËku je umoûnÏna jejich mont·û
v libovolnÈ hloubce sk¯ÌnÏ. Vz·jemn· vzd·lenost
˙helnÌk˘ je standardnÏ 19".
Jsou vyr·bÏny a dod·v·ny pro vöechny typy
sk¯ÌnÌ n·stÏnn˝ch a sk¯ÌnÌ na podlahu ZERAK.
Povrchov· ˙prava je provedena pr·ökovou
barvou RAL v odstÌnu Ëern· 9005.
Na p¯·nÌ je moûnÈ galvanickÈ pokovenÌ zinkem.
These panel/slide mounts are manufactured and
supplied in pairs. By mounting them on depth
members, you can place them in any depth inside
the cabinet. The distance between the panel/slide
mounts is the 19" standard. They are manufactured
and supplied for all types of wall-mounted and
free-standing ZERAK cabinets.
The surface texture of the panel/slide mounts is
painted black RAL 9005.
Upon a customerís request, the panel/slide
mounts can be zinc-plated by galvanization.
Informace k objedn·vce / Ordering Information:
˙helnÌk / panel/slide mount
ZERAK 2000 - 4U
UN-02-04
UNZ-02-04
˙helnÌk / panel/slide mount
ZERAK 2000 - 6U
UN-02-06
UNZ-02-06
˙helnÌk / panel/slide mount
ZERAK 2000 - 9U
UN-02-09
UNZ-02-09
˙helnÌk / panel/slide mount
ZERAK 2000 - 12U
UN-02-12
UNZ-02-12
˙helnÌk / panel/slide mount
ZERAK 2000 - 15U
UN-02-15
UNZ-02-15
˙helnÌk / panel/slide mount
ZERAK 3000, 4000, 8000 - 17U
UN-02-17
UNZ-02-17
˙helnÌk / panel/slide mount
ZERAK 3000, 4000, 8000 - 22U
UN-02-22
UNZ-02-22
˙helnÌk / panel/slide mount
ZERAK 3000, 4000, 8000 - 32U
UN-02-32
UNZ-02-32
˙helnÌk / panel/slide mount
ZERAK 3000, 4000, 8000 - 42U
UN-02-42
UNZ-02-42
UN - ˙helnÌk Ëern˝ / black colour
UNZ - ˙helnÌk pokoven˝ (zinek) / zinc-plated
P¯ÌËky k mont·ûi ˙helnÌk˘
P¯ÌËky k mont·ûi ˙helnÌk˘ jsou dod·v·ny jako
souË·st plnÏ smontovanÈ sk¯ÌnÏ ZERAK a jsou
k r·mu sk¯ÌnÏ p¯ipevnÏny öroubov˝m spojem.
UmoûÚujÌ plynulÈ nastavenÌ hloubky ˙helnÌk˘.
Povrchov· ˙prava je provedena pr·ökovou
barvou RAL v odstÌnu Ëern· 9005.
strana 18
Depth Members for Mounting
Panel/Slide Mounts
The depth members for mounting panel/slide
mounts are supplied as a part of a fully assembled
ZERAK cabinet. They are fixed to the frame of the
cabinet with connecting screws. They enable
continual depth placement of panel/slide mounts.
The surface texture of the depth members is
painted black RAL 9005.
Informace k objedn·vce / Ordering Information:
p¯ÌËka k mont·ûi ˙helnÌk˘ pro ZERAK 3000, 8000 / depth member for ZERAK 3000, 8000
PM-01-U
p¯ÌËka k mont·ûi ˙helnÌk˘ pro ZERAK 4000/ depth member for ZERAK 4000
PM-02-U
STAVEBNÕ DÕLY / ASSEMBLY PARTS
Detail uchycenÌ ˙helnÌk˘ k p¯ÌËce
Detail of Panel/Slide Mounts Mounted
UchycenÌ je provedeno öroubov˝m spojem. on Depth Members
Konstrukce umoûÚuje plynulÈ nastavenÌ ˙helnÌk˘ The mounting is secured with connecting screws.
po celÈ hloubce sk¯ÌnÏ.
The construction allows a continual placement
of panel/slide mounts along the entire depth
of the cabinet.
RedukËnÌ liöty
Reduction Mount
Pro umÌstÏnÌ 19î za¯ÌzenÌ do 27î sk¯ÌnÏ The reduction mount from 27î to 19î enables the
placement of 19î equipment into a 27î ZERAK 8000
ZERAK 8000 slouûÌ redukËnÌ liöta 27î-19î.
cabinet.
Informace k objedn·vce / Ordering Information:
redukËnÌ liöta 27î - 19î/ reduction mount from 27î - 19î
RL-01-42
strana 19
DOPL“KY / ACCESSORIES
Vertik·lnÌ vedenÌ kabel˘
Vertical Cable Routing
je ¯eöeno montovateln˝mi h·Ëky, kterÈ jsou
vyr·bÏny a dod·v·ny ve t¯ech rozmÏrech:
h·Ëek 1x1U
h·Ëek 1x2U
h·Ëek 2x2U
Pro vertik·lnÌ vedenÌ kabelu se jednotlivÈ h·Ëky
p¯ichycujÌ na ˙helnÌky k mont·ûi panel˘.
Povrchov· ˙prava je provedena potaûenÌm
plastem ËernÈ barvy.
Vertical cable routing is made possible by cable
supports that can be mounted with connecting
screws. The cable supports are manufactured
and supplied in three dimensions:
cable support 1 x 1U
cable support 1 x 2U
cable support 2 x 2U
Individual cable supports are mounted on
panel/slide mounts for neat vertical routing of
cable bundles.
The cable supports are covered with black plastic
coating.
Informace k objedn·vce / Ordering Information:
h·Ëek 1x1U / cable support 1x1U
VV-01-H
h·Ëek 1x2U / cable support 1x2U
VV-02-H
h·Ëek 2x2U / cable support 2x2U
VV-03-H
Horizont·lnÌ vedenÌ kabel˘
Horizontal Cable Routing
Pro horizont·lnÌ vedenÌ kabelu se pouûÌvajÌ panely
o velikosti 1U a 2U, na kterÈ jsou jednotlivÈ h·Ëky
p¯ichyceny pevn˝m spojenÌm - sva¯enÌm nebo
rozebÌrateln˝m - öroubov˝m spojem.
Horizontal cable routing is made possible by
panels size 1U and 2U, to which the individual
cable supports are mounted in a fixed manner either by welding or by screwing on. The connecting
screws enable the cable supports to be taken
apart at your will.
Panely s nava¯en˝mi h·Ëky
Panels with Cable Supports Welded on
Panely jsou dod·v·ny ve dvou velikostech
1U a 2U, p¯iËemû na panel 1U mohou b˝t nava¯eny
h·Ëky 1x1U aû 5 ks nebo 1x2U aû 5 ks. Na panel
2U pouze h·Ëky 2x2U aû 5 ks. StandardnÌ
provedenÌ je s pÏti nava¯en˝mi h·Ëky.
The size of the panel is either 1U or 2U. The
1U panel can hold up to 5 cable supports size
1x1U or 5 cable supports size 1x2U. The
2U panel can hold up to 5 cable supports (size
2x2U only) welded on. The standard panels come
with five welded cable supports.
Informace k objedn·vce / Ordering Information:
panely s nava¯en˝mi h·Ëky / panels with cable supports welded on
strana 20
panel 1U s h·Ëky 1x1U / 1U panel with cable supports 1Ux1U
HV-01-NH
panel 1U s h·Ëky 1x2U / 1U panel with cable supports 1Ux2U
HV-02-NH
panel 2U s h·Ëky 2x2U / 2U panel with cable supports 2Ux2U
HV-03-NH
DOPL“KY / ACCESSORIES
Panely s montovateln˝mi h·Ëky
Panels with Cable Supports Screwed on
Panely jsou dod·v·ny ve dvou velikostech 1U a 2U.
Na panel mohou b˝t namontov·ny h·Ëky v poËtu
1-7 ks o rozmÏrech 1x1U, 1x2U nebo 2x2U, dle
Vaöeho poûadavku.
Pro tuto aplikaci se pouûÌvajÌ identickÈ h·Ëky jako
pro vertik·lnÌ vedenÌ kabel˘.
Povrchov· ˙prava je provedena potaûenÌm plastem
ËernÈ barvy.
The size of the panel is either 1U or 2U. Each
panel can hold up to 7 cable supports size
1Ux1U, 1Ux2U or 2Ux2U screwed on. The number
of cable supports depends on your wish. Cable
supports used for this application are identical
with those used for vertical cable routing.
The cable supportsare covered with black plastic
coating.
Informace k objedn·vce / Ordering Information:
panely s montovateln˝mi h·Ëky / panels with cable supports screwed on
panel 1U k mont. 1-7 h·Ëk˘ / 1U for 1-7 cable supports
HV-04-MH
panel 2U k mont. 1-7 h·Ëk˘ / 2U for 1-7 cable supports
HV-05-MH
Police
Support Shelves
Pro menöÌ za¯ÌzenÌ, kterÈ nenÌ moûnÈ upevnit do
19î, jsou do sk¯ÌnÌ ZERAK dod·v·ny 19" konzolovÈ
police, kterÈ se p¯Ìmo upevÚujÌ na ˙helnÌky
k mont·ûi panel˘. Jsou provedeny v hloubk·ch
250 mm, 350 mm a 450 mm o v˝öce 1U a 2U.
Dno polic je opat¯eno otvory pro snazöÌ ventilaci
p¯i pouûitÌ ventilaËnÌch jednotek.
Povrchov· ˙prava je provedena pr·ökovou barvou
RAL v odstÌnu öed· 7035.
ZERAK cabinets are supplied with 19" equipment
support shelves on brackets. These support
shelves serve for small equipment that cannot be
mounted into 19". They are mounted directly on
panel/slide mounts. The support shelves are supplied in the following variations: depth 250 mm,
350 mm and 450 mm and height 1U and 2U. The
bottom of these equipment support shelves is
perforated to allow easier air circulation when
ventilation units are used.
The surface texture of the support shelves is
painted gray RAL 7035.
Informace k objedn·vce / Ordering Information:
police / shelf 250 mm, 1U
PL-1U-K
police / shelf 350 mm, 1U
PL-1U-D
police / shelf 250 mm, 2U
PL-2U-K
police / shelf 350 mm, 2U
PL-2U-D
police / shelf 450 mm, 2U
PL-2U-X
strana 21
DOPL“KY / ACCESSORIES
Police pro UPS
UPS Support Shelves
Pro snadnÈ umÌstÏnÌ levn˝ch nep¯etrûit˝ch
nap·jecÌch zdroj˘ UPS do sk¯ÌnÌ ZERAK se vyr·bÌ
police UPS o vnÏjöÌ v˝öce p¯Ìruby 2U pro umÌstÏnÌ
UPS 400. Tato police je urËena pro mont·û na
˙helnÌky k mont·ûi panel˘.
M˘ûeme vyrobit zvl·ötnÌ police pro r˘znÈ druhy
UPS podle vaöeho p¯·nÌ.
Povrchov· ˙prava je provedena pr·ökovou barvou
RAL v odstÌnu öed· 7035.
UPS support shelves are manufactured for
an easier placement of UPS (uninterruptible
power system) equipment into ZERAK cabinets.
These shelves for the placement of UPS 400 have
the outside height of 2U. They are intended to
be mounted on panel/slide mounts. We can
manufacture specific shelves for various types of
UPS equipment to suit your particular wishes.
The surface texture of UPS support shelves is
painted gray RAL 7035.
Informace k objedn·vce / Ordering Information:
police pro UPS 2U / UPS support shelf, height 2U
PL-2U
Drû·k police
Slide Rails
Zajiöùuje buÔto p¯Ìmou podporu za¯ÌzenÌ nebo
slouûÌ jako podpÏra police pro vÏtöÌ zatÌûenÌ, aniû
by doölo ke ztr·tÏ v˝öky ve sk¯Ìni. Montuje se
p¯Ìmo na ˙helnÌky k mont·ûi panel˘. Dod·v·me ve
dvou provedenÌch:
a) pro ZERAK 3000, 4000 a 8000
b) pro ZERAK 2000
Povrchov· ˙prava je provedena pr·ökovou barvou
RAL v odstÌnu öed· 7035.
Slide rails serve both for direct equipment
support and for holding shelves that carry
a heavier load. They do not cause any loss of
vertical space inside the cabinet. Slide rails are
mounted directly on the panel/slide mounts.
They are supplied in two variations:
a) for ZERAK 3000, 4000 and 8000
b) for ZERAK 2000
The surface texture of the slide rails is painted
gray RAL 7035.
Informace k objedn·vce / Ordering Information:
strana 22
drû·k police / slide rail ZERAK 3000, 4000, 8000
DK-01
drû·k police / slide rail ZERAK 2000
DK-02
DOPL“KY / ACCESSORIES
Mont·ûnÌ sada
Assembly Parts Pack
Mont·ûnÌ sada M6 slouûÌ k upevnÏnÌ za¯ÌzenÌ do The M6 assembly parts serve for the mounting of
19ì r·mu.
equipment into the 19ì frame.
Sada obsahuje: 4x öroubek
One pack includes:
4 screws
4x plastov· podloûka
4 plastic washers
4x klecov· matka (plovoucÌ)
4 cage nuts
Informace k objedn·vce / Ordering Information:
mont·ûnÌ sada M6 / M6 assembly parts pack
MONT
ZaslepovacÌ panely
Blank Filler Panels
K 19î sk¯ÌnÌm ZERAK jsou dod·v·ny zaslepovacÌ
panely v z·kladnÌch v˝ök·ch 1U, 2U, 3U, 4U a 6U.
Povrchov· ˙prava panel˘ je provedena pr·ökovou
barvou RAL v odstÌnu Ëern· 9005 hedv·bn˝ lesk
polomatn˝.
Na objedn·vku dod·v·me zaslepovacÌ panely
1- 12U vyrobenÈ dle normy »SN IEC 297-1
19" cabinets are supplied with blank filler panels
in the following nominal heights: 1U, 2U, 3U, 4U,
and 6U.
The surface texture of these blank filler panels is
painted black RAL 9005, soft half-matt (ivory).
Blank filter panels manufactured according to
»SN IEC 297-1 can be supplied upon the
customerís request.
Informace k objedn·vce / Ordering Information:
zaslepovacÌ panely dle normy »SN IEC 297-1
zaslepovacÌ panel 1U / blank filler panel 1U
ZA-1U-01
zaslepovacÌ panel 2U / blank filler panel 2U
ZA-2U-01
zaslepovacÌ panel 3U / blank filler panel 3U
ZA-3U-01
zaslepovacÌ panel 4U / blank filler panel 4U
ZA-4U-01
zaslepovacÌ panel 5U / blank filler panel 5U
ZA-5U-01
zaslepovacÌ panel 6U / blank filler panel 6U
ZA-6U-01
zaslepovacÌ panel 7U / blank filler panel 7U
ZA-7U-01
zaslepovacÌ panel 8U / blank filler panel 8U
ZA-8U-01
Informace k objedn·vce / Ordering Information:
zaslepovacÌ panel 1U / blank filler panel 1U
ZA-1U
zaslepovacÌ panel 9U / blank filler panel 9U
ZA-9U-01
zaslepovacÌ panel 2U / blank filler panel 2U
ZA-2U
zaslepovacÌ panel 10U / blank filler panel 10U
ZA-10U-01
zaslepovacÌ panel 3U / blank filler panel 3U
ZA-3U
zaslepovacÌ panel 11U / blank filler panel 11U
ZA-11U-01
zaslepovacÌ panel 4U / blank filler panel 4U
ZA-4U
zaslepovacÌ panel 12U / blank filler panel 12U
ZA-12U-01
zaslepovacÌ panel 6U / blank filler panel 6U
ZA-6U
strana 23
DOPL“KY / ACCESSORIES
Patch-panely
Patch-panels
Jako komponenty pro budov·nÌ datov˝ch
a telekomunikaËnÌch sÌtÌ jsou dod·v·ny
propojovacÌ panely patch-panely.
Jsou vyr·bÏny o r˘znÈm poËtu otvor˘ 16, 24, 32,
48, 64. Maxim·lnÌ v˝öka panelu je 4U.
Povrchov· ˙prava je provedena pr·ökovou barvou
RAL v odstÌnu Ëern· 9005.
Connecting panels - patch-panels - are supplied
as components for the construction of data and
telecommunication networks. They are available
with a variable number of cut-outs: 16, 24, 32,
48, and 64. The maximum height of patch-panels
is 4U.
The surface texture of the patch-panels is
painted black RAL 9005.
Informace k objedn·vce / Ordering Information:
1U -16 otvor˘ / cut-outs
PP-16
2U -24 otvor˘ / cut-outs
PP-24
2U -32 otvor˘ / cut-outs
PP-32
3U -48 otvor˘ / cut-outs
PP-48
4U -64 otvor˘ / cut-outs
PP-64
RozmÏry otvor˘ pro konektory v patch-panelu
Connector hole dimensions in the patch-panel
strana 24
DOPL“KY / ACCESSORIES
HrazdiËka
Cable Support Rail
ZajÌmav˝ doplnÏk slouûÌcÌ k vyv·z·nÌ kabel˘
vedoucÌch k patch-panel˘m. Je vyr·bÏna v z·kladnÌch
v˝ök·ch 1U, 2U, 3U, 4U. Montuje se pod
patch-panely na ˙helnÌky k mont·ûi panel˘.
Skl·d· se ze t¯Ì Ë·stÌ: dvou bok˘ pro uchycenÌ do
19î r·mu a z perforovanÈ p¯ep·ûky. Na tuto
p¯ep·ûku se vyvazujÌ vlastnÌ kabely pomocÌ
prov·zk˘ Ëi PVC vyvazovacÌch p·sek. Od velikosti
2U je moûnÈ p¯Ìpevnit k bok˘m aû 4 perforovanÈ
p¯ep·ûky.
Povrchov· ˙prava je provedena pr·ökovou barvou
RAL v odstÌnu Ëern· 9005.
The cable support rail is an interesting accessory
that serves for cable management - for clamping
cables that lead towards patch-panels. It is
available in these nominal heights: 1U, 2U, 3U,
and 4U. It is mounted below patch-panels onto
panel/slide mounts for panel mounting. The
cable support rail consists of three parts: two
side parts for mounting into the 19" frame and
a perforated rail. This rail is directly used for
clamping cables by means of strings or PVC plastic
cable support strips. For cable support rails of 2U
and more, it is possible to fix up to four perforated
rails to the side parts.
The surface texture of the cable support rail is
painted black RAL 9005.
⁄chyt perforovanÈ p¯ep·ûky
Cable Support Rail Holder
Tento ˙chyt je zjednoduöenou alternativou boËnÌch
dÌl˘, kterÈ drûÌ perforovanou p¯ep·ûku pouûÌvanou
k p¯ÌmÈmu vyv·z·nÌ kabel˘. äroubuje se p¯Ìmo
na ˙helnÌky k mont·ûi panel˘. Moûno pouûÌt jen
u rozvadÏˢ ZERAK.
This holder is a simplified alternative to the side
parts that hold the perforated rail used for direct
cable management. It is screwed directly onto
panel/slide mounts for panel mounting. This
holder can be used only in ZERAK cabinets.
Informace k objedn·vce / Ordering Information:
hrazdiËka 1U / cable support rail 1U
HR-1U-01
hrazdiËka 2U / cable support rail 2U
HR-2U-01
hrazdiËka 3U / cable support rail 3U
HR-3U-01
hrazdiËka 4U / cable support rail 4U
HR-4U-01
perforovan· p¯ep·ûka / perforated rail
HR-0U-01
˙chyt perforovanÈ p¯ep·ûky / cable support rail holder
UC-01-01
strana 25
DOPL“KY / ACCESSORIES
strana 26
Z·vÏsn˝ drû·k (n·stÏnn˝)
Hinged 19î Wall-mounted Bracket
Novou moûnostÌ instalace kabel˘ je pouûitÌ
z·vÏsnÈho drû·ku k mont·ûi patch-panel˘. Tento
drû·k je urËen k p¯ÌmÈ mont·ûi na zeÔ a umoûÚuje
upevnÏnÌ menöÌho mnoûstvÌ kabel˘, bez nutnosti
instalace rozvadÏËe. Nev˝hodou tohoto zp˘sobu
mont·ûe je snadnÈ mechanickÈ poökozenÌ, voln˝
p¯Ìstup vzduchu, neËistot a jejich n·slednÈ usazov·nÌ.
V˝hodou jsou pak nÌzkÈ po¯izovacÌ n·klady. Tyto
n·stÏnnÈ drû·ky jsou dod·v·ny ve t¯ech z·kladnÌch
v˝ök·ch 2U, 3U a 4U.
Povrchov· ˙prava je provedena pr·ökovou barvou
RAL v odstÌnu Ëern· 9005.
This bracket serves for direct mounting of
patch-panels on walls without the necessity to use
network cabinets. The bracket is intented for
a smaller number of cables on the one hand, this
is a low-cost alternative but on the other, it can
suffer easy mechanical damage and it is open
construction allows air to enter and, consequently,
dust to deposit on the installed connections. The
hinged 19î wall-mounted bracket is supplied in
three nominal sizes 2U, 3U and 4U.
The surface texture of the hinged 19î wall-mounted
bracket is painted black RAL 9005.
Informace k objedn·vce / Ordering Information:
z·vÏsn˝ drû·k 2U / hinged 19î wall-mounted bracket 2U
ZD-2U
z·vÏsn˝ drû·k 3U / hinged 19î wall-mounted bracket 3U
ZD-3U
z·vÏsn˝ drû·k 4U / hinged 19î wall-mounted bracket 4U
ZD-4U
DOPL“KY / ACCESSORIES
OsvÏtlovacÌ jednotka
Strip-Light Unit
Pro snazöÌ manipulaci a p¯ehlednost ve sk¯ÌnÌch
ZERAK se dod·v· z·¯ivkovÈ svÌtidlo, montovanÈ do
hornÌho r·mu sk¯ÌnÏ. Jedn· se o svÌtidlo modernÌho
tvaru s vysok˝m v˝konem, nÌzkou spot¯ebou
a dlouhou ûivotnostÌ. Ovl·d·nÌ je vypÌnaËem na
tÏle svÌtidla.
Technick· data:
220V, 50Hz, v˝kon 8W
RozmÏry: 340x20x70 mm
ZERAK cabinets are equipped with a strip-light for
easy manipulation and clear management. This
light unit is mounted in the upper frame of the
cabinet. The light unit has a modern shape, high
efficiency, low consumption and long working
life. The switch is positioned on the body of the
light unit.
Technical data:
220V, 50Hz, 8W
Dimension: 340x20x70 mm
Informace k objedn·vce / Ordering Information:
z·¯ivkovÈ svÌtidlo / strip-light unit
OS-01-DS
Z·suvkov˝ systÈm do 19î
Socket Strip
RozvodnÈ panely p¯ipojujÌ aktivnÌ za¯ÌzenÌ
v rozvadÏËi k rozvodnÈ sÌti 220 V. Jsou dod·v·ny
ve dvou provedenÌch s pÏti nebo t¯emi z·suvkami.
PouûitÌ z·suvky ACAR s odruöovacÌm filtrem
a ochranou proti p¯epÏtÌ je schv·leno st·tnÌ
zkuöebnou EZU.
JmenovitÈ hodnoty max. 6 A, 250 V
Socket strips power extension provide power for
the active equipment inside a cabinet. They are
supplied with three or five sockets. Filtered, 220
V, with a switch and a fuse; maximum 6 A, 250 V.
The ACAR socket strips have been approved by
the EZU state approval office.
Informace k objedn·vce / Ordering Information:
rozvodn˝ panel 220 V/3 pozice / socket strip, switched, 220V/3-way DZ-01-03
rozvodn˝ panel 220 V/5 pozice / socket strip, switched, 220V/5-way DZ-01-05
strana 27
DOPL“KY / ACCESSORIES
VentilaËnÌ jednotka umÌstÏn· v r·mu Frame Fan Unit/Fan Trays
ZERAK 3000, 4000, 8000
ZERAK 3000, 4000, 8000
Na objedn·vku je dod·v·na ventilaËnÌ jednotka,
urËen· zejmÈna k mont·ûi do hornÌho nebo
dolnÌho r·mu sk¯ÌnÏ ZERAK. SlouûÌ k ochlazov·nÌ
instalovan˝ch za¯ÌzenÌ. Tyto ventilaËnÌ jednotky
lze namontovat i dodateËnÏ, bez zmenöenÌ vyuûitelnÈ
v˝öky rozvadÏËe.
ZapÌn·nÌ je provedeno kolÈbkov˝m vypÌnaËem
s diodou oznaËujÌcÌ funkci. VentilaËnÌ jednotka je
jiötÏna p¯epÏùovou pojistkou.
VentilaËnÌ jednotka v r·mu je sloûena z jednoho
aû devÌti ventil·tor˘ dle pot¯eby. NamontovanÈ
ventil·tory jsou nap·jeny st¯Ìdav˝m napÏtÌm
220V, 50Hz a zaruËujÌ pr˘tok 109 m3/hod. na jeden
ventil·tor.
If ordered, a ventilation unit is supplied for ZERAK
cabinets. It is intended to be mounted mainly to
the upper or lower frame. It serves for cooling
down the installed equipment. These fan units
can also be mounted additionally without
decreasing the disposable height of the
network cabinet.
The fan unit is turned on with a switch. There is
a light indicating that the fan unit is on. It contains
a fuse.
The frame fan unit consists of 1 - 9 fans, according
to your specific need. The mounted fans need
220V voltage, 50Hz. Each fan will provide 109 m3
of air per hour.
VentilaËnÌ jednotka je dod·v·na ve t¯ech z·kladnÌch The fan unit is supplied in three basic variations:
provedenÌch:
a) with three fans (in the centre row)
a) se t¯emi ventil·tory (zaplnÏnÈ pole uprost¯ed)
b) with five fans (in the corners and the centre)
b) s pÏti ventil·tory (osazenÈ v rozÌch a uprost¯ed)
c) with nine fans (in all nine fan positions)
c) s devÌti ventil·tory (plnÏ osazenÈ pole)
The highest efficiency of ventilation can be
NejvyööÌho ventilaËnÌho efektu je dosaûeno achieved by using fan units mounted in both the
pouûitÌm ventilaËnÌ jednotky namontovanÈ do upper and the lower frames.
hornÌho i dolnÌho r·mu.
The surface texture of the frame fan unit is
Povrchov· ˙prava je provedena pr·ökovou barvou painted gray RAL 7035.
RAL v odstÌnu öed· 7035.
Informace k objedn·vce / Ordering Information:
ventilaËnÌ jednotka / frame fan unit
se t¯emi ventil·tory / with three fans
VJ-R5
s devÌti ventil·tory / with nine fans
VJ-R9
RozmÌstÏnÌ ventil·tor˘ ve ventilaËnÌch jednotk·ch
Ventilator positions in the fan unit
strana 28
VJ-R3
s pÏti ventil·tory / with five fans
DOPL“KY / ACCESSORIES
VentilaËnÌ jednotka umÌstÏn·
do vÌka ZERAK 2000
VentilaËnÌ jednotka se dod·v· ve dvou z·kladnÌch
provedenÌch se dvÏma nebo Ëty¯mi ventil·tory.
NamontovanÈ ventil·tory jsou nap·jeny st¯Ìdav˝m
napÏtÌm 220V/50 Hz a zaruËujÌ pr˘tok 109 m3/hod.
na jeden ventil·tor. ZapÌn·nÌ je provedeno
kolÈbkov˝m vypÌnaËem s diodou oznaËujÌcÌ funkci.
VentilaËnÌ jednotka je jiötÏna p¯epÏùovou pojistkou.
Fan Unit for ZERAK 2000
The fan unit is supplied in two basic variations
with two or four fans. The mounted fans need
220 voltage, 50 Hz, A.C.. Each fan provides 109 m3
of air per hour.
The fan unit is turned on with a switch. There is
a light indicating that the fan unit is on. It
contains a fuse.
The surface texture is painted gray RAL 7035.
Povrchov· ˙prava je provedena pr·ökovou barvou
RAL v odstÌnu öed· 7035.
Informace k objedn·vce / Ordering Information:
se dvÏma ventil·tory / with two fans
VJ-M2
se Ëty¯mi ventil·tory / with four fans
VJ-M4
RozmÌstÏnÌ ventil·tor˘ ve ventilaËnÌch jednotk·ch
Ventilator positions in the fan unit
VentilaËnÌ jednotka do 19î
19" Frame Fan Unit
D·le se dod·v· ventilaËnÌ jednotka urËen·
k umÌstÏnÌ do 19î r·mu. Lze ji umÌstit libovolnÏ
po celÈ svÏtlÈ v˝öce sk¯ÌnÏ. Obsahuje 3 ventil·tory.
NamontovanÈ ventil·tory jsou nap·jeny st¯Ìdav˝m
napÏtÌm 220V, 50Hz a zaruËujÌ pr˘tok 327 m3/hod.
ZapÌn·nÌ je provedeno kolÈbkov˝m vypÌnaËem
s diodou oznaËujÌcÌ funkci. VentilaËnÌ jednotka je
jiötÏna p¯epÏùovou pojistkou.
Povrchov· ˙prava je provedena pr·ökovou barvou
RAL v odstÌnu öed· 7035.
A fan unit for the 19" frame is also supplied. The
fan tray can be placed anywhere in the disposable
height of the cabinet. It contains three fans. The
mounted fans need 220V voltage, 50Hz, A.C..
They provide 327 m3 of air per hour.
The fan unit is turned on with a switch. There is
a light indicating that the fan unit is on. It contains
a fuse.
The surface texture of the 19" frame fan unit is
painted gray RAL 7035.
Informace k objedn·vce / Ordering Information:
ventilaËnÌ jednotka do 19î/ 19î frame fan unit
VJ-19-03
strana 29
DOPL“KY / ACCESSORIES
ZemnÌcÌ k·blÌky
Earthing Cables
ZemnÌcÌ k·blÌky slouûÌ k vodivÈmu spojenÌ
jednotliv˝ch Ë·stÌ rozvadÏËe a n·slednÈ uzemnÏnÌ
v jednom bodÏ. Jsou dod·v·ny sady zemnÌcÌch
k·blÌk˘ pro rozvadÏËe ¯ady ZERAK 2000, 3000,
4000 a 8000.
Earthing cables serve for the mutual connective
connection of individual parts of the cabinet and
their subsequent grounding in one place. Packs
of earthing cables are supplied for ZERAK 2000,
3000, 4000 and 8000 cabinets.
Informace k objedn·vce / Ordering Information:
zemnÌcÌ k·blÌky pro / earthing cables for
ZERAK 2000
zemnÌcÌ k·blÌky pro / earthing cables for
ZM-02
ZERAK 3000, 4000, 8000 ZM-03
Earthing Bridge
for ZERAK 3000, 4000, 8000
ZemnÌcÌ m˘stek
pro ZERAK 3000, 4000, 8000
Na objedn·vku jsou sk¯ÌnÏ vybavov·ny mÏdÏn˝m If ordered, ZERAK cabinets can be supplied with
zemnÌcÌm m˘stkem k uzemnÏnÌ elektrick˝ch a copper earthing bridge that serves for earthing
electrical equipment mounted inside the cabinet.
za¯ÌzenÌ, namontovan˝ch ve sk¯Ìni.
Informace k objedn·vce / Ordering Information:
zemnÌcÌ m˘stek pro / earthing bridge for
strana 30
ZERAK 3000, 4000, 8000
ZM-01
DOPL“KY / ACCESSORIES
Drû·k monitoru
uchycenÌ monitoru do 19î
Monitor Box
for mounting monitors into 19î
Drû·k monitoru slouûÌ pro rychlÈ a bezproblÈmovÈ
umÌstÏnÌ prakticky libovolnÈho 14î-17î monitoru
do 19î sk¯ÌnÏ. PomocÌ nastaviteln˝ch z·vÏs˘ se
monitor umÌstÌ do drû·ku. ZneËiötÏnÌ obrazovky
monitoru zabraÚujÌ molitanovÈ vymezovacÌ hranolky.
K ochranÏ obrazovky je pouûito plexisklo,
na objedn·vku je moûno pouûÌt i sklo. P¯Ìstup
k ovl·dacÌm prvk˘m monitoru je moûn˝
odnÌmateln˝m p¯ednÌm krytem. Vyr·bÌ se dvÏ
varianty pro 14-15î monitor a 17î monitor.
Osazen· v˝öka je 9U.
Drû·k monitoru se skl·d· z:
1x ËelnÌ panel
2x boËnÌ panel
2x kr·tk˝ z·vÏs
1x dlouh˝ z·vÏs
Povrchov· ˙prava je provedena pr·ökovou barvou
RAL v odstÌnu öed· 7035.
The monitor holder serves for a quick and easy
placement of almost any 14î-17î monitor into
a 19î cabinet. A monitor is fixed in the monitor box
with adjustable supports. Plastic foam deliminative
prisms protect the monitor screen from dirt.
Further screen protection is provided with plexiglass,
which can be replaced with glass upon
a customerís order. The replaceable front panel
enables access to the controls of the monitor. Two
variants are supplied - for a 14î-15î monitor and
a 17î monitor. The monitor box occupies 9U inside
a cabinet.
The monitor box consists of:
1 front panel
2 side panels
2 short supports
1 long support
The surface texture is painted gray RAL 7035.
Informace k objedn·vce / Ordering Information:
drû·k 14î monitoru / 14î monitor box
MN-19-14
drû·k 17î monitoru / 17î monitor box
MN-19-17
z·vÏs kr·tk˝ / support - short
MN-ZV-01
z·vÏs dlouh˝ / support - long
MN-ZV-02
vÌko / top cover
MN-VO-01
strana 31
OPTICK… ROZVADûE / FIBER OPTIC NETWORK CABINETS
Pro instalaci a ochranu vedenÌ optick˝ch kabel˘
p¯i jejich spojov·nÌ jsou urËeny optickÈ sk¯ÌÚky
k mont·ûi na stÏnu.
Jsou vyr·bÏny ve dvou provedenÌch:
a) optick· sk¯ÌÚka mal·
b) optick· sk¯ÌÚka velk·
For installation and protection of fiber optic cable
routing during their connecting, wall-mounted
fiber optic cabinets have been designed.
They are manufactured and made available in two
variations:
a) big-size fiber optic cabinet
b) small-size fiber optic cabinet
Optick· sk¯ÌÚka mal·
Small-Size Fiber Optic Cabinet
Vyuûiteln˝ prostor o rozmÏrech 297x175x51 mm,
kter˝ je uzav¯en p¯iöroubovan˝m krytem. Sk¯ÌÚka
je opat¯ena dvÏma vstupy/v˝stupy, kryt˝mi
konektorov˝mi panely.
Povrchov· ˙prava je provedena pr·ökovou barvou
RAL v odstÌnu öed· 7035 .
Disposable space dimensions are 297x175x51 mm.
The cover is secured with screws. The cabinet
contains two cable entry/exit points that are
covered with connector panels.
The surface texture of the small-size fiber optic
cabinet is painted gray RAL 7035.
VenkovnÌ rozmÏry / External dimensions:
ö̯ka / width
v˝öka / height
300
178
(mm)
hloubka / depth
54
Informace k objedn·vce / Ordering Information:
optick· sk¯ÌÚka mal· / small-size fiber optic cabinet
Optick· sk¯ÌÚka velk·
Big-Size Fiber Optic Cabinet
Vyuûiteln˝ prostor o rozmÏrech 292x297x102 mm.
Sk¯ÌÚka je uzamykateln· vËetnÏ krytu konektor˘
na propojovacÌm panelu. Na propojovacÌ panel
mohou b˝t namontov·ny aû Ëty¯i konektorovÈ
panely dle poûadavku.
Povrchov· ˙prava je provedena pr·ökovou barvou
RAL v odstÌnu öed· 7035.
Disposable space dimensions are 292x297x102 mm.
The cabinet is lockable, including the connector
cover on the connecting panel. The connecting
panel can carry up to four connector panels, the
number depending on the customerís wish.
The surface texture of the big-size fiber optic
cabinet is painted gray RAL 7035.
VenkovnÌ rozmÏry / External dimensions:
ö̯ka / width
v˝öka / height
400
strana 32
FO-01-SM
300
(mm)
hloubka / depth
104
Informace k objedn·vce / Ordering Information:
optick· sk¯ÌÚka velk· / big-size fiber optic cabinet
FO-01-SK
OPTICK… ROZVADûE / FIBER OPTIC NETWORK CABINETS
KonektorovÈ panely
Connector Panels
Jsou urËeny k mont·ûi do optick˝ch sk¯ÌnÏk a 19"
polic pro optiku. Pojmou aû 8 adaptÈr˘ typu SMA,
ST, BNC a DIN 47256 nebo 2 adaptÈry FDDI nebo
6 adaptÈr˘ typu SC nebo 4 adaptÈry typu SC
Duplex.
Povrchov· ˙prava je provedena pr·ökovou barvou
RAL v odstÌnu öed· 7035 nebo Ëern· 9005.
Connector panels are intended for mounting into
fiber optic cabinets and 19" shelves for fiber optic
connectors. They can hold up to either eight
SMA, ST, BNC or DIN 47256 adaptors or two
FDDI adaptors or six SC adaptors or four SC
Duplex adaptors.
The surface texture of the connector panels is
painted gray RAL 7035 or black RAL 9005.
Informace k objedn·vce/Ordering Information:
konektorov˝ panel / connector panel
pln˝ zaslepovacÌ / plain (unperforated)
KO-00
pro ST konektory / for ST connectors
KO-ST
pro FDDI konektory / for FDDI connectors
KO-FDDI
pro SMA konektory / for SMA connectors
KO-SMA
pro BNC konektory / for BNC connectors
KO-BNC
pro DIN 47256 konektory / for DIN 47256 connectors
KO-DIN
pro SC konektory / for SC connectors
KO-SC
pro SC Duplex konektory / for SC Duplex connectors
KO-SCD
strana 33
OPTICK… ROZVADûE / FIBER OPTIC NETWORK CABINETS
19" police pro optiku
19" Shelves for Fiber Optic Connectors
Jsou urËeny k instalaci a k zakonËov·nÌ optick˝ch
vedenÌ v 19" sk¯Ìni.
Jsou dod·v·ny ve dvou velikostech 1 a 2U. Police
jsou Ë·steËnÏ zapuötÏnÈ ve sk¯Ìni, aby p¯i osazenÌ
optick˝mi propojkami nedoch·zelo k jejich
mechanickÈmu poökozenÌ.
19î police se skl·d· ze dna, odnÌmatelnÈho vÌka,
zamÏnitelnÈho ËelnÌho a zadnÌho panelu.
»elnÌ panel m˘ûe b˝t:
a) s otvory pro konektory 16 ST, 24 ST, 16 SC,
16 SC Duplex a 6 FDDI u polic velikosti 1U nebo
48 ST, 32 SC, 32 SC Duplex a 12 FDDI u polic
velikosti 2U
b) s konektorov˝mi panely, u velikosti police 1U
dvÏma, u velikosti police 2U Ëty¯mi.
These shelves are intended for installation and
termination of fiber optic routing in the 19"
cabinet. They are supplied in two dimensions - 1U
and 2U. The shelves are slightly pushed to the
background inside the cabinet to avoid mechanical
damage incurred while plugging in mechanical
connectors.
The 19" shelf consists of the bottom plate,
replaceable top cover plate and the variable front
and rear panels.
The front panel may have the following
variations:
a) 1U shelf can have 16 or 24 cut-outs for ST
connectors, 16 cut-outs for SC connectors,
16 cut-outs for SC Duplex; 2U shelf can have
48 cut-outs for ST connectors, 32 cut-outs for
SC connectors, 32 cut-outs for SC Duplex
connectors and 12 cut-outs for FDDI connectors
b) 1U shelf can have two connector panels; 2U shelf
can have four connector for panels.
KonektorovÈ panely, urËenÈ k mont·ûi do
optick˝ch sk¯ÌnÏk a 19" polic pro optiku, pojmou
aû 8 adaptÈr˘ typu SMA, ST, BNC a DIN 47256,
6 adaptÈr˘ SC, 4 adaptÈry SC Duplex nebo
2 adaptÈry FDDI.
OsazenÌm tÏchto konektorov˝ch panel˘ m˘ûeme
v jednÈ 19î polici pro optiku umÌstit nÏkolik druh˘
konektor˘, aniû by doölo ke ztr·tÏ v˝öky ve sk¯Ìni.
Povrchov· ˙prava je provedena pr·ökovou barvou
RAL v odstÌnu öed· 7035.
Connector panels that are intended to be mounted
into fiber optic cabinets and 19" shelves for fiber
optic connectors can hold up to eight SMA, ST,
BNC or DIN 47256 adaptors or two FDDI adaptors.
By mounting these connector panels, several
types of connectors can be mounted in one 19"
shelf for fiber optic connectors without sacrificing
any disposable height in the cabinet.
The surface texture of the 19" shelves is painted
gray RAL 7035.
Informace k objedn·vce/Ordering Information:
19î police pro optiku / 19" shelf for fiber optic connectors
strana 34
1U zaslepen· / height 1U, plain (unperforated)
FO-19-00
1U s otvory pro konektorovÈ panely / height 1U, with cut-outs for connector panels
FO-19-01
1U s 16 ST otvory / height 1U, with 16 cut-outs (ST-type)
FO-19-02
1U s 24 ST otvory / height 1U, with 24 cut-outs (ST-type)
FO-19-03
1U s 16 SC otvory / height 1U, with 16 cut-outs (SC-type)
FO-19-07
1U s 16 SC Duplex otvory / height 1U, with 16 cut-outs (SC-Duplex type)
FO-19-08
1U s 6 FDDI otvory / height 1U, with 6 cut-outs (FDDI-type)
FO-19-09
OPTICK… ROZVADûE / FIBER OPTIC NETWORK CABINETS
Schema sestavenÌ optickÈ police / Optical mounting design
Informace k objedn·vce/Ordering Information:
19î police pro optiku / 19" shelf for fiber optic connectors
2U zaslepen· / height 2U, plain (unperforated)
FO-19-04
2U s otvory pro konektorovÈ panely / height 2U, with cut-outs for connector panels
FO-19-05
2U s 48 ST otvory / height 2U, with 48 cut-outs (ST-type)
FO-19-06
2U s 32 SC otvory / height 2U, with 32 cut-outs (SC-type)
FO-19-10
2U s 32 SC Duplex otvory / height 2U, with 32 cut-outs (SC Duplex-type)
FO-19-11
2U s 12 FDDI otvory / height 2U, with 12 cut-outs (FDDI-type)
FO-19-12
strana 35
VäEOBECN… OBCHODNÕ PODMÕNKY / GENERAL TERMS OF SALE
Vztah mezi firmou MegaNET spol. s r.o. (d·le jen prod·vajÌcÌ) a jejÌmi z·kaznÌky
(d·le jen kupujÌcÌ) upravujÌ vöeobecnÈ obchodnÌ podmÌnky. KupujÌcÌ p¯ijÌm·
platnost obchodnÌch podmÌnek odbÏrem zboûÌ u prod·vajÌcÌho a tÌmto aktem
pro nÏj vstupujÌ v platnost.
The following general terms of sale regulate the relation between the
MegaNET Ltd. company (the seller) and its customers (the buyers). The
buyer agrees to accept the terms of sale which come into effect at the
moment of taking over the goods from the seller.
Objedn·v·nÌ zboûÌ
Ordering Goods
P¯i prvnÌ objedn·vce zboûÌ je nutnÈ doloûit v˝pis z ObchodnÌho rejst¯Ìku
(ne staröÌ 3 mÏsÌc˘) nebo éivnostensk˝ list, d·le pak OsvÏdËenÌ o registraci
DPH apod.
Objedn·vky p¯ijÌm·me v pÌsemnÈ formÏ (faxem, poötou, e-mail
[email protected]) nebo p¯i osobnÌm odbÏru vystavenÈ p¯Ìmo pracovnÌky
firmy. Pro bezproblÈmovÈ vy¯izov·nÌ objedn·vek prosÌme o uv·dÏnÌ
n·sledujÌcÌch ˙daj˘ na vöech objedn·vk·ch:
- n·zev a p¯esnou adresu firmy
- ËitelnÈ jmÈno odpovÏdnÈho pracovnÌka
- telefonnÌ, p¯ÌpadnÏ faxovÈ spojenÌ
- Vaöe I»O a DI»
- objednacÌ kÛd zboûÌ (nap¯. 19-12-SS)
- oznaËenÌ a n·zev zboûÌ dle platnÈho cenÌku a katalogu
- poûadovanÈ mnoûstvÌ
- p¯epravnÌ dispozice
- termÌn dod·nÌ
When placing the first order, the following documents have to be presented:
an extract from the Trade Register (within 3 months of the day of issue)
or a Trade Licence, a certificate of VAT registration or other necessary
documents.
Orders can be placed in writing (by fax, by ordinary mail or e-mail:
[email protected]) or in person while taking over the goods. In order to
deal with your orders in an efficient way, we need the following information
to be provided in all your orders:
- your company name and its exact address
- a legible name of the person responsible for the order
- your telephone or fax number
- your company identification number and your tax identification number
- item order codes (e.g. 19-12-SS)
- identification and name of the items according to the latest price list
and catalogue
- requested quantity
- requested means of transportation
- time of delivery
DodacÌ podmÌnky
KupujÌcÌ p¯ebÌr· zboûÌ na z·kladÏ podpisu (s Ëiteln˝m jmÈnem
a p¯ÌjmenÌm) na dodacÌm listu. Podpisem kupujÌcÌ stvrzuje p¯evzetÌ dod·vky
dle mnoûstvÌ a sortimentu a z·roveÚ potvrzuje, ûe dodanÈ zboûÌ nenese zn·mky
zjevn˝ch vad a poökozenÌ. V p¯ÌpadÏ zasl·nÌ na adresu je nutnÈ zboûÌ p¯ed
p¯evzetÌm od p¯epravnÌ spoleËnosti zkontrolovat a pop¯. ihned reklamovat.
VeökerÈ n·klady spojenÈ s p¯epravou hradÌ p¯Ìjemce.
Veöker· ujedn·nÌ o dodacÌch lh˘t·ch musÌ b˝t provedena pÌsemnÏ. VeökerÈ
dodacÌ lh˘ty jsou podmÌnÏny vËasn˝m obdrûenÌm zboûÌ od dodavatel˘.
PlatebnÌ podmÌnky
KupujÌcÌ mohou vyuûÌt t¯ech druh˘ platebnÌch podmÌnek:
a) platba v hotovosti p¯i p¯evzetÌ zboûÌ (v p¯ÌpadÏ zasl·nÌ dobÌrka)
b) platba p¯ed dod·nÌm zboûÌ formou bankovnÌho p¯evodu prost¯ednictvÌm
v˝zvy k platbÏ (proforma faktura)
c) standardnÌ platba se splatnostÌ (faktura)
V p¯ÌpadÏ prvnÌ objedn·vky je vyûadov·na platba uveden· v bodÏ a) nebo b).
U varianty b) od okamûiku vystavenÌ v˝zvy k platbÏ je V·m zboûÌ blokov·no
na skladÏ po dobu 30 dn˘. Pokud v tÈto dobÏ obdrûÌme Vaöi platbu, zboûÌ je
ihned expedov·no. Za doklad o provedenÈ platbÏ je povaûov·n origin·l (p¯i
osobnÌm odbÏru), nebo Ëiteln· kopie jednoho z n·sledujÌcÌch dokument˘:
1) v˝pis z ˙Ëtu s Ëiteln˝m razÌtkem penÏûnÌho ˙stavu a odpovÌdajÌcÌ Ë·stkou
2) bankou potvrzen˝ p¯Ìkaz k ˙hradÏ s odpovÌdajÌcÌ Ë·stkou, variabilnÌm
symbolem a ËÌslem ˙Ëtu podle vystavenÈ v˝zvy k bankovnÌ platbÏ. UvedenÈ
dokumenty je moûno zasÌlat i faxem.
P¯i dlouhodobÏjöÌ spolupr·ci a za podmÌnky dodrûov·nÌ platebnÌ k·znÏ je
moûnÈ sjednat v˝hodnÏjöÌ platebnÌ podmÌnky s delöÌ dobou splatnosti.
V tomto p¯ÌpadÏ je splatnost kupnÌ ceny uvedena na daÚovÈm dokladu
prod·vajÌcÌho. SplatnostÌ se rozumÌ datum, kdy Ë·stka byla p¯ips·na na ˙Ëet
prod·vajÌcÌho.
DealerskÈ kategorie a ceny
Pro prodej jsou stanoveny dvÏ dealerskÈ kategorie D1 a D2. PodmÌnky pro
za¯azenÌ do jednotliv˝ch kategoriÌ jsou n·sledujÌcÌ:
D1
mont·ûnÌ firmy p¯i odbÏru 1-9 ks rozvadÏˢ mÏsÌËnÏ
D2
mont·ûnÌ firmy p¯i odbÏru 10-50 ks rozvadÏˢ mÏsÌËnÏ
DalöÌ slevy lze dohodnout individu·lnÏ dle konkrÈtnÌ dod·vky. Vöechny ceny
jsou uv·dÏny bez DPH a dopravy a jsou platnÈ do vyd·nÌ novÈho cenÌku nebo
jeho doplÚku. Prod·vajÌcÌ si vyhrazuje pr·vo zmÏny cen, kterÈ jsou vyvol·ny
nep¯edvÌdateln˝mi okolnostmi jako jsou zmÏny v celnÌch sazb·ch, kurzech
mÏn atd.
strana 36
Delivery Terms
The buyer takes the goods over after signing the bill of delivery (in full name,
legibly). By signing this bill of delivery, the buyer certifies taking over the
goods in the listed quantity and assortment and the fact that the goods does
not have any visible defects or damage. If the goods is being delivered then
the buyer has to check the goods before taking it over from the transportation
company. Should the buyer find any faulty or damaged items, he has to make
an immediate claim. All costs incurred in relation to the transportation are
covered by the recipient.
All agreements about delivery dates have to be made in writing. All delivery
times depend on a timely delivery of the goods from the suppliers to the seller.
Payment Terms
The buyer can make use of the three following possible ways of payment:
a) payment in cash when taking the goods over (if the goods is sent by mail,
the payment will be cash on delivery)
b) prepayment (prior to the delivery) in the form of a bank transfer based on
a pro-forma invoice
c) standard payment with a maturity date (an invoice)
The payment for the first order can only be in cash or in the form of
prepayment (see a) and b)). In the case of prepayment, the goods will be
reserved for you in our warehouse for 30 days from the day of issue of the
pro-forma invoice. Once your payment of the pro-forma invoice is received,
the goods will be immediately dispatched to you. Either of the following
documents (when taking the goods over in person) or its legible copy is
taken as a proof of payment:
1) bank statement for the given amount, with a legible bank stamp
2) bank payment order for the given amount, certified by the bank, with the
code number and the account number according to the pro-forma invoice.
These documents can be sent by fax.
In the case of a long-term cooperation and a good payment history, more
convenient payment conditions and a later maturity date can be agreed upon.
The maturity date is then listed on the sellerís tax document. Maturity date is
understood as the date when the payment was received at the sellerís
account.
Dealer Categories and Prices
There are two categories of dealers - D1 and D2. The conditions regulating the
dealer categories are as follows:
D1
companies that buy 1 - 9 cabinets each month
D2
companies that buy 10 - 50 cabinets each month
Other discounts can be negotiated individually depending on particular
deliveries. The prices listed in the price list do not include VAT and
transportation costs. All prices are valid until either a supplement or a new
price list is issued. The seller reserves the right to change the prices in
relation to unforeseeablecircumstances such as customs duty changes, rate
of exchange fluctuations, etc.
REKLAMA»NÕ PODMÕNKY / COMPLAINT PROCEDURE
Reklamovat lze pouze zboûÌ, kterÈ bylo zakoupeno u firmy
MegaNET spol. s r.o.. Z·kladnÌ z·ruËnÌ doba je jeden rok, nenÌ-li uvedeno jinak.
Tato doba zaËÌn· bÏûet dnem p¯ed·nÌ zboûÌ kupujÌcÌmu nebo dohodnutÈmu
dopravci (ß425 obchodnÌho z·konÌku) a prodluûuje se o dobu z·ruËnÌ opravy
v˝robku. V p¯ÌpadÏ v˝mÏny zboûÌ se z·ruËnÌ lh˘ta neprodluûuje.
P¯i uplatnÏnÌ reklamace je kupujÌcÌ povinen doruËit zboûÌ na vlastnÌ
n·klady a v p˘vodnÌm obalu. Spolu s reklamovan˝m zboûÌm je nutno p¯edat
kopii dodacÌho listu nebo faktury a pÌsemn˝ popis z·vady (û·dost o reklamaci).
Nebudou-li splnÏny v˝öe uvedenÈ z·leûitosti, reklamace nebude uzn·na
a zboûÌ bude vr·ceno zpÏt kupujÌcÌmu na jeho n·klady. O opr·vnÏnosti
reklamace a zp˘sobu odstranÏnÌ z·vady rozhoduje prodejce. Reklamaci
m˘ûe v˘Ëi dodavateli uplatnit pouze prvnÌ kupujÌcÌ, nem˘ûe ji postoupit dalöÌ
osobÏ.
MÌstem uplatnÏnÌ reklamace je obchodnÌ oddÏlenÌ firmy MegaNET spol. s r.o.
na adrese:
MegaNET spol. s r.o.
Tu¯anka 107
Brno
627 00
»esk· republika
tel.: +420-5-45218878
fax: +420-5-45218876
Reklamaci mechanicky poökozenÈho v˝robku je nutnÈ uplatnit ihned p¯i
osobnÌm odbÏru, nebo v den obdrûenÌ zboûÌ p¯epravnÌ sluûbou. StejnÏ tak je
nutno ihned reklamovat ne˙plnost zboûÌ. Na pozdÏjöÌ reklamace tohoto typu
nebude br·n z¯etel.
Z·ruka se nevztahuje na z·vady:
- zp˘sobenÈ neopr·vnÏn˝m z·sahem do za¯ÌzenÌ
- v d˘sledku pouûitÌ zboûÌ jin˝m neû obvykl˝m ˙Ëel˘m urËen˝m v˝robcem
- nevhodn˝m skladov·nÌm
- poökozenÌ zboûÌ p¯i p¯epravÏ (za zboûÌ odpovÌd· p¯epravce)
- neodbornou instalacÌ nebo mechanick˝m poökozenÌm
A complaint can be placed only on the goods that has been purchased from
MegaNET Ltd. The basic guarantee period is one year if not stated otherwise.
The guarantee period begins on the day when the goods is taken over either
by the buyer or the contracted transportation agent (Commercial Code,
ß425) and is extended for the period during which the product is under
repair. The guarantee period is not extended when the goods is exchanged.
When making a claim, the buyer is obliged to deliver the goods in its
original packing and at his own expense. The product has to be
accompanied with a copy of the appropriate bill of delivery or invoice and
a written description of the defect (a complaint). If these conditions are not
met, the complaint cannot be dealt with and the goods will
be returned to the buyer at his own expense. The power to decide whether
the claim is justified or not rests with the seller, who also decides about
the way in which it will be dealt with. A complaint can be made only by the
first buyer, who cannot cede it to anybody else.
All complaints are to be made at the marketing division of the MegaNET Ltd.
company at the following address:
MegaNET spol. s r.o.
Tu¯anka 107
Brno
627 00
Czech Republic
tel.: +420-5-4521 8878
fax: +420-5-4521 8876
A complaint concerning a mechanically damaged product has to be made
immediately when taking the goods over in person, or, if the goods is
delivered by a transportation company, on the day of the delivery. The same
holds true for incomplete deliveries. The seller will not consider any complaints
for damaged products or incomplete deliveries made later.
The guarantee does not cover:
- any damage caused by unauthorised interference with the equipment
- any damage that may result from such uses that are different from
those intended by the manufacturer
- any damage caused by inappropriate storage
- any damage caused during the transportation (the transportation
company is responsible for the goods)
- any damage caused by inappropriate mounting or mechanical damage
strana 37
N¡VOD MONT¡ûE / ASSEMBLY MANUAL
SestavenÌ r·mu a podesty, mont·û dve¯nÌho z·vÏsu
Frame and Stationary Base Assembly,
Hinge Mounting
Assembly
pack No. 1
Assembly
pack No. 2
P¯ipevnÏnÌ vÌka, p¯ÌËek k mont. ˙helnÌk˘ dna
a podesty k r·mu
Mounting of Top Cover, Depth Members for Panel/slide
Mounts and Stationary Base on the Frame
UchycenÌ boËnÌ stÏny k r·mu a ˙helnÌk˘
k mont·ûi panel˘
Mounting of Side Panel and Panel/ Slide Mounts
Assembly
pack No. 3
Assembly
pack No. 4
strana 38
N¡VOD MONT¡ûE / ASSEMBLY MANUAL
UchcenÌ dve¯Ì k r·mu, sestavenÌ a mont·û kliky
Mont·û zadnÌ stÏny, sestavenÌ z·mk˘ a p¯ipevnÏnÌ
Mounting of Door on the Frame,
Handle Assembly and Mounting
Mounting of Rear Panel on the Frame
Latch Assembly and Mounting
Assembly
pack No. 5
Assembly
pack No. 7
Assembly
pack No. 6
Seznam dÌl˘ v jednotliv˝ch kartonech
Individual boxes contain the following assembly parts
1/3
stojny 4ks -
2x stojna zadnÌ, 1x stojna s otvory pro panty,
1x stojna s otvorem pro z·padku kliky
˙helnÌk k mont·ûi panel˘ 2ks, p¯ÌËky k mont·ûi ˙helnÌk˘ 4ks
4 frame skeleton mounts - 2 rear frame mounts, 1 frame mount with holes for hinges
1 frame mount with an opening for the door handle latch
2 panel/slide mounts, 4 depth members for panel/slide mounts
2/3
p¯ednÌ dve¯e 1ks, boËnÌ stÏna 2ks, zadnÌ stÏna 1ks
1 front door, 2 side panel,1 rear panel
3/3
hornÌ dÌl r·mu 1ks, spodnÌ dÌl r·mu 1ks, vÌko 1ks, dno 2/3 1ks, boËnÌ dÌl podesty s rohy 2ks,
spojovacÌ dÌl podesty pln˝ 1ks, spojovacÌ dÌl podesty s otvorem 1ks, Mont·ûnÌ sada Ë. 1-7
1 upper frame section, 1 lower frame section, 1 top cover
1 stationary bases two - third size base plate
1 side segment with corners
1 stationary base connecting segment with a uniform panel (unperforated)
1 stationary base connecting segment with a hole
Assembly Pack No.1-7
strana 39
PROJEKT MONT¡ûE / MOUNTING DESIGN
Jak˝m zp˘sobem nejlÈpe navrhnout velikost a osazenÌ
sk¯ÌnÏ?
How can you most efficiently decide about the size and
the component layout of your network cabinet?
Zde V·m pro p¯Ìklad uv·dÌme dvÏ snadnÈ moûnosti ¯eöenÌ:
As an example, we outline two easy possible solutions:
a) veöker· za¯ÌzenÌ, kter· chcete do sk¯ÌnÏ umÌstit tj. patch-panely, aktivnÌ
za¯ÌzenÌ, UPS, ventilaËnÌ jednotky, zaslepovacÌ a vyvazovacÌ panely, 19î
police pro optiku atp. si poznaËÌte na protilehlÈ stranÏ. ZjistÌte jejich
velikost v jednotk·ch ìUî, ìUNITî (1U = 44,46 mm) a tyto velikosti k nim
p¯i¯adÌte. Velikosti v ìUî seËtete, p¯id·te dle vlastnÌho uv·ûenÌ rezervu
(velikost rezervy je individu·lnÌ, musÌte vöak poËÌtat do budoucna
s rozö̯enÌm Ëi jin˝mi ˙pravami, kdy kaûd· voln· ìUì pozice bude vÌt·na).
K takto zÌskanÈmu souËtu p¯i¯adÌte nejbliûöÌ vÏtöÌ velikosti sk¯ÌnÏ. TÌm jste
zÌskali optim·lnÌ v˝öku.
a) Note down all the equipment that you want to place in the network
cabinet, i.e. patch-panels, active equipment, UPS, fan units, blank filler
and clamping panels, 19" shelves for fiber optic connectors, etc. on the
opposite page. Find out the dimensions of these appliances in units "U"
(1U=44,46 mm) and write them down. Then count the "U" dimensions
and add a sufficient margin (this is very individual but you should not
fail to take into consideration a future network enlargement or other
space modifications when each free "U" position is welcome). Once you
have this final sum, find the nearest larger dimension of ZERAK network
cabinets. In this way you will determine the optimal height.
b) do nakreslenÈho schematu sk¯ÌnÏ (rozdÏlenÈho po jednotliv˝ch ìUî)
zakreslete jednotliv· za¯ÌzenÌ tj. patch-panely, aktivnÌ za¯ÌzenÌ, UPS,
ventilaËnÌ jednotky, zaslepovacÌ a vyvazovacÌ panely, 19î police pro optiku
atp., v jednotk·ch îUî na jejich p¯esnÈ mÌsto ve sk¯Ìni. ZaËnÏte vûdy ode
dna smÏrem nahoru. TÌmto zakreslenÌm zÌsk·te pat¯iËnou v˝öku. K tÈto
v˝öce p¯idejte dle vlastnÌho uv·ûenÌ rezervu (velikost rezervy je
individu·lnÌ, musÌte vöak poËÌtat do budoucna s rozö̯enÌm sÌtÏ Ëi jin˝mi
˙pravami a kaûdÈ volnÈ ì U ì bude vÌt·no). K takto zÌskanÈmu souËtu
p¯i¯aÔte nejbliûöÌ vÏtöÌ velikost sk¯ÌnÏ. TÌm jste zÌskali optim·lnÌ v˝öku.
HodnÏ ˙spÏchu p¯i projektov·nÌ p¯eje firma MegaNET.
b) Mark down into the outline of a network cabinet above (divided into
individual "U" units) all equipment that you will need, i.e. patch-panels,
active equipment, UPS, fan units, blank filler and clamping panels,
19" shelves for fiber optic connectors, etc. Make sure you draw them in
the "U" units in the exact place in the cabinet. Always begin from the
bottom and work your way up to the top. By drawing out the layout in
this way, you will achieve the appropriate height. To this, add a sufficient
margin according to your will (this is very individual but you should not
fail to take into consideration a future network enlargement or other
space modifications when each free "U" position is welcome). Once you
have this final sum, find the nearest larger dimension of ZERAK network
cabinets. In this way you will determine the optimal height.
Good luck with your network design from MegaNET.
strana 40
Ol
om
ou
c
EXIT 201
Praha
Tu¯anka 107, 627 00 Brno
tel.: + 420 5 4521 8878
tel./fax: + 420 5 4521 8876
Czech Republic
Logo firmy MegaNET a
jsou registrovanÈ ochrannÈ zn·mky firmy Jan Klanica - MegaNET. Vöechna pr·va vyhrazena.
The MegaNET and